Utah Administrative Code (Current through November 1, 2019) |
R616. Labor Commission, Boiler, Elevator and Coal Mine Safety |
R616-3. Elevator Rules |
R616-3-9. Valves in Hydraulic Elevator Operating Fluid Systems
Latest version.
-
A. Due to the potential loss of pressure retaining capability when over torqued, bronze-bodied valves shall not be installed in the hydraulic systems of a hydraulic elevator.
B. This requirement is in effect for all new installations and remodel installations involving the hydraulic system.
C. If a bronze-bodied valve installed on an existing elevator begins to leak, that valve shall be replaced by a steel-bodied valve.