Utah Administrative Code (Current through November 1, 2019) |
R307. Environmental Quality, Air Quality |
R307-350. Miscellaneous Metal Parts and Products Coatings |
R307-350-5. VOC Content Limits
-
(1) No owner or operator shall apply coatings with a VOC content greater than the amounts specified in Table 1, unless the owner or operator uses an add-on control device as specified in R307-350-8.
TABLE 1
METAL PARTS AND PRODUCTS VOC CONTENT LIMITS
(values in pounds of VOC per gallon of coating, minus water and
exempt solvents (compounds not classified as VOC as defined in
R307-101-2), as applied)
Coating Category VOC Content Limits (lb/gal)
Air Dried Baked
General One Component 2.8 2.3
General Multi Component 2.8 2.3
Camouflage 3.5 3.5
Electric-Insulating 3.5 3.5
varnish
Etching Filler 3.5 3.5
Extreme High-Gloss 3.5 3.0
Extreme Performance 3.5 3.0
Heat-Resistant 3.5 3.0
High-Performance 6.2 6.2
architectural
High-Temperature 3.5 3.5
Metallic 3.5 3.5
Military Specification 2.8 2.3
Mold-Seal 3.5 3.5
Pan Backing 3.5 3.5
Prefabricated Architectural 3.5 2.3
Multi-Component
Prefabricated Architectural 3.5 2.3
One-Component
Pretreatment Coatings 3.5 3.5
Repair and Touch Up 3.5 3.0
Silicone Release 3.5 3.5
Solar-Absorbent 3.5 3.0
Vacuum-Metalizing 3.5 3.5
Drum Coating, New, Exterior 2.8 2.8
Drum Coating, New, Interior 3.5 3.5
Drum Coating, Reconditioned, 3.5 3.5
Exterior
Drum Coating, Reconditioned, 4.2 4.2
Interior
(2) If more than one content limit indicated in this section applies to a specific coating, then the most stringent content limit shall apply.