R317-3-12. Effluent Filtration


Latest version.
  • 12.1. Granular Media Filters. Granular media filters may be used as a tertiary treatment device for the removal of residual suspended solids from secondary effluents. A pretreatment process such as chemical coagulation and sedimentation or other acceptable process must precede the filter units, where effluent suspended solids requirements are less than 10 milligrams per liter, or where secondary effluent quality can be expected to fluctuate significantly, or where filters follow a treatment process and where significant amounts of algae will be present.

    12.2. Design Considerations. The plant design should incorporate flow-equalization facilities to moderate filter influent quality and quantity. The selection of pumping equipment ahead of filter units should be designed to minimize shearing of floc particles.

    A. Filter Types. Filters may be of the gravity or pressure type. Pressure filters shall be provided with ready and convenient access to the media for treatment or cleaning. Where greases or similar solids which result in filter plugging are expected, filters should be of the gravity type.

    B. Filtration Rates. Filtration rates shall not exceed 5 gallons per minute per square foot. (3.4 liters per square meter per second) based on the maximum hydraulic flow rate applied to the filter units.

    C. Number of Units. Total filter area shall be provided in two or more units, and the filtration rate shall be calculated on the total available filter area with one unit out of service.

    D. Filter Backwash

    1. Backwash Rate. The backwash rate shall be adequate to fluidize and expand each media layer a minimum of 20 percent based on the media selected. The backwash system shall be capable of providing a variable backwash rate having a maximum of at least 20 gallons per minute per square foot, (13.6 liters per square meter per second) and a minimum backwash period of 10 minutes.

    2. Backwash Pumps. Pumps for backwashing filter units shall be sized and interconnected to provide the required rate to any filter with the largest pump out of service. Filtered water should be used as the source of backwash water. Waste filter backwash shall be returned to the treatment process or otherwise adequately treated.

    E. Filter Media

    1. Selection. Selection of proper media size will depend on the rate of filtration rate, the type of pretreatment, filter configuration, and effluent quality objectives. In dual or multi-media filters, media size selection must consider compatibility among media.

    2. Media Specifications. Table R317-3-12.2(E)(2) provides minimum media depths and the normally acceptable range of media sizes. The applicant has the responsibility for selection of media to meet specific conditions and treatment requirements relative to the project under consideration.

    12.3. Filter Appurtenances. The filters shall be equipped with wash water troughs, surface wash or air scouring equipment, means of measurement and positive control of the backwash rate, equipment for measuring filter head loss, positive means of shutting off flow to a filter being backwashed, and filter influent and effluent sampling points. If automatic controls are provided, there shall be a manual override for operating equipment, including each individual valve essential to the filter operation. The underdrain system shall be designed for uniform distribution of backwash water (and air if provided) without danger of clogging from solids in the backwash water. Provision shall be made to allow periodic chlorination of the filter influent or backwash water to control slime growths.

    12.4. Reliability. Each filter unit shall be designed and installed so that there is ready and convenient access to all components and the media surface for inspection and maintenance without taking other units out of service. The need for enclosing filter units shall depend on expected extreme climatic conditions at the treatment plant site. As a minimum, all controls shall be protected from adverse process and climatic conditions. The structure housing filter controls and equipment shall be provided with adequate heating and ventilation equipment to minimize problems with excess humidity.

    12.5. Backwash Surge Control. The rate of waste filter backwash water return to treatment units shall be controlled such that the rate does not exceed 15 percent of the design average daily flow rate to the treatment units. The hydraulic and organic loads from waste backwash water shall be considered in the overall design of the treatment plant. Where waste backwash water is returned for treatment by pumping, adequate pumping capacity shall be provided with the largest unit out of service.

    12.6. Backwash Water Storage. Total backwash water storage capacity provided in an effluent clearwell or surge tank or other unit shall equal or exceed the volume required for two complete backwash cycles. Additional storage capacity should be considered for operational flexibility.

    12.7. Proprietary Equipment. Where proprietary filtration equipment, not conforming to the preceding requirements is proposed, data which supports the capacity of the equipment to meet effluent requirements under design conditions shall be submitted for review and approval by the Director.


    TABLE R317-3-2.3(D)(4).

    Minimum Slopes


          Sewer Size, Minimum Slope,

          inch (centimeter) feet per feet or

                                      meter per meter


                 8 (20) 0.00334

                 9 (23) 0.00285

                10 (25) 0.00248

                12 (30) 0.00194

                14 (36) 0.00158

                15 (38) 0.00144

                16 (41) 0.00132

                18 (46) 0.00113

                21 (53) 0.00092

                24 (61) 0.00077

                27 (69) 0.00066

                30 (76) 0.00057

                36 (91) 0.00045



    TABLE R317-3-4.4(H)(1).

    Painting


          Service Color


          Sludge Brown


          Gas Orange


          Potable Water Blue


          Non-Potable Water Blue with a 6-inch (15 centimeters)

                                red band spaced 30 inches

                                (76 centimeters) apart


          Chlorine Yellow


          Compressed Air Green


          Sewage Gray



    TABLE R317-3-6.2(B)(3)(d).

    Loadings for Final Settling Tanks

    Following Activated Sludge Process


        Process Average Surface Surface

                        Design Loading, Loading,

                        Rate of gallons per pounds

                        Flow, day per day

                        million per square per square

                        gallons foot foot

                        per day (cubic (kilograms

                        (cubic meters per day

                        meters per day per square

                        per day) per square meter)

                                         meter)


        Contact 0.5 (1,893) 400 (16.3)

        Stabilization to 1.5 to 600

                        (5,678) (24.5)


                        Greater than 500 (20.4)

                        or equal to to 700

                        1.5 (5,678) (28.5)


        Extended Less than 200 (8.2)

        Aeration or equal to to 400

                        0.5 (1,893) (16.3)


                        0.5 (1,893) 300 (12.3) 25 (122.1)

                        to 1.5 to 500

                        (5,678) (20.4)


                        Greater than 400 (16.3)

                        or equal to to 600

                        1.5 (5,678) (24.5)


        Other than Less than 400 (16.3)

        Contact or equal to to 600

        Stabilization 0.5 (1,893) (24.5)

        and Extended

        Aeration 0.5 (1,893) to 500 (20.4) 25 (122.1)

                        1.5 (5,678) to 700 (28.5)


                        Greater than 600 (24.5)

                        or equal to to 800

                        1.5 (5,678) (32.6)



    TABLE R317-3-7.1(E)(3)(a)(2).

    Media Grading


                                                     Percent by

                                                       Weight


    Passing 4-1/2 inch (11.4 centimeters) screen 100


    Retained on 3 inch (7.6 centimeters) screen 95 - 100


    Retained on 2 inch (5.1 centimeters) screen 98



    TABLE R317-3-7.1(K)(1).

    Hydraulic and Organic Loadings

    for Nitrification in Trickling Filters


     Trickling Filter Configuration Loadings


     Rock or Slag Media Filters


          Hydraulic Loading Less than or equal

                                           to 4 million gallons

                                           per acre per day, or

                                           less than or equal

                                           to 4 cubic meters

                                           per square meter per

                                           day


          Organic Loading Less than or equal

                                           to 25 pounds BOD5

                                           per day per 1000

                                           cubic feet, or

                                           less than or equal

                                           to 0.4 kilograms

                                           BOD5 per day per

                                           cubic meter


     Deep Manufactured Media Filters


          Hydraulic Loading Less than or equal

                                           to 25 million

                                           gallons per acre per

                                           day, or less than or

                                           equal to 25 cubic

                                           meters per square

                                           meter per day


          Organic Loading Less than or equal to 100

                                           pounds BOD5 per day per

                                           1000 cubic feet, or less

                                           than or equal to

                                           1.6 kilograms BOD5

                                           per day per cubic meter



    TABLE R317-3-7.2(B)(1)(c)

    Permissible Aeration Tank Capacities and Loadings


    Process Hydraulic Solids Aeration Food:Mass Mixed

               Retention Retention Tank (F:M) Liquor

               Time Time Loading, Ratio, Suspended

               (HRT), (SRT), pounds of pounds of Solids (1)

               hours days BOD5 per BOD5 per (MLSS)

                                      day per day per milligrams

                                      1000 pound of per liter

                                      cubic MLVSS (2)

                                      feet


    Conven- 4-8 4-8 20-40 0.2-0.4 1,500-

    tional 4,000


    Step

    Aeration


    Complete

    Mix


    Contact 1-3 (4) 3-10 50 (3) 0.2-0.6 2,000-

    Stabili- 3-6 (5) 4,000

    zation


    Extended

    Aeration,

    or 24 30 10-12 0.05- 2,000-

    Oxidation 0.1 4,000

    Ditch


         Notes:

         (1) Mixed Liquor Suspended Solids (MLSS) values are

    dependent upon the surface area provided for sedimentation and

    the rate of sludge return as well as the aeration process.

         (2) Mixed Liquor Volatile Suspended Solids (MLVSS)

         (3) Total Aeration capacity, includes both contact and

    reaeration capacities. Normally, the contact zone equals 30 to

    35 percent of the total aeration capacity.

         (4) Contact zone

         (5) Reaeration zone



    TABLE R317-3-7.2(B)(6)(a)(1).

    Return Sludge Rate


          Process QR / Q, Percent


          Standard Rate 15-75


          Carbonaceous stage

          of separate stage nitrification 15-75


          Step Aeration 15-75


          Contact stabilization 50-150


          Extended aeration 50-150


          Nitrification stage of

          separate stage nitrification 50-200



    TABLE R317-3-9.3(A)(1)(a).

    Gravity Thickening


    Type Solids Loading Rate, Percent solids

                              pounds per day per in thickened

                              square foot (kilograms sludge

                              per square meter

                              per day)


    Primary sludge 20-30 (98-146) 8-10


    Trickling filter sludge 8-10 (39-49) 7-9


    Activated sludge 4-8 (20-49) 2.5-3


    Combined primary and

    trickling filter

    sludges 10-12 (49-59) 7-9


    Combined primary and

    activated sludges 6-10 (29-49) 3-6



    TABLE R317-3-9.4(A)(4)(a).

    Sludge Volume Generated


          Type of Plant cubic feet per Population

                                           Equivalent (P.E.) or cubic

                                           meters per Population

                                           Equivalent (P.E.)


          Trickling Filter 5 (0.14)


          Activated Sludge 6 (0.17)



    TABLE R317-3-10.3(G)(3)(a).

    Circle of Influence


          Nameplate Horsepower Radius, Feet


                     5 35


                     10-25 50


                     40-60 50-100


                     75 60-100


                     100 100



    TABLE R317-3-12.2(E)(2).

    Media Depths and Size


    Media Material Single Media Multi-Media

                                                    Two Three


    Anthracite:

        Minimum Depth, inches 20 20

        Effective Size, millimeters 1-2 1-2

    Sand:

        Minimum Depth, inches 48 12 10

        Effective Size, millimeters 1-4 0.5-1 0.6-0.8


    Garnet or Similar Material:

        Minimum Depth, inches 2

        Effective Size, millimeters 0.3-0.6


         Uniformity Coefficient shall be less than or equal to 1.7