R313-15-302. Compliance with Dose Limits for Individual Members of the Public  


Latest version.
  • (1) The licensee or registrant shall make or cause to be made surveys of radiation levels in unrestricted and controlled areas and radioactive materials in effluents released to unrestricted and controlled areas to demonstrate compliance with the dose limits for individual members of the public in Section R313-15-301.

    (2) A licensee or registrant shall show compliance with the annual dose limit in Section R313-15-301 by:

    (a) Demonstrating by measurement or calculation that the total effective dose equivalent to the individual likely to receive the highest dose from the licensed or registered operation does not exceed the annual dose limit; or

    (b) Demonstrating that:

    (i) The annual average concentrations of radioactive material released in gaseous and liquid effluents at the boundary of the unrestricted area do not exceed the values specified in Table II of Appendix B of 10 CFR 20.1001 to 20.2402, (2010), which is incorporated by reference; and

    (ii) If an individual were continuously present in an unrestricted area, the dose from external sources would not exceed 0.02 mSv (0.002 rem) in an hour and 0.50 mSv (0.05 rem) in a year.

    (3) Upon approval from the Director, the licensee or registrant may adjust the effluent concentration values in Appendix B, Table II of 10 CFR 20.1001 to 20.2402, (2010), which is incorporated by reference, for members of the public, to take into account the actual physical and chemical characteristics of the effluents, such as, aerosol size distribution, solubility, density, radioactive decay equilibrium, and chemical form.