R746-210-2. Exemptions  


Latest version.
  • A. Automatic Exemptions -- Separate individual metering is not required for:

    1. Those portions of transient multiple occupancy buildings and transient mobile home parks normally used as temporary domiciles in such buildings as hotels, motels, dormitories, rooming houses, hospitals, nursing homes and those mobile home park sections designated for travel trailers;

    2. Residential unit space in multiple occupancy buildings where all space heating, water heating, ventilation and cooling are provided through central systems and where the electric load within each unit that is controlled by the tenant is projected to be 250 kWh or less per month and where the utility has been provided reasonable substantiation of the load projection;

    3. Common building areas such as hallways, elevators, reception and/or washroom, security lighting areas.

    4. Commercial unit space which is:

    a. Subject to alternation with change in tenants as evidenced by temporary as distinguished from permanent type of load bearing wall and floor construction separating the commercial unit spaces, and

    b. Non-energy intensive as evidenced by connected loads other than space heating, water heating, and air-conditioning of five watts or less per square foot of occupied space.