R313-15-602. Control of Access to Very High Radiation Areas  


Latest version.
  • (1) In addition to the requirements in Section R313-15-601, the licensee or registrant shall institute measures to ensure that an individual is not able to gain unauthorized or inadvertent access to areas in which radiation levels could be encountered at five Gy (500 rad) or more in one hour at one meter from a source of radiation or any surface through which the radiation penetrates. This requirement does not apply to rooms or areas in which diagnostic x-ray systems are the only source of radiation, or to non-self-shielded irradiators.

    (2) The registrant is not required to control entrance or access to rooms or other areas containing sources of radiation capable of producing a very high radiation area as described in Subsection R313-15-602(1) if the registrant has met all the specific requirements for access and control specified in other applicable sections of these rules, such as, Rule R313-36 for industrial radiography, Rule R313-28 for x rays in the healing arts, Rule R313-30 for therapeutic radiation machines, and Rule R313-35 for industrial use of x-ray systems.