R315-264-1032. Standards: Process Vents  


Latest version.
  •   (a) The owner or operator of a facility with process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operations managing hazardous wastes with organic concentrations of at least 10 ppmw shall either:

      (1) Reduce total organic emissions from all affected process vents at the facility below 1.4 kg/h (3 lb/h) and 2.8 Mg/yr (3.1 tons/yr), or

      (2) Reduce, by use of a control device, total organic emissions from all affected process vents at the facility by 95 weight percent.

      (b) If the owner or operator installs a closed-vent system and control device to comply with the provisions of Subsection R315-264-1032(a) the closed-vent system and control device shall meet the requirements of Section R315-264-1033.

      (c) Determinations of vent emissions and emission reductions or total organic compound concentrations achieved by add-on control devices may be based on engineering calculations or performance tests. If performance tests are used to determine vent emissions, emission reductions, or total organic compound concentrations achieved by add-on control devices, the performance tests shall conform with the requirements of Subsection R315-264-1034(c).

      (d) When an owner or operator and the Director do not agree on determinations of vent emissions and/or emission reductions or total organic compound concentrations achieved by add-on control devices based on engineering calculations, the procedures in Subsection R315-264-1034(c) shall be used to resolve the disagreement.