R309-400-5. Quality, Monitoring and Public Notification Violations  


Latest version.
  •   (1) Total Coliform Rule: All points assessed to public water systems via this subsection are based on violations of the quality standards in R309-200-5(6); or the monitoring requirements in R309-210-5; and the associated public notification requirements in R309-220. The bacteriological points assessed shall be updated on a monthly basis with the total number of points reflecting the most recent twelve month period or the most recent 4 quarters for those water systems that collect bacteriological samples quarterly, unless otherwise noted.

      (a) For each major bacteriological routine monitoring violation, 35 points shall be assessed. For each failure to perform the associated public notification 5 points shall be assessed.

      (b) For each minor bacteriological routine monitoring violation, 10 points shall be assessed. For each failure to perform the associated public notification 2 points shall be assessed.

      (c) For each major bacteriological repeat monitoring violation, 40 points shall be assessed. For each failure to perform the associated public notification 5 points shall be assessed.

      (d) For each minor bacteriological repeat monitoring violation, 10 points shall be assessed. For each failure to perform the associated public notification 2 points shall be assessed.

      (e) For each additional monitoring violation (R309-210-5(2)(e)), 10 points shall be assessed. For each failure to perform the associated public notification 2 points shall be assessed.

      (f) For each non-acute bacteriological MCL violation (R309-200-5(6)(a)), 40 points shall be assessed. For each failure to perform the associated public notification 10 points shall be assessed.

      (g) For each acute bacteriological MCL violation (R309-200-5(6)(b)), 50 points shall be assessed. For each failure to perform the associated public notification 10 points shall be assessed.

      (2) Ground Water Rule: All points assessed to public water systems via this subsection are based on violations of the standards in R309-215-16. Points assessed for any significant deficiency shall be deleted as the deficiencies are corrected and are reported to the Director. The bacteriological points assessed shall be updated on a monthly basis with the total number of points reflecting the most recent 12-month period or the most recent four quarters for those water systems that collect bacteriological samples quarterly, unless otherwise noted.

      (a) For failure to collect triggered source samples in violation of R309-215-16(2)(a)(i)(A) and (a)(i)(B), 40 points shall be assessed. For each failure to perform the associated public notification, 2 points shall be assessed.

      (b) For failure to collect assessment source samples in violation of R309-215-16(2)(b)(i), 5 points shall be assessed. For each failure to perform the associated public notification, 2 points shall be assessed.

      (c) For failure to correct a significant deficiency in violation of R309-215-16(4)(a)(i) and (ii), R309-215-16(4)(c) or R309-215-16(4)(d), 35 points shall be assessed. For each failure to perform the associated public notification, 2 points shall be assessed.

      (d) For an Escherichia coli. in violation of R309-215-16(4)(b)(i) and (ii), 40 points shall be assessed. For each failure to perform the associated public notification, 2 points shall be assessed.

      (3) Chemical: All points assessed to public water systems via this subsection are based on violations of the quality standards in R309-200-5; or the monitoring requirements in R309-205, 210 and 215; and the associated public notification requirements in R309-220. The chemical assessments shall be updated on a quarterly basis with the total number of points reflecting the most recent compliance period unless otherwise specified. Points for any chemical MCL violation shall remain on record until the quality issue is resolved. Points for any monitoring violation shall be deleted as the required chemical samples are taken and the analytical results are reported to the Director.

      (a) Inorganic and Metal Contaminants:

      (i) For each major chemical monitoring violation for inorganic and metal contaminants, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for inorganic and metal contaminants, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) For each MCL exceedance for inorganic and metal contaminants, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (b) Sulfate (for non-community water systems only):

      (i) For each major chemical monitoring violation for sulfate, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for sulfate, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) For each MCL exceedance for sulfate, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (c) Radiologic Contaminants:

      (i) For each major chemical monitoring violation for radiological contaminants, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for radiological contaminants, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) For each MCL exceedance for radiological contaminants, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (d) Asbestos Contaminants:

      (i) For each major chemical monitoring violation for source water or distribution system asbestos, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for source water or distribution system asbestos, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) For each MCL exceedance for source water or distribution system asbestos, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (e) Nitrate:

      (i) For each routine chemical monitoring violation for nitrate, 50 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (ii) For each MCL exceedance of nitrate, 60 points shall be assessed. For each failure to perform the associated public notification, 10 points shall be assessed.

      (f) Nitrite:

      (i) For each routine chemical monitoring violation for nitrite, 35 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (ii) For each MCL exceedance of nitrite, 50 points shall be assessed. For each failure to perform the associated public notification, 10 points shall be assessed.

      (g) Volatile Organic Chemicals:

      (i) For each major chemical monitoring violation for volatile organic chemical contaminants, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for volatile organic chemical contaminants, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) For each MCL exceedance for volatile organic chemical contaminants, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (h) Pesticides/PCBs/SOCs

      (i) For each major chemical monitoring violation for pesticide/PCB/SOC contaminants, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for pesticide/PCB/SOC contaminants, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) For each MCL exceedance for pesticide/PCB/SOC contaminants, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (i) Disinfection Byproducts:

      (i) Total Trihalomethanes:

      (A) For each routine chemical monitoring violation for total trihalomethanes, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each MCL exceedance for total trihalomethanes, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (ii) Haloacetic Acids (HAA5):

      (A) For each routine chemical monitoring violation for HAA5, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each MCL exceedance for HAA5, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (iii) Bromate:

      (A) For each routine chemical monitoring violation for bromate, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each MCL exceedance for bromate, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (iv) Chlorite:

      (A) For each routine chemical monitoring violation for chlorite, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each MCL exceedance for chlorite, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (j) Disinfectant Residuals:

      (i) Chlorine:

      (A) For each routine chemical monitoring violation for chlorine, 10 points shall be assessed. R309-210-8(3)(a). For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each MCL exceedance for chlorine, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (C) For a disinfected system that does not maintain a trace residual at all points of the distribution system, 2 points shall be assessed. R309-105-10(1) and R309-200-5(7).

      (D) For a disinfected system that lacks an adequate number of disinfection residual sample sites, 2 points shall be assessed. R309-210-8(3)(a)(i)(z15).

      (ii) Chloramines:

      (A) For each routine chemical monitoring violation for chloramines, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each MCL exceedance for chloramines, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (iii) Chlorine Dioxide:

      (A) For each routine monitoring violation for chlorine dioxide, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (B) For each non-acute chlorine dioxide MCL violation, 30 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (C) For each acute chlorine dioxide MCL violation, 50 points shall be assessed. For each failure to perform the associated public notification, 10 points shall be assessed.

      (iv) Ground Water Rule, where a water system has received a 4-Log exemption from triggered source water monitoring:

      (A) For a ground water treatment facility serving greater than 3300 population lacking equipment to measure chlorine residuals continuously entering the distribution system, 20 points shall be assessed. R309-215-10(1).

      (B) For a ground water system serving greater than 3300 people failing to continuously monitor the residual disinfectant concentrations, 10 points shall be assessed. R309-215-16(3)(b)(iii)(A)(I).

      (C) For a ground water system serving less than 3300 people failing to collect a daily grab sample during peak demand to monitor the residual disinfectant concentrations, 10 points shall be assessed. R309-215-16(3)(b)(iii)(A)(II).

      (D) For a ground water system that during the past year, the disinfection process was not operated uninterrupted while water was being produced, points will be assessed based on monthly and quarterly treatment reports. R309-200-5(7).

      (E) For a ground water system that is required to provide continuous disinfection but fails to do so, 10 points shall be assessed for each month the failure continues. R309-520-6(1).

      (k) Lead and Copper:

      (i) For each major chemical monitoring violation for lead and copper contaminants, 20 points shall be assessed. For each failure to perform the associated public notification, 3 points shall be assessed.

      (ii) For each minor chemical monitoring violation for lead and copper contaminants, 10 points shall be assessed. For each failure to perform the associated public notification, 1 point shall be assessed.

      (iii) A system that fails to install, by the designated deadline, optimal corrosion control if the lead or copper action level has been exceeded shall be assessed 35 points. For each failure to perform the associated public notification, 10 point shall be assessed.

      (iv) A system that fails to install source water treatment if the source waters exceed the lead or copper action level shall be assessed 35 points. For each failure to perform the associated public notification, 10 points shall be assessed.

      (v) A system that fails to complete public notification/education if the lead/copper action levels have been exceeded shall be assessed 10 points for each calendar quarter that the system fails to provide public notification/education.

      (vi) A system that still exceeds the lead action level and is not on schedule for lead line replacement shall be assessed 5 points annually. For each failure to perform the associated public notification, 2 point shall be assessed.

      (vii) A system that fails to notify its customers of their lead and copper sample results, 5 points shall be assessed.

      (viii) A system that fails to send the lead and copper certification notice to the Division, 5 points shall be assessed.

      (l) Groundwater Turbidity:

      (i) For each monitoring violation for turbidity, 35 points shall be assessed. For each failure to perform the associated public notification, 5 points shall be assessed.

      (ii) For each confirmed MCL exceedance of turbidity, 50 points shall be assessed. For each failure to perform the associated public notification, 10 points shall be assessed.

      (m) Surface Water Treatment:

      (i) For water systems having sources, which are classified as under direct influence from surface water and which fail to abandon, retrofit or provide conventional complete treatment or its equivalent within 18 months of notification shall be assessed 150 points. For the associated failure to perform public notification 10 points shall be assessed. The points shall be assessed as the failure occurs and shall remain on record until adequate treatment is provided or the source is physically disconnected.

      (ii) Quality and Monitoring: The surface water treatment assessments shall be updated on a monthly basis with the total number of points reflecting the most recent 12-month period.

      (A) Turbidity:

      (I) For each turbidity exceedance that requires tier 1 notification under R309-220-5(1)(e) or (f), 50 points shall be assessed. For the associated failure to perform public notification, 10 points shall be assessed.

      (II) For each turbidity exceedance that requires tier 2 notification under R309-220-5(1)(e) or (f), 35 points shall be assessed. For the associated failure to perform public notification, 10 points shall be assessed.

      (III) For each month where the percentage of turbidity interpretations meeting the treatment plant limit is less than 95 percent, 25 points shall be assessed. For the associated failure to perform public notification, 10 points shall be assessed.

      (IV) For any period of time that exceeds 4 hours where the system fails to continuously measure (or perform grab samples) the combined filter effluent turbidity, 50 points shall be assessed. For the associated failure to perform public notification, 10 points shall be assessed.

      (V) For a water system whose failure to repair continuous turbidity monitoring equipment within 5 working days, 50 points shall be assessed.

      (B) Disinfection:

      (I) For each instance where the disinfectant level in water entering the distribution system is less than 0.2 milligrams per liter for more than 4 hours, 25 points shall be assessed. For the associated failure to perform public notification, 5 points shall be assessed.

      (II) For each instance where there is insufficient disinfectant contact time, 35 points shall be assessed. For the associated failure to perform public notification, 5 points shall be assessed.

      (iii) Treatment Process Control:

      (A) For each instance a treatment facility exceeds the assigned filter rates, 30 points shall be assessed.

      (B) For each month a water system fails to verify calibration of the plant turbidimeters, 5 points shall be assessed.

      (C) For each month a water system fails to submit a water treatment plant report, 50 points shall be assessed.