R616-3-9. Valves in Hydraulic Elevator Operating Fluid Systems  


Latest version.
  • A. Due to the potential loss of pressure retaining capability when over torqued, bronze-bodied valves shall not be installed in the hydraulic systems of a hydraulic elevator.

    B. This requirement is in effect for all new installations and remodel installations involving the hydraulic system.

    C. If a bronze-bodied valve installed on an existing elevator begins to leak, that valve shall be replaced by a steel-bodied valve.