Except as otherwise provided in Section R315-264-1, owners and operators of facilities that dispose of hazardous waste in landfills shall provide the following additional information:
(a) A list of the hazardous wastes placed or to be placed in each landfill or landfill cell;
(b) Detailed plans and an engineering report describing how the landfill is designed and is or will be constructed, operated, and maintained to meet the requirements of Sections R315-264-19 and Sections R315-264-301 through 303, addressing the following items:
(1)(i) The liner system, except for an existing portion of a landfill, if the landfill shall meet the requirements of Subsection R315-264-301(a). If an exemption from the requirement for a liner is sought as provided by Subsection R315-264-301(b), submit detailed plans, and engineering and hydrogeological reports, as appropriate, describing alternate designs and operating practices that shall, in conjunction with location aspects, prevent the migration of any hazardous constituents into the ground water or surface water at any future time;
(ii) The double liner and leak, leachate; detection; collection; and removal system; if the landfill shall meet the requirements of Subsection R315-264-301(c). If an exemption from the requirements for double liners and a leak detection, collection, and removal system or alternative design is sought as provided by Subsection R315-264-301(d), (e), or (f), submit appropriate information;
(iii) If the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation, and the location of the saturated zone in relation to the leak detection system;
(iv) The construction quality assurance (CQA) plan if required under Section R315-264-19;
(v) Proposed action leakage rate, with rationale, if required under Section R315-264-302, and response action plan, if required under Section R315-264-303;
(2) Control of run-on;
(3) Control of run-off;
(4) Management of collection and holding facilities associated with run-on and run-off control systems; and
(5) Control of wind dispersal of particulate matter, where applicable;
(c) A description of how each landfill, including the double liner system, leachate collection and removal system, leak detection system, cover system, and appurtenances for control of run-on and run-off, will be inspected in order to meet the requirements of Subsections R315-264-303(a), (b), and (c). This information shall be included in the inspection plan submitted under Subsection R315-270-14(b)(5);
(d) A description of how each landfill, including the liner and cover systems, will be inspected in order to meet the requirements of Subsections R315-264-303(a) and (b). This information should be included in the inspection plan submitted under Subsection R315-270-14(b)(5).
(e) Detailed plans and an engineering report describing the final cover which will be applied to each landfill or landfill cell at closure in accordance with Subsection R315-264-310(a), and a description of how each landfill will be maintained and monitored after closure in accordance with Subsection R315-264-310(b). This information should be included in the closure and post-closure plans submitted under Subsection R315-270-14(b)(13).
(f) If ignitable or reactive wastes will be landfilled, an explanation of how the standards of Section R315-264-312 will be complied with;
(g) If incompatible wastes, or incompatible wastes and materials will be landfilled, an explanation of how Section R315-264-313 will be complied with;
(h) If bulk or non-containerized liquid waste or wastes containing free liquids is to be landfilled prior to May 8, 1985, an explanation of how the requirements of Subsection R315-264-314(a) will be complied with;
(i) If containers of hazardous waste are to be landfilled, an explanation of how the requirements of Section R315-264-315 or Section R315-264-316, as applicable, will be complied with.
(j) A waste management plan for EPA Hazardous Waste Nos. FO20, FO21, FO22, FO23, FO26, and FO27 describing how a landfill is or will be designed, constructed, operated, and maintained to meet the requirements of Section R315-264-317. This submission shall address the following items as specified in Section R315-264-317:
(1) The volume, physical, and chemical characteristics of the wastes, including their potential to migrate through soil or to volatilize or escape into the atmosphere;
(2) The attenuative properties of underlying and surrounding soils or other materials;
(3) The mobilizing properties of other materials co-disposed with these wastes; and