The treatment standard for many characteristic wastes is stated in the Section R315-268-40 Table of Treatment Standards as "Deactivation and meet UTS." The Director has determined that many technologies, when used alone or in combination, can achieve the deactivation portion of the treatment standard. Characteristic wastes that are not managed in a facility regulated by the Clean Water Act (CWA) or in a CWA-equivalent facility, and that also contain underlying hazardous constituents, see Subsection R315-268-2(i), shall be treated not only by a "deactivating" technology to remove the characteristic, but also to achieve the universal treatment standards (UTS) for underlying hazardous constituents. The following appendix presents a partial list of technologies, utilizing the five letter technology codes established in Section R315-268-42 Table 1, that may be useful in meeting the treatment standard. Use of these specific technologies is not mandatory and does not preclude direct reuse, recovery, and/or the use of other pretreatment technologies, provided deactivation is achieved and underlying hazardous constituents are treated to achieve the UTS.
Table
Waste code/subcategory Nonwastewaters Wastewaters
D001 Ignitable Liquids based on RORGS n.a.
R315-261-21(a)(1)-Low TOC INCIN
Nonwastewater Subcategory, WETOX
containing 1% to <10% TOC CHOXD
BIODG
D001 Ignitable Liquids based n.a. RORGS
on Subsection R315-261-21(a)(1) INCIN
-Ignitable Wastewater WETOX
Subcategory, containing <1% TOC CHOXD
BIODG
D001 Compressed Gases based RCGAS n.a.
on Subsection INCIN
R315-261-21(A)(3) FSUBS
ADGAS fb. INCIN
ADGAS fb. (CHOXD;
or CHRED)
D001 Ignitable Reactives WTRRX n.a.
based on CHOXD
Subsection R315-261-21(a)(2) CHRED
STABL
INCIN
D001 Ignitable Oxidizers CHRED CHRED
based on INCIN INCIN
Subsection R315-261-21(a)(4)
D002 Acid Subcategory RCORR NEUTR
based on NEUTR INCIN
Subsection R315-261-22(a)(1) INCIN
with pH less than or equal
to 2
D002 Alkaline Subcategory NEUTR NEUTR
based on INCIN INCIN
Subsection R315-261-22(a)(1)
with pH greater than or equal
to 12.5
D002 Other Corrosives based on CHOXD CHOXD
Subsection R315-261-22(a)(2) CHRED CHRED
INCIN INCIN
STABL
D003 Water Reactives based on INCIN n.a.
Subsections R315-268-23(a)(2), WTRRX
(3), and (4) CHOXD
CHRED
D003 Reactive Sulfides based CHOXD CHOXD
on Subsection R315-261-23(a)(5) CHRED CHRED
INCIN BIODG
STABL INCIN
D003 Explosives based on INCIN INCIN
Subsection R315-261-23(a)(6), CHOXD CHOXD
(7), and (8) CHRED CHRED
D003 Other Reactives based on INCIN INCIN
Subsection R315-261-23(a)(1) CHOXD CHOXD
CHRED CHRED
BIODG
CARBN
K044 Wastewater treatment CHOXD CHOXD
sludges from the manufacturing CHRED CHRED
and processing of explosives INCIN BIODG
CARBN
INCIN
K045 Spent carbon from the CHOXD CHOXD
treatment of wastewaters CHRED CHRED
containing explosives INCIN BIODG
CARBN
INCIN
K047 Pink/red water from TNT CHOXD CHOXD
operations CHRED CHRED
INCIN BIODG
CARBN
INCIN
Note: "n.a." stands for "not applicable"; "fb." stands for