R315-15. Standards for the Management of Used Oil  


R315-15-1. Applicability, Prohibitions, and Definitions
Latest version.

  1.1 APPLICABILITY

  This section identifies those materials that are subject to regulation as used oil under R315-15. This section also identifies some materials that are not subject to regulation as used oil under R315-15, and indicates whether these materials may be a hazardous waste as defined under R315-261.

  (a) Used oil. It is presumed that used oil is to be recycled unless a used oil handler disposes of used oil or sends used oil for disposal. Except as provided in R315-15-1.2, the requirements of R315-15 apply to used oil, and to materials identified in this section as being subject to regulation as used oil, whether or not the used oil or material exhibits any characteristics of hazardous waste identified in R315-261-20 through 24.

  (b) Mixtures of used oil and hazardous waste.

  (1) Listed hazardous waste.

  (i) Mixtures of used oil and hazardous waste which are listed in R315-261-30 through 33 and 35 are subject to regulation as hazardous waste under R315-261 rather than as used oil under R315-15.

  (ii) Rebuttable presumption for used oil. Used oil containing more than 1,000 ppm total halogens is presumed to be a hazardous waste because it has been mixed with halogenated hazardous waste listed in R315-261-30 through 33 and 35. A person may rebut this presumption by demonstrating that the used oil does not contain hazardous waste, for example, by using an analytical method from SW-846, Edition III, Update IV to show that the used oil does not contain significant concentrations of halogenated hazardous constituents listed in R315-261, Appendix VIII.

  (A) The rebuttable presumption does not apply to metalworking oils/fluids containing chlorinated paraffins, if they are processed, through a tolling arrangement as described in R315-15-2.5(c), to reclaim metalworking oils/fluids. The presumption does apply to metalworking oils/fluids if such oils/fluids are recycled in any other manner, or disposed.

  (B) The rebuttable presumption does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units where the CFCs are destined for reclamation. The rebuttable presumption does apply to used oils contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units.

  (2) Characteristic hazardous waste. A mixture of used oil and hazardous waste that solely exhibits one or more of the hazardous waste characteristics identified in R315-261-20 through 24 and a mixtures of used oil and hazardous waste that is listed in R315-261-30 through 33 and 35 solely because it exhibits one or more of the characteristics of hazardous waste identified in R315-261-20 through 24 are subject to:

  (i) Except as provided in R315-15-1(b)(2)(iii), regulation as hazardous waste under R315-260 through 266, 268, 270, and 273 rather than as used oil under R315-15, if the resultant mixture exhibits any characteristics of hazardous waste identified in R315-261-20 through 24; or

  (ii) Except as specified in R315-15-1.1(b)(2)(iii), regulation as used oil under R315-15, if the resultant mixture does not exhibit any characteristics of hazardous waste identified under R315-261-20 through 24.

  (iii) Regulation as used oil under R315-15, if the mixture is of used oil and a waste which is hazardous solely because it exhibits the characteristic of ignitability, e.g., mineral spirits, provided that the mixture does not exhibit the characteristic of ignitability under R315-261-21.

  (3) Very small quantity generator hazardous waste. Mixtures of used oil and very small quantity generator hazardous waste regulated under Section R315-262-14 are subject to regulation as used oil under R315-15.

  (c) Materials containing or otherwise contaminated with used oil.

  (1) Except as provided in R315-15-1.1(c)(2) materials containing or otherwise contaminated with used oil from which the used oil has been properly drained or removed to the extent possible such that no visible signs of free-flowing oil remain in or on the material:

  (i) Are not used oil and thus not subject to R315-15, and

  (ii) If applicable, are subject to the hazardous waste regulations R315-260 through 266, 268, 270, and 273, and R315-101 and 102.

  (2) Materials containing or otherwise contaminated with used oil that are burned for energy recovery are subject to regulation as used oil under R315-15.

  (3) Used oil drained or removed from materials containing or otherwise contaminated with used oil is subject to regulation as used oil under R315-15.

  (d) Mixtures of used oil with products.

  (1) Except as provided in (d)(2) mixtures of used oil and fuels or other fuel products are subject to regulation as used oil under R315-15.

  (2) Mixtures of used oil and diesel fuel mixed on site by the generator of the used oil for use in the generator's own vehicles are not subject to R315-15 after the used oil and diesel fuel have been mixed. Prior to mixing, the used oil is subject to the requirements of R315-15-2.

  (e) Materials derived from used oil.

  (1) Materials that are reclaimed from used oil that are used beneficially and are not burned for energy recovery or used in a manner constituting disposal, e.g., re-refined lubricants, are:

  (i) Not used oil and thus are not subject to R315-15, and

  (ii) Not solid wastes and are thus not subject to the hazardous waste regulations of R315-260 through 266, 268, 270, and 273 as provided in R315-261-3(c)(2)(i).

  (2) Materials produced from used oil that are burned for energy recovery, e.g., used oil fuels, are subject to regulation as used oil under R315-15.

  (3) Except as provided in R315-15.1.1(e)(4), materials derived from used oil that are disposed of or used in a manner constituting disposal are:

  (i) Not used oil and thus are not subject to R315-15, and

  (ii) Are solid wastes and thus are subject to the hazardous waste regulations R315-260 through 266, 268, 270, and 273 if the materials are listed or identified as hazardous wastes.

  (4) Used oil re-refining distillation bottoms that are used as feedstock to manufacture asphalt products are not subject to R315-15.

  (f) Wastewater. Wastewater contaminated with de minimis quantities of used oil, the discharge of which is subject to regulation under either section 402 or section 307(b) of the Clean Water Act, including wastewaters at facilities that have eliminated the discharge of wastewater, are not subject to the requirements of Rule R315-15. For purposes of this paragraph only, "de minimis" quantities of used oils are defined as small spills, leaks, or drippings from pumps, machinery, pipes, and other similar equipment during normal operations or small amounts of oil lost to the wastewater treatment system during washing or draining operations. This exception does not apply if the used oil is discarded as a result of abnormal manufacturing operations resulting in substantial leaks, spills, or other releases, or to used oil recovered from wastewaters.

  (g) Used oil introduced into crude oil pipelines or a petroleum refining facility.

  (1) Used oil mixed with crude oil or natural gas liquids, e.g., in a production separator or crude oil stock tank, for insertion into a crude oil pipeline is exempt from the requirements of R315-15. The used oil is subject to the requirements of R315-15 prior to the mixing of used oil with crude oil or natural gas liquids.

  (2) Mixtures of used oil and crude oil or natural gas liquids containing less than 1% used oil that are being stored or transported to a crude oil pipeline or petroleum refining facility for insertion into the refining process at a point prior to crude distillation or catalytic cracking are exempt from the requirements of R315-15.

  (3) Used oil that is inserted into the petroleum refining facility process before crude distillation or catalytic cracking without prior mixing with crude oil is exempt from the requirements of R315-15, provided that the used oil constitutes less than 1% of the crude oil feed to any petroleum refining facility process unit at any given time. Prior to insertion into the petroleum refining facility process, the used oil is subject to the requirements of R315-15.

  (4) Except as provided in R315-15-1.1 (g)(5), used oil that is introduced into a petroleum refining facility process after crude distillation or catalytic cracking is exempt from the requirements of R315-15 only if the used oil meets the specification of R315-15-1.2. Prior to insertion into the petroleum refining facility process, the used oil is subject to the requirements of R315-15.

  (5) Used oil that is incidentally captured by a hydrocarbon recovery system or wastewater treatment system as part of routine process operations at a petroleum refining facility and inserted into the petroleum refining facility process is exempt from the requirements of R315-15. This exemption does not extend to used oil that is intentionally introduced into a hydrocarbon recovery system, e.g., by pouring collected used oil into the waste water treatment system.

  (6) Tank bottoms from stock tanks containing exempt mixtures of used oil and crude oil or natural gas liquids are exempt from the requirements of R315-15.

  (h) Used oil on vessels. Used oil produced on vessels from normal shipboard operations is not subject to Rule R315-15 until it is transported ashore.

  (i) Used oil containing PCBs. In addition to the requirements of R315-15, marketers and burners of used oil who market used oil containing PCBs at concentrations greater than or equal to 2 ppm are subject to the requirements found in R315-15-18 and 40 CFR 761.20(e).

  (j) Inspections. Any duly authorized employee of the Director, may, at any reasonable time and upon presentation of credentials, have access to and the right to copy any records relating to used oil, and inspect, audit, or sample. Any authorized employee obtaining samples shall give to the owner, operator or agent a receipt describing the sample obtained and, if requested, a portion of each sample of waste equal in volume or weight to the portion retained. The employee may also make record of the inspection by photographic, electronic, audio, video, or any other reasonable means.

  (k) Violations, Orders, and Hearings. If the Director has reason to believe a person is in violation of any provision of R315-15, procedural requirements for compliance shall follow Utah Code Annotated 19-6-721 and Utah Administrative Code R305-7.

  1.2 USED OIL SPECIFICATIONS

  Used oil burned for energy recovery, and any fuel produced from used oil by processing, blending, or other treatment, is subject to regulation under R315-15 until:

  (a) It has been demonstrated not to exceed any allowable levels of the constituents and properties shown in Table 1;

  (b) The person making that claim complies with R315-15-7.3, R315-15-7.4, and R315-15-7.5(b); and

  (c) The used oil is delivered to a used oil burner.


TABLE 1

USED OIL NOT EXCEEDING ANY ALLOWABLE LEVEL IS NOT

SUBJECT TO R315-15-6 WHEN BURNED FOR ENERGY RECOVERY(1)

     Constituent/property Allowable level


       Arsenic 5 ppm maximum

       Cadmium 2 ppm maximum

       Chromium 10 ppm maximum

       Lead 100 ppm maximum

       Flash point 100 degrees F minimum

       Total halogens 4,000 ppm maximum(2)


     (1) The allowable levels in Table 1 do not apply to

mixtures of used oil and hazardous waste that continue to beregulated as hazardous waste. See R315-15-1.1(b).

     (2) Used oil containing more than 1,000 ppm total halogens

is presumed to be a hazardous waste under the rebuttable

presumption described in R315-15-1.1(b)(1). Such used oil is

subject to R315-266-100 through 112, rather than R315-15 when

burned for energy recovery unless the presumption of mixing can

be successfully rebutted.

     Note: Applicable standards for the marketing and burning

of used oil containing any quantifiable level (2 ppm) of PCBs

are found in 40 CFR 761.20(e), 2013 edition, incorporated by

reference, and R315-15-18. Prohibition of PCB oil dilution is

described in 40 CFR 279.10 and 40 CFR 761.20(e).


  1.3 PROHIBITIONS

  Except as authorized by the Director, a person may not place, discard, or otherwise dispose of used oil in any of the following manners:

  (a) Surface impoundment and waste piles. Used oil shall not be managed in surface impoundments or waste piles unless the units are subject to regulation under R315-264 or R315-265.

  (b) Use as a dust suppressant, weed suppressant, or for road oiling. The use of used oil as a dust suppressant, weed suppressant, or for road oiling or other similar use is prohibited. Any disposal of used oil on the ground is prohibited under Utah Code Annotated 19-6-706(1)(a)(iii).

  (c) A person may not mix or commingle used oil with the following substances, except as incidental to the normal course of processing, mechanical, or industrial operations:

  (1) Solid waste that is to be disposed of in any solid waste treatment, storage, or disposal facility, except as authorized by the Director; or

  (2) Any hazardous waste so the resulting mixture may not be recycled or used for other beneficial purpose as authorized under R315-15.

  (d) Used oil shall not be disposed in a solid waste treatment, storage, or disposal facility, except for the disposal of hazardous used oil as authorized under R315-261.

  (e) Used oil shall not be disposed in sewers, drainage systems, septic tanks, surface or ground waters, watercourses, or any body of water.

  1.4 BURNING IN PARTICULAR UNITS

  Burning in particular units. Off-specification used oil fuel may be burned for energy recovery only in the devices described in R315-15-6.2(a).

  1.5 DISPOSAL OF DE MINIMIS USED OIL

  (a) R315-15-1.3 does not apply to release of de minimis quantities of used oil identified under Utah Code Annotated 19-6-706(4)(a) except for the requirements of 19-6-706(i) and (ii).

  (b) A person may dispose of an item or substance that contains de minimis amounts of oil in disposal facilities in accordance with Utah Code Annotated 19-6-706 (2) (a) if:

  (1) To the extent that all oil has been reasonably removed from the item or substance; and

  (2) No free flowing oil remains in the item or substance.

  1.6 USED OIL FILTERS

  (a) Disposal of Used Oil Filters. A person may dispose of a nonterne plated used oil filter as a non-hazardous solid waste when that filter is gravity hot-drained by one of the methods described in R315-15-1.6(b) and is not mixed with hazardous waste defined in R315-261.

  (b) "Gravity hot-drained" means drained for not less than 12 hours near operating temperature but above 60 degrees Fahrenheit. A nonterne used oil filter is a container of used oil and is subject to R315-15 until it is gravity hot-drained by one of the following methods:

  (1) puncturing the filter anti-drain back valve or the filter dome end and gravity hot-draining;

  (2) gravity hot-draining and crushing;

  (3) dismantling and gravity hot-draining; or

  (4) any other equivalent gravity hot-draining method authorized by the Director that will remove used oil from the filter at least as effectively as the methods listed in R315-15-1.6(b)(1) through (3).

  1.7 DEFINITIONS

  (a) Definitions of terms used in R315-15 are found in: R315-15-1.7(b) through (h) and R315-260.

  (b) The term "de minimis quantities of used oil" defined in Utah Code Annotated 19-6-706(4)(b), and 19-6-708(3)(a) means small spills, leaks, or drippings from pumps, machinery, pipes, and other similar equipment during normal operations and does not apply to used oil discarded as a result of abnormal operations resulting in substantial leaks, spills, or other releases. Nor does it apply to accumulations of quantities of used oil that pose a potential threat to human health or the environment.

  (c) "Financial responsibility" means the mechanism by which a person who has a financial obligation satisfies that obligation.

  (d) "Used oil" means any oil, refined from crude oil or synthetic oil, that has been used and as a result of that use is contaminated by physical or chemical impurities. Used oil includes engine oil, transmission fluid, compressor oils, metalworking oils, hydraulic oil, brake fluid, oils used as buoyants, lubricating greases, electrical insulating, and dialectic oils.

  (e) "Polychlorinated biphenyl (PCB)" means any chemical substance that is limited to the biphenyl molecule that has been chlorinated to varying degrees or any combination of substances which contains such substance.

  (f) "On-specification used oil" means used oil that does not exceed levels of constituents and properties specified in R315-15-1.2.

  (g) "Off-specification used oil" means used oil that exceeds levels of constituents and properties specified in R315-15-1.2.

  (h) "Parts per million (ppm)" means a weight-per-weight ratio used to describe concentrations. Parts per million (ppm) is the number of units of mass of a contaminant per million units of total mass (e.g., micrograms per gram).

  1.8 LABORATORY ANALYSES

  Laboratory analyses used to satisfy the requirements of R315-15 shall be performed by a laboratory that holds a current Utah Certification for environmental laboratories issued by the Utah Department of Health, Laboratory Improvement under R444-14 Utah Administrative Code. The laboratory shall be certified for the method(s) and analyte(s) applied to generate the environmental data.


R315-15-2. Standards for Used Oil Generators
Latest version.

  2.1 APPLICABILITY

  (a) General. Except as provided in paragraphs (a)(1) through (a)(4) of this section, R315-15-2 applies to all used oil generators. A used oil generator is any person, by site, whose act or process produces used oil or whose act first causes used oil to become subject to regulation.

  (1) Household "do-it-yourselfer" used oil generators. Household "do-it-yourselfer" used oil generators are not subject to regulation under R315-15, except for the prohibitions of R315-15-1.3 and cleanup requirements of R315-15-9.

  (2) Vessels. Vessels at sea or at port are not subject to R315-15-2. For purposes of R315-15-2, used oil produced on vessels from normal shipboard operations is considered to be generated at the time it is transported ashore. The owner or operator of the vessel and the person(s) removing or accepting used oil from the vessel are co-generators of the used oil and are both responsible for managing the used oil in compliance with R315-15-2 once the used oil is transported ashore. The co-generators may decide among themselves which party will fulfill the requirements of R315-15-2.

  (3) Diesel fuel. Mixtures of used oil and diesel fuel mixed by the generator of the used oil for use in the generator's own vehicles are not subject to R315-15 once the used oil and diesel fuel have been mixed. Prior to mixing, the used oil fuel is subject to the requirements of R315-15-2.

  (4) Farmers. Farmers who generate an average of 25 gallons per month or less of used oil from vehicles or machinery used on the farm in a calendar year are not subject to the requirements of R315-15, except for the prohibitions of R315-15-1.3 and cleanup requirements of R315-15-9.

  (b) Other applicable provisions. Used oil generators who conduct the following activities are subject to the requirements of other applicable provisions of R315-15 as indicated in R315-15.2.1(b)(1) through (5):

  (1) Generators who transport used oil, except under the self-transport provisions of R315-15-2.5(a) and (b), shall also comply with R315-15-4.

  (2)(i) Except as provided in R315-15-2.1(b)(2)(ii), generators who process or re-refine used oil must also comply with R315-15-5.

  (ii) Generators who perform the following activities are not processors, provided that the used oil is generated onsite and is not being sent offsite to a burner of on- or off-specification used oil fuel.

  (A) Filtering, cleaning, or otherwise reconditioning used oil before returning it for reuse by the generator;

  (B) Separating used oil from wastewater generated onsite to make the wastewater acceptable for discharge or reuse in accordance with section 402 or section 307(b) of the Clean Water Act or other applicable Federal or state regulations governing the management or discharge of wastewater;

  (C) Using oil mist collectors to remove small droplets of used oil from in-plant air to make plant air suitable for continued recirculation;

  (D) Draining or otherwise removing used oil from materials containing or otherwise contaminated with used oil in order to remove excessive used oil to the extent possible in accordance with R315-15-1.1(c); or

  (E) Filtering, separating or otherwise reconditioning used oil before burning it in a space heater in accordance with R315-15-2.4.

  (3) Generators who burn off-specification used oil for energy recovery, shall also comply with R315-15-6.

  (4) Generators who direct shipments of off-specification used oil from their facility to a used oil burner or first certify that used oil that is to be burned for energy recovery meets the used oil fuel specifications set forth in R315-15-1.2 shall also comply with R315-15-7.

  (5) Generators who dispose of used oil shall also comply with R315-15-8.

  2.2 HAZARDOUS WASTE MIXING

  (a) Mixtures of used oil and hazardous waste shall be managed in accordance with R315-15-1.1(b).

  (b) The rebuttable presumption for used oil found in R315-15-1.1(b)(1)(ii) applies to used oil managed by generators. Under this rebuttable presumption, used oil containing greater than 1,000 ppm total halogens is presumed to be a hazardous waste and thus shall be managed as hazardous waste and not as used oil unless the presumption is rebutted. However, the rebuttable presumption does not apply to certain metalworking oil or fluids containing chlorinated paraffins, if they are processed through a tolling agreement to reclaim the metalworking oils or fluids, and certain used oils removed from refrigeration units described in R315-15-1.1(b)(1)(ii)(B).

  2.3 USED OIL STORAGE

  Used oil generators are subject to all applicable Spill Prevention, Control and Countermeasures, 40 CFR 112, in addition to the requirements of R315-15-2. Used oil generators are also subject to the standards and requirements of R311-200 through R311-209, Underground Storage Tanks, for used oil stored in underground tanks whether or not the used oil exhibits any characteristics of hazardous waste. In addition, used oil generators are subject to the requirements of R315-15-2.

  (a) Storage units. Used oil generators shall not store used oil in units other than tanks, containers, or units subject to regulation under R315-264 and R315-265.

  (b) Condition of units. Containers and aboveground tanks used to store used oil at generator facilities shall be:

  (1) In good condition, with no severe rusting, apparent structural defects or deterioration; and

  (2) Not leaking.

  (3) Tanks and containers for storage of used oil must be closed during storage except when adding or removing used oil.

  (4) Tanks and containers storage areas shall be managed to prevent releases of used oil to the environment.

  (c) Labels.

  (1) Containers and aboveground tanks used to store used oil at generator facilities shall be labeled or marked clearly with the words "Used Oil".

  (2) Fill pipes used to transfer used oil into underground storage tanks at generator facilities shall be labeled or marked clearly with the words "Used Oil."

  (d) Response to releases. Upon detection of a release of used oil to the environment not subject to the requirements of Section R311-202-1, which incorporates by reference 40 CFR 280, Subpart F, a generator shall comply with Section R315-15-9.

  2.4 ON-SITE BURNING

  On-site burners shall comply with R315-15-6 and, if applicable, shall obtain an Air Quality permit.

  (a) Generators may burn used oil in used oil-fired space heaters without a used oil permit provided that:

  (1) The heater burns only used oil that the owner or operator generates;

  (2) The heater is designed to have a maximum capacity of not more than 0.5 million Btu per hour;

  (3) The combustion gases from the heater are vented to the outside ambient air;

  (4) The generator has knowledge that the used oil has not been mixed with hazardous waste; and

  (5) The used oil is being legitimately burned to utilize its energy content.

  (b) Used Oil Collection Center(UOCC). If it is registered as a Used Oil Collection Center as authorized in R315-15-3, the UOCC may burn used oil in used oil fired space heaters without a used oil permit under the provision described in R315-15-2.4(a) provided that the used oil is received from household do-it-yourselfer generators or farmers described in R315-15-2.1(a)(4) or the used oil is received from other generators and has been certified to meet the used oil fuel specifications of R315-15-1.2 by a registered used oil marketer in accordance with R315-15-7.

  2.5 OFF-SITE SHIPMENTS

  Except as provided in R315-15-2.5(a) through (c), a generator shall ensure that its used oil is transported only by a transporter who has obtained a Utah used oil transporter permit and has a current used oil handler certificate issued by the Director and an EPA identification number.

  (a) Self-transportation of small amounts to approved collection centers. A generators may transport, without an EPA identification number, a used oil transporter permit, or a current used oil handler certificate, used oil that is generated at the generator's site and used oil collected from household do-it-yourselfers to a used oil collection center provided that:

  (1) The generator transports the used oil in a vehicle owned by the generator or owned by an employee of the generator;

  (2) The generator transports no more than 55 gallons of used oil at any time; and

  (3) The generator transports the used oil to a used oil collection center that is registered or permitted to manage used oil.

  (b) Self-transportation of small amounts to aggregation points owned by the generator. A generator may transport, without an EPA identification number, a used oil transporter permit, or used oil handler certificate, used oil that is generated at the generator's site to an aggregation point provided that:

  (1) The generator transports the used oil in a vehicle owned by the generator or owned by an employee of the generator;

  (2) The generator transports no more than 55 gallons of used oil at any time; and

  (3) The generator transports the used oil to an aggregation point that is owned, operated, or both by the same generator.

  (c) Tolling arrangements. Used oil generators may arrange for used oil to be transported by a transporter without an EPA identification number, a used oil transporter permit, or a current used oil handler certificate if the used oil is reclaimed under a contractual agreement under which reclaimed oil is returned by the processor/re-refiner to the generator for use as a lubricant, cutting oil, or coolant. The contract, known as a "tolling arrangement," shall indicate:

  (1) The type of used oil and the frequency of shipments;

  (2) That the vehicle used to transport the used oil to the processing/re-refining facility and to deliver recycled used oil back to the generator is owned and operated by the used oil processor/re-refiner; and

  (3) That reclaimed oil will be returned to the generator.


R315-15-3. Standards for Used Oil Collection Centers and Aggregation Points
Latest version.

  3.1 DO-IT-YOURSELFER USED OIL COLLECTION CENTERS TYPES A and B

  (a) Applicability. R315-15-3.1 applies to owners or operators of Type A and B used oil collection centers:

  (1) Type A used oil collection center. Type A and B is any site or facility that accepts/aggregates and stores used oil collected only from household do-it-yourselfers (DIYers) in quantities not exceeding five gallons per visit.

  (2) Type B used oil collection center. Type B used oil collection center is any site or facility that accepts/aggregates and stores used oil collected from farmers as required by R315-15-2.1(a)(4) in quantities not exceeding 55 gallons per visit from farmers and not exceeding five gallons per visit from household do-it-yourselfers.

  (b) Type A or B used oil collection center requirements. Owners or operators of Type A or B used oil collection centers shall:

  (1) Comply with the generator standards in R315-15-2.

  (2) Be registered with the Division of Waste Management and Radiation Control to manage used oil as a used oil collection center as required by R315-15-13.1; and

  (3) Keep records of used oil collected by the collection center. This does not include used oil generated on site from maintenance and servicing operations. These records shall be kept for a minimum of three years and shall contain the following information:

  (i) Name and address of generator or if unavailable, a written description of how the used oil was received;

  (ii) Quantity of used oil received;

  (iii) Date the used oil is received; and

  (iv) Volume of used oil picked up by a permitted transporter and the transporter's name and EPA identification number.

  (4) A Type A or B used oil collection center shall not accept used oil from generators other than those specified in R315-15-3.1(1) and (2).

  (c) Reimbursements. Type A or B used oil collection centers are classified as DIYer used oil collection centers and may be reimbursed as described in R315-15-14.

  3.2 USED OIL COLLECTION CENTERS - TYPES C AND D

  (a) Applicability. R315-15-3.2 applies to owners or operators of Type C and D used oil collection centers.

  (1) Type C used oil collection center is any site or facility that accepts/aggregates and stores used oil collected from used oil generators regulated under R315-15-2 who bring used oil to the collection center in shipments of no more than 55 gallons under the provisions of R315-15-2.5(a). Type C used oil collection centers may also accept used oil from household do-it-yourselfers and farmers described in R315-15-2.1(a)(4).

  (2) A Type D used oil collection center is any site or facility that only accepts/aggregates and stores used oil collected from used oil generators regulated under R315-15-2 who bring used oil to the collection center in shipments of no more than 55 gallons under the provisions of R315-15-2.5(a). Type D used oil collection centers do not qualify for reimbursement.

  (b) Used oil collection center Type C and D requirements. Owners or operators of Types C and D used oil collection centers shall:

  (1) Comply with the generator standards in R315-15-2;

  (2) Be registered with the Division of Waste Management and Radiation Control to manage used oil; and

  (3) Keep records of used oil received from off-site sources and transported from the collection center. This does not include used oil generated onsite from maintenance and servicing operations. These records shall be kept for a minimum of three years and shall contain the following information:

  (i) Name and address of generator or, if unavailable, a written description of how the used oil was received;

  (ii) Quantity of used oil received;

  (iii) Date the used oil is received; and

  (iv) Volumes of used oil collected by a permitted transporter and the transporter's name and federal EPA identification number.

  (c) Reimbursements. Type C used oil collection centers may be reimbursed as described in R315-15-14 for household do-it-yourselfer and used oil generated by farmers as defined in R315-15-3.1. Other generator used oil does not meet the reimbursement criteria as do-it-yourselfer used oil and does not qualify for reimbursement.

  3.3 USED OIL AGGREGATION POINTS OWNED BY THE GENERATOR

  (a) Applicability. R315-15-3.3 applies to owners or operators of all used oil aggregation points. A used oil aggregation point is any site or facility that accepts, aggregates, or stores used oil collected only from other used oil generation sites owned or operated by the owner or operator of the aggregation point, from which used oil is transported to the aggregation point in shipments of 55 gallons or less under the provisions of R315-15-2.5(b). Used oil aggregation points may also accept used oil from household do-it-yourselfers as long as they register as do-it-yourselfer collection centers, as described in R315-15-13.1, and comply with do-it-yourselfer collection center standards in R315-15-3.1. Used oil aggregation points that accept used oil from other generators shall register as collection centers, as described in R315-15-13.2, and comply with collection center standards in R315-15-3.2.

  (b) Used oil aggregation point requirements. Owners or operators of all used oil aggregation points shall comply with the generator standards in R315-15-2.


R315-15-4. Standards for Used Oil Transporter and Transfer Facilities
Latest version.

  4.1 APPLICABILITY

  (a) General. R315-15-4 applies to all used oil transporters, except as provided in R315-15-4.1(a)(1) through (4). Persons who transport used oil, persons who collect used oil from more than one generator and transport the collected used oil, and owners and operators of used oil transfer facilities are used oil transporters. Except as provided by R315-15-13.4(f), used oil transporters or operators of used oil transfer facilities shall obtain a permit from the Director prior to accepting any used oil for transportation or transfer. The application for a permit shall include the information required by R315-15-13.4. Used oil transporters and operators of used oil transfer facilities shall obtain and maintain a used oil handler certificate in accordance with R315-15-13.8.

  (1) R315-15-4 does not apply to on-site transportation.

  (2) R315-15-4 does not apply to generators who transport shipments of used oil totaling 55 gallons or less from the generator to a used oil collection center as specified in Subsection R315-15-2.5(a).

  (3) R315-15-4 does not apply to generators who transport shipments of used oil totaling 55 gallons or less from the generator to a used oil aggregation point owned or operated by the same generator as specified in R315-15-2.5(b).

  (4) R315-15-4 does not apply to transportation of used oil from household do-it-yourselfers to a regulated used oil generator, collection center, aggregation point, processor/re-refiner, or burner subject to the requirements of R315-15. Except as provided in R315-15-4.1(a)(1) through (a)(3), R315-15-4 does, apply to transportation of collected household do-it-yourselfer used oil from regulated used oil generators, collection centers, aggregation points, or other facilities where household do-it-yourselfer used oil is collected.

  (b) Imports and exports. Transporters are subject to the requirements of R315-15-4 from the time the used oil enters and until the time it exits Utah.

  (c) Vehicles used to transport hazardous waste. Unless vehicles previously used to transport hazardous waste are emptied as described in R315-261-7 prior to transporting used oil, the used oil is considered to have been mixed with the hazardous waste and shall be managed as hazardous waste unless, under the provisions of R315-15-1.1(b), the hazardous waste/used oil mixture is determined not to be hazardous waste.

  (d) Vehicles used to transport PCB-contaminated material. Unless vehicles previously used to transport PCB-contaminated material are decontaminated as described in 40 CFR 761 Subpart S, (2013 edition, incorporated by reference), prior to transporting used oil, the used oil is considered to have been mixed with PCB-contaminated material and shall be managed as PCB-contaminated material in accordance with R315-15-18 and 40 CFR 761.

  (e) Tanks, containers, and piping that contained PCB-contaminated material. Unless tanks, containers, and piping that previously contained PCB-contaminated material are decontaminated as described in 40 CFR 761 Subpart S prior to transferring used oil, the used oil is considered to have been mixed with PCB-contaminated material in accordance with R315-15-18 and 40 CFR 761 Subpart S.

  (f) Other applicable provisions. Used oil transporters who conduct the following activities are also subject to other applicable provisions of R315-15 as indicated in R315-15-4.1 (f)(1) through (5):

  (1) Transporters who generate used oil shall also comply with R315-15-2;

  (2) Transporters who process or re-refine used oil, except as provided in R315-15-4.2, shall also comply with R315-15-5;

  (3) Transporters who burn off-specification used oil for energy recovery shall also comply with R315-15-6;

  (4) Transporters who direct shipments of off-specification used oil from their facility to a used oil burner or first claim that used oil that is to be burned for energy recovery meets the used oil fuel specifications set forth in R315-15-1.2 shall also comply with R315-15-7; and

  (5) Transporters who dispose of used oil shall also comply with R315-15-8.

  4.2 RESTRICTIONS ON TRANSPORTERS WHO ARE NOT ALSO PROCESSORS OR RE-REFINERS

  (a) Used oil transporters may consolidate or aggregate loads of used oil for purposes of transportation. However, except as provided in R315-15-4.2(b), used oil transporters may not process used oil unless they also comply with the requirements for processors/re-refiners in R315-15-5.

  (b) Transporters may conduct incidental processing operations that occur in the normal course of used oil transportation, e.g., settling and water separation, but that are not designed to produce, or make more amenable for production of, used oil derived products unless they also comply with the processor/re-refiner requirements in R315-15-5.

  (c) Transporters of used oil that is removed from oil-bearing electrical transformers and turbines and filtered by the transporter or at a transfer facility prior to being returned to its original use are not subject to the processor/re-refiner requirements in R315-15-5.

  4.3 NOTIFICATION

  (a) Identification numbers. Used oil transporters who have not previously complied with the notification requirements of RCRA section 3010 shall comply with these requirements and obtain an EPA identification number.

  (b) Mechanics of notification. A used oil transporter who has not received an EPA identification number may obtain one by notifying the Director of his used oil activity by submitting either:

  (1) A completed EPA Form 8700-12 or

  (2) A letter to the Division requesting an EPA identification number. The letter shall include the following information:

  (i) Transporter company name;

  (ii) Owner of the transporter company;

  (iii) Mailing address for the transporter;

  (iv) Name and telephone number for the transporter point of contact;

  (v) Type of transport activity, i.e., transport only, transport and transfer facility, transfer facility only;

  (vi) Location of all transfer facilities at which used oil is stored; and

  (vii) Name and telephone number for a contact at each transfer facility.

  4.4 USED OIL TRANSPORTATION

  (a) Deliveries. A used oil transporter shall deliver all used oil received to:

  (1) Another used oil transporter, provided that the transporter has obtained an EPA identification number transporter, permit number, and current used oil handler certificate issued by the Director;

  (2) A used oil processing/re-refining facility that has obtained an EPA identification number, processing/refining permit, and current used oil handler certificate issued by the Director;

  (3) An off-specification used oil burner facility that has obtained an EPA identification number, off-specification used oil burner permit, and current used oil handler certificate issued by the Director;

  (4) A used oil transfer facility that has obtained an EPA identification number, transfer facility permit, and current used oil handler certificate issued by the Director; or

  (5) An on-specification used oil burner facility.

  (b) DOT Requirements. Used oil transporters shall comply with all applicable requirements under the U.S. Department of Transportation regulations in 49 CFR 171 through 180. Persons transporting used oil that meets the definition of a hazardous material in 49 CFR 171.8 shall comply with all applicable regulations in 49 CFR 171 through 180.

  (c) Used oil discharges. In the event of a used oil discharge, a transporter shall comply with R315-15-9.

  (d) The words "Used Oil" shall be clearly visible, in letters at least two inches high, on all vehicles transporting bulk used oil.

  4.5 REBUTTABLE PRESUMPTION FOR USED OIL

  (a) To ensure that used oil is not a hazardous waste under the rebuttable presumption of R315-15-1.1(b)(1)(ii), the used oil transporter shall determine whether the total halogen content of used oil being transported or stored at a transfer facility is below 1,000 ppm.

  (b) The transporter shall make this determination by:

  (1) Testing the used oil; or

  (2) Applying and documenting generator knowledge of the halogen content of the used oil in light of the materials or processes used.

  (c) If the used oil contains greater than or equal to 1,000 ppm total halogens, it is presumed to be a hazardous waste because it has been mixed with halogenated hazardous waste listed in R315-261-30 through 33 and 35. The owner or operator may rebut the presumption by demonstrating that the used oil does not contain hazardous waste, for example, by using an analytical method from SW-846, Edition III, update IV to show that the used oil does not contain significant concentrations of halogenated hazardous constituents listed in R315-261 Appendix VIII.

  (1) The rebuttable presumption does not apply to metalworking oils/fluids containing chlorinated paraffins, if they are processed, through a tolling arrangement as described in R315-15-2.5(c), to reclaim metalworking oils/fluids. The presumption does apply to metalworking oils/fluids if such oils/fluids are recycled in any other manner, or disposed.

  (2) The rebuttable presumption does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units if the CFCs are destined for reclamation. The rebuttable presumption does apply to used oils contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units.

  (d) Record retention. Records of analyses conducted or information used to comply with R315-15-4.5(a), (b), and (c) shall be maintained by the transporter for at least three years.

  4.6 USED OIL STORAGE AT TRANSFER FACILITIES

  Used oil transporters are subject to all applicable Spill Prevention, Control and Countermeasures, in accordance with 40 CFR 112, in addition to the requirements of R315-15-4. Used oil transporters are also subject to the standards of R311, which incorporates by reference 40 CFR 280, for used oil stored in underground tanks whether or not the used oil exhibits any characteristics of hazardous waste, in addition to the requirements of R315-15-4.

  (a) Applicability. R315-15-4 applies to used oil transfer facilities. Used oil transfer facilities are transportation-related facilities including loading docks, parking areas, storage areas, and other areas where shipments of used oil are held for more than 24 hours during the normal course of transportation and not longer than 35 days. Transfer facilities that store used oil for more than 35 days are subject to the processor/re-refiner requirements found in R315-15-5.

  (b) Storage units. Owners or operators of used oil transfer facilities may not store used oil in units other than tanks, containers, or units subject to regulation under R315-264 or R315-265.

  (c) Condition of units. Containers and aboveground tanks and tank systems, including their associated pipes and valves, used to store used oil at transfer facilities shall be:

  (1) In good condition, with no severe rusting, apparent structural defects, or deterioration; and

  (2) Not leaking.

  (3) Tanks and containers for storage of used oil must be closed during storage except when adding or removing used oil.

  (4) Tanks and container storage areas shall have a containment system that is designed and operated in accordance with R315-264-170 through 178.

  (d) Secondary containment. Containers and aboveground tanks used to store used oil at transfer facilities, including their pipe connections and valves, shall be equipped with a secondary containment system.

  (1) The secondary containment system shall consist of:

  (i) Dikes, berms, or retaining walls; and

  (ii) A floor. The floor shall cover the entire area within the dikes, berms, or retaining walls except areas where existing portions of existing aboveground tanks meet the ground.

  (iii) An equivalent secondary containment system approved by the Director.

  (2) The entire containment system, including walls and floors, shall be sufficiently impervious to used oil to prevent any used oil released into the containment system from migrating out of the system to the soil, groundwater, or surface water.

  (3) The secondary system shall be of sufficient extent to prevent any used oil releases from tanks and containers in R315-15-4.6(b), from migrating out of the system to the soil, groundwater, or surface water.

  (4) Water, used oil, or other liquids shall be removed from secondary containment, including sumps, within 24 hours of discovery.

  (5) Used oil shall not be stored or allowed to accumulate in sumps and similar water containment structures at the facility. Any used oil in such sumps beyond a surface sheen shall be removed within 24 hours of discovery.

  (6) Transporters loading to or from rail tanker cars shall also comply with secondary containment requirements of R315-15-4.10.

  (e) Labels.

  (1) Containers and aboveground tanks used to store used oil at transfer facilities shall be labeled or marked clearly with the words "Used Oil."

  (2) Fill pipes used to transfer used oil into underground storage tanks at transfer facilities shall be labeled or marked clearly with the words "Used Oil."

  (f) Response to releases. Upon detection of a release of used oil to the environment not subject to the requirements of R311-202-1, which incorporates by reference 40 CFR 280, Subpart F, the owner/operator of a transfer facility shall comply with R315-15-9.

  4.7 TRACKING

  (a) Acceptance. Used oil transporters and transfer facilities shall keep a written record of each used oil shipment accepted for transport. These records shall take the form of a log, invoice, manifest, bill of lading, or other shipping documents. Written records for each shipment shall include:

  (1) The name and address of the generator, transporter, transfer facility, burner, or processor/re-refiner who provided the used oil for transport;

  (2) The EPA identification number, if applicable, of the generator, transporter, or processor/re-refiner who provided the used oil for transport;

  (3) Documentation demonstrating the transporter has met the halogen determination requirements of R315-15-4.5 and, where applicable, the PCB testing requirements of R315-15-18;

  (4) The quantity of used oil accepted;

  (5) The date of acceptance; and

  (6)(i) Except as provided in R315-15-4.7(a)(6)(ii), the signature, dated upon receipt of the used oil, of a representative of the generator, transporter, transfer facility, burner, or processor/re-refiner who provided the used oil for transport.

  (ii) Intermediate rail transporters are not required to sign the record of acceptance.

  (b) Deliveries. Used oil transporters and transfer facilities shall keep a written record of each shipment of used oil that is delivered to another used oil transporter, a transfer facility, burner, processor/re-refiner, or disposal facility. Records of each delivery shall include:

  (1) The name and address of the receiving facility or transporter;

  (2) The EPA identification number of the receiving facility or transporter;

  (3) The quantity of used oil delivered;

  (4) The date of delivery; and

  (5)(i) Except as provided in R315-15-4.7(a)(6)(ii), the signature, dated upon receipt of the used oil, of a representative of the receiving facility or transporter.

  (ii) Intermediate rail transporters are not required to sign the record of delivery.

  (c) Exports of used oil. Used oil transporters shall maintain the records described in R315-15-4.7(b)(1) through (b)(4) for each shipment of used oil exported outside of Utah.

  (d) Record retention. The records described in R315-15-4.7(a), (b), and (c) shall be maintained for at least three years at a specified facility approved by the Director.

  (e) Reporting. Used oil transporter and transfer facilities shall report annually by March 1 to the Director. The report shall be consistent with the requirements of R315-15-13.4(d).

  4.8 MANAGEMENT OF RESIDUES

  Transporters who generate residues from the storage or transport of used oil shall manage the residues as specified in R315-15-1.1(e).

  4.9 ACCEPTANCE OF OFF-SITE USED OIL

  Used oil transporters and transfer facilities accepting used oil from off-site shall ensure that the transporters delivering the used oil have obtained a current used oil transporter permit and an EPA identification number.

  4.10 TRANSFER OF USED OIL TO OR FROM RAIL CARS

  (a) Spill prevention. Facilities or transporters loading or unloading used oil from rail cars shall:

  (1) Use spill pans beneath rail cars being loaded or unloaded with used oil. These spill pans shall be placed inside and outside of the track below the rail car loading port in such a way as to capture releases that might occur during the loading and unloading operations;

  (2) Securely park used oil transportation trucks on a loading pad during the loading and unloading of used oil between those trucks and the rail tanker car. The loading pad shall be constructed of asphalt or concrete, or an equivalent system approved by the Director, and shall be sloped or bermed in such a way as to contain used oil spills;

  (3) Be loaded and unloaded through a valve or port located on top of the rail car unless otherwise approved by the Director; and

  (4) Transporter personnel shall actively monitor the transfer during the entire loading and unloading process.

  (b) Storage at rail loading and unloading facilities. If, during the normal course of transportation, used oil remains at the loading and unloading facility for more than 24 hours but less than 35 days, the facility is subject to regulation as a used oil transfer facility as defined in R315-15-4.6 and is required to apply for a permit as a used oil transfer facility as defined in R315-15-13.4. A transfer facility that stores used oil for more than 35 days is subject to the processor/re-refiner requirements as defined in R315-15-5.


R315-15-5. Standards for Used Oil Processors and Re-Refiners
Latest version.

  5.1 APPLICABILITY

  (a) The requirements of R315-15-5 apply to owners and operators of facilities that process used oil. Processing means chemical or physical operations designed to produce from used oil, or to make used oil more amenable for production of, fuel oils, lubricants, or other used oil-derived products. Processing includes: blending used oil with virgin petroleum products, blending used oils to meet the fuel specification, filtration, simple distillation, chemical or physical separation and re-refining. The requirements of R315-15-5 do not apply to:

  (1) Transporters that conduct incidental processing operations that occur during the normal course of transportation as provided in R315-15-4.2; or

  (2) Burners that conduct incidental processing operations that occur during the normal course of used oil management prior to burning as provided in R315-15-6.2(b).

  (b) Other applicable provisions. Used oil processors/re-refiners who conduct the following activities are also subject to the requirements of other applicable provisions of R315-15 as indicated in R315-15-5.1(b)(1) through (b)(7).

  (1) Processors/re-refiners who generate used oil shall also comply with R315-15-2.

  (2) Processors/re-refiners who transport used oil shall also comply with R315-15-4.

  (3) Processor/re-refiners who burn off-specification used oil for energy recovery shall also comply with R315-15-6 except where:

  (i) The used oil is only burned in an on-site space heater that meets the requirements of R315-15-2.4; or

  (ii) The used oil is only burned for purposes of processing used oil, which is considered burning incidentally to used oil processing.

  (4) Processors/re-refiners who direct shipments of off-specification used oil from their facility to a used oil burner or first claim that used oil that is to be burned for energy recovery meets the used oil fuel specifications set forth in R315-15-1.2 shall also comply with R315-15-7.

  (5) Processors/re-refiners who dispose of used oil shall also comply with R315-15-8.

  (6) Tanks, containers, and piping that contained hazardous waste. Unless tanks, containers, and piping that previously contained hazardous waste are emptied as described in R315-261-7 prior to storing or transferring used oil, the used oil is considered to have been mixed with the hazardous waste and shall be managed as hazardous waste unless, under the provisions of R315-15-1.1(b), the hazardous waste and used oil mixture is determined not to be hazardous waste.

  (7) Tanks, containers, and piping that previously contained PCB-contaminated material. Unless tanks, containers, and piping that previously contained PCB-contaminated material are decontaminated as described in 40 CFR 761 Subpart S prior to storing or transferring of used oil, the used oil is considered to have been mixed with the PCB-contaminated material and shall be managed in accordance with R315-15-18 and 40 CFR 761 Subpart S, as applicable.

  (c) Processors/re-refiners shall obtain a permit from the Director prior to processing or re-refining used oil. An application for a permit shall contain the information required by R315-15-13.5.

  5.2 NOTIFICATION

  (a) Identification numbers. Used oil processors/re-refiners who have not previously complied with the notification requirements of RCRA section 3010 shall comply with these requirements and obtain an EPA identification number.

  (b) Mechanics of notification. A used oil processor or re-refiner who has not received an EPA identification number may obtain one by notifying the Director of their used oil activity by submitting either:

  (1) A completed EPA Form 8700-12; or

  (2) A letter to the Division requesting an EPA identification number. The letter shall include the following information:

  (i) Processor or re-refiner company name;

  (ii) Owner of the processor or re-refiner company;

  (iii) Mailing address for the processor or re-refiner;

  (iv) Name and telephone number for the processor or re-refiner point of contact;

  (v) Type of used oil activity, i.e., process only, process and re-refine;

  (vi) Location of the processor or re-refiner facility.

  5.3 GENERAL FACILITY STANDARDS

  (a) Preparedness and prevention. Owners and operators of used oil processor/re-refiner facilities shall comply with the following requirements:

  (1) Maintenance and operation of facility. Facilities shall be maintained and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or non-sudden release of used oil to air, soil, surface water, or groundwater that could threaten human health or the environment.

  (2) Required equipment. All facilities shall be equipped with the following:

  (i) An internal communications or alarm system capable of providing immediate emergency instruction, voice and signal, to facility personnel;

  (ii) A device, such as a telephone, immediately available at the scene of operations, or a hand-held two-way radio, capable of summoning emergency assistance from local police departments, fire departments, or State or local emergency response teams;

  (iii) Portable fire extinguishers, fire control equipment, including special extinguishing equipment, such as that using foam, inert gas, or dry chemicals, spill control equipment, and decontamination equipment; and

  (iv) Water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems.

  (3) Testing and maintenance of equipment. All facility communications or alarm systems, fire protection equipment, spill control equipment, and decontamination equipment, where required, shall be tested and maintained as necessary to assure its proper operation in time of emergency. Records of such testing and maintenance shall be kept for three years.

  (4) Access to communications or alarm system.

  (i) Whenever used oil is being poured, mixed, spread, or otherwise handled, all personnel involved in the operation shall have immediate access to an internal alarm or emergency communication device, either directly or through visual or voice contact with another employee, unless such a device is not required in R315-15-5.3(a)(2).

  (ii) If there is ever just one employee on the premises while the facility is operating, the employee shall have immediate access to a device, such as a telephone, immediately available at the scene of operation, or a hand-held two-way radio, capable of summoning external emergency assistance, unless such a device is not required in R315-15-5.3(a)(2).

  (5) Required aisle space. The owner or operator shall maintain aisle space to allow the unobstructed movement of personnel, fire protection equipment, spill control equipment, and decontamination equipment to any area of facility operation in an emergency, unless aisle space is not needed for any of these purposes.

  (6) Arrangements with local authorities.

  (i) The owner or operator shall attempt to make the following arrangements, as appropriate for the type of used oil handled at the facility and the potential need for the services of these organizations:

  (A) Arrangements to familiarize police, fire departments, and emergency response teams with the layout of the facility, properties of used oil handled at the facility and associated hazards, places where facility personnel would normally be working, entrances to roads inside the facility, and possible evacuation routes;

  (B) Where more than one police and fire department might respond to an emergency, agreements designating primary emergency authority to a specific police and a specific fire department, and agreements with any others to provide support to the primary emergency authority;

  (C) Agreements with State emergency response teams, emergency response contractors, and equipment suppliers; and

  (D) Arrangements to familiarize local hospitals with the properties of used oil handled at the facility and the types of injuries or illnesses that could result from fires, explosions, or releases at the facility.

  (ii) Where State or local authorities decline to enter into such arrangements, the owner or operator shall document the refusal in the facility's operating record.

  (b) Contingency plan and emergency procedures. Owners and operators of used oil processor and re-refiner facilities shall comply with the following requirements:

  (1) Purpose and implementation of contingency plan.

  (i) Each owner or operator shall have a contingency plan for the facility. The contingency plan shall be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of used oil to air, soil, groundwater, or surface water.

  (ii) The provisions of the plan shall be carried out immediately whenever there is a fire, explosion, or release of used oil that could threaten human health or the environment.

  (2) Content of contingency plan.

  (i) The contingency plan shall describe the actions facility personnel shall take to comply with R315-15-5.3(b)(1) and (6) in response to fires, explosions, or any unplanned sudden or non-sudden release of used oil to air, soil, groundwater, or surface water at the facility.

  (ii) If the owner or operator has already prepared a Spill Prevention, Control, and Countermeasures (SPCC) Plan in accordance with 40 CFR 112 or some other emergency or contingency plan, the owner or operator need only amend that plan to incorporate used oil management provisions necessary to comply with the requirements of R315-15.

  (iii) The plan shall describe arrangements agreed to by local police departments, fire departments, hospitals, contractors, and State and local emergency response teams to coordinate emergency services, in accordance with R315-15-5.3(a)(6).

  (iv) The plan shall list names, addresses, and phone numbers, of all persons qualified to act as 24-hour emergency coordinator. This list shall be kept up to date. Where more than one person is listed, one shall be named as primary emergency coordinator and others shall be listed in the order in which they will assume responsibility as alternates. See also R315-15-5.3(b)(5).

  (v) The plan shall include a list of all emergency equipment at the facility, such as fire extinguishing systems, spill control equipment, communications and alarm systems, internal and external, and decontamination equipment, where this equipment is required. This list shall be kept up to date. In addition, the plan shall include the location and a physical description of each item on the list, and a brief outline of its capabilities.

  (vi) The plan shall include an evacuation plan for facility personnel where there is a possibility that evacuation could be necessary. This plan shall describe signal(s) to be used to begin evacuation, evacuation routes, and alternate evacuation routes, in cases where the primary routes could be blocked by releases of used oil or fires.

  (3) Copies of contingency plan. A copy of the contingency plan and all revisions to the plan shall be:

  (i) Maintained at the facility; and

  (ii) Submitted to all local police departments, fire departments, hospitals, and State and local emergency response teams that may be called upon to provide emergency services.

  (4) Amendment of contingency plan. The contingency plan shall be reviewed, and immediately amended, if necessary, whenever:

  (i) Applicable regulations are revised;

  (ii) The plan fails in an emergency;

  (iii) The facility changes its design, construction, operation, maintenance, or other circumstances in a way that materially increases the potential for fires, explosions, or releases of used oil, or changes the response necessary in an emergency;

  (iv) The list of emergency coordinators changes; or

  (v) The list of emergency equipment changes.

  (5) Emergency coordinator. At all times, there shall be at least one employee either on the facility premises or on call, i.e., available to respond to an emergency by reaching the facility within a short period of time, with the responsibility for coordinating all emergency response measures. This emergency coordinator shall be thoroughly familiar with all aspects of the facility's contingency plan, all operations and activities at the facility, the location and characteristic of used oil handled, the location of all records within the facility, and facility layout. In addition, this person shall have the authority to commit the resources needed to carry out the contingency plan.

  (6) Emergency procedures.

  (i) Whenever there is an imminent or actual emergency situation, the emergency coordinator, or the designee when the emergency coordinator is on call, shall immediately:

  (A) Activate internal facility alarms or communication systems, where applicable, to notify all facility personnel; and

  (B) Notify appropriate State or local agencies with designated response roles if their help is needed.

  (ii) Whenever there is a release, fire, or explosion, the emergency coordinator shall immediately identify the character, exact source, amount, and areal extent of any released materials. The emergency coordinator may do this by observation or review of facility records of manifests and, if necessary, by chemical analysis.

  (iii) Concurrently, the emergency coordinator shall assess possible hazards to human health and to the environment that may result from the release, fire, or explosion. This assessment shall consider both direct and indirect effects of the release, fire, or explosion, e.g., the effects of any toxic, irritating, or asphyxiating gases that are generated, or the effects of any hazardous surface water run-offs from water or chemical agents used to control fire and heat-induced explosions.

  (iv) If the emergency coordinator determines that the facility has had a release, fire, or explosion that could threaten human health, or the environment, outside the facility, the coordinator shall report the findings as follows:

  (A) If the emergency coordinator assessment indicates that evacuation of local areas may be advisable, he shall immediately notify appropriate local authorities. The coordinator shall be available to help appropriate officials decide whether local areas should be evacuated; and

  (B) The emergency coordinator shall implement the actions as required in Section R315-15-9.

  (v) During an emergency, the emergency coordinator shall take all reasonable measures necessary to ensure that fires, explosions, and releases do not occur, recur, or spread to other used oil or hazardous waste at the facility. These measures shall include, where applicable, stopping processes and operation, collecting and containing released used oil, and removing or isolating containers.

  (vi) If the facility stops operation in response to a fire, explosion, or release, the emergency coordinator shall monitor for leaks, pressure buildup, gas generation, or ruptures in valves, pipes, or other equipment, wherever this is appropriate.

  (vii) Immediately after an emergency, the emergency coordinator shall provide for recycling, storing, or disposing of recovered used oil, contaminated soil or surface water, or any other material that results from a release, fire, or explosion at the facility.

  (viii) The emergency coordinator shall ensure that, in the affected area(s) of the facility:

  (A) No waste or used oil that may be incompatible with the released material is recycled, treated, stored, or disposed of until cleanup procedures are completed; and

  (B) All emergency equipment listed in the contingency plan is cleaned and fit for its intended use before operations are resumed.

  (C) The owner or operator shall notify the Director, and appropriate local authorities that the facility is in compliance with R315-15-5.3(b)(6)(viii)(A) and (B) before operations are resumed in the affected area(s) of the facility.

  (ix) The owner or operator shall note in the operating record the time, date, and details of any incident that requires implementing the contingency plan. Within 15 days after the incident, the owner or operator shall submit a written report on the incident to the Director. The report shall include:

  (A) Name, address, and telephone number of the owner or operator;

  (B) Name, address, and telephone number of the facility;

  (C) Date, time, and type of incident, e.g., fire, explosion;

  (D) Name and quantity of material(s) involved;

  (E) The extent of injuries, if any;

  (F) An assessment of actual or potential hazards to human health or the environment, where this is applicable; and

  (G) Estimated quantity and disposition of recovered material that resulted from the incident.

  5.4 REBUTTABLE PRESUMPTION FOR USED OIL

  (a) To ensure that used oil managed at a processing/re-refining facility is not hazardous waste under the rebuttable presumption of R315-15-1.1(b)(1)(ii), the owner or operator of a used oil processing/re-refining facility shall determine whether the total halogen content of used oil managed at the facility is above or below 1,000 ppm.

  (b) The owner or operator shall make this determination by:

  (1) Testing the used oil; or

  (2) Applying and documenting generator knowledge of the halogen content of the used oil in light of the materials and processes used.

  (c) If the used oil contains greater than or equal to 1,000 ppm total halogens, it is presumed to be a hazardous waste because it has been mixed with halogenated hazardous waste listed in R315-261-30 through 33 and 35. The owner or operator may rebut the presumption by demonstrating that the used oil does not contain hazardous waste, for example, by using an analytical method from EPA SW-846, Edition III, Update IV to show that the used oil does not contain significant concentrations of halogenated hazardous constituents listed in R315-261 Appendix VIII.

  (1) The rebuttable presumption does not apply to metalworking oils/fluids containing chlorinated paraffins, if they are processed, through a tolling agreement, to reclaim metalworking oils/fluids. The presumption does apply to metalworking oils/fluids if such oils/fluids are recycled in any other manner, or disposed.

  (2) The rebuttable presumption does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units where the CFCs are destined for reclamation. The rebuttable presumption does apply to used oils contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units.

  5.5 USED OIL MANAGEMENT

  Used oil processor/re-refiners are subject to all applicable Spill Prevention, Control and Countermeasures, found in 40 CFR 112, in addition to the requirements of R315-15-5. Used oil processors/re-refiners are also subject to the standards and requirements found in R311-200 through R311-209, Underground Storage Tanks, for used oil stored in underground tanks whether or not the used oil exhibits any characteristics of hazardous waste, in addition to the requirements of R315-15-5.

  (a) Management units. Used oil processors/re-refiners may not store used oil in units other than tanks, containers, or units subject to regulation under R315-264 or R315-265.

  (b) Condition of units. Containers and aboveground tanks including their associated pipes and valves used to store or process used oil at processing and re-refining facilities shall be:

  (1) In good condition, with no severe rusting, apparent structural defects, or deterioration;

  (2) Not leaking; and

  (3) Closed during storage except when used oil is being added or removed.

  (c) Secondary containment. Containers and aboveground tanks used to store or process used oil at processing and re-refining facilities including their pipe connections and valves shall be equipped with a secondary containment system.

  (1) The secondary containment system shall consist of:

  (i) Dikes, berms, or retaining walls; and

  (ii) A floor. The floor shall cover the entire area within the dike, berm, or retaining wall, except areas where existing portions of aboveground tanks meet the ground; or

  (iii) An equivalent secondary containment system approved by the Director.

  (2) The entire containment system, including walls and floors, shall be sufficiently impervious to used oil to prevent any used oil released into the containment system from migrating out of the system to the soil, groundwater, or surface water.

  (3) The secondary containment system shall be of sufficient size and volume to prevent any used oil released from tanks and containers described in R315-15-5.5(a), from migrating out of the system to the soil, groundwater, or surface water.

  (4) Water, used oil, or other liquids shall be removed from secondary containment within 24 hours of their discovery.

  (5) Used oil shall not be stored or allowed to accumulate in sumps and similar water-containment structures at the facility. Any used oil in such sumps shall be removed within 24 hours of its discovery.

  (d) Labels.

  (1) Containers and aboveground tanks used to store or process used oil at processing and re-refining facilities shall be labeled or marked clearly with the words "Used Oil."

  (2) Fill pipes used to transfer used oil into underground storage tanks at processing and re-refining facilities shall be labeled or marked clearly with the words "Used Oil."

  (e) Response to releases. Upon detection of a release of used oil to the environment not subject to the requirements of R311-202-1, which incorporates by reference 40 CFR 280, Subpart F, an owner/operator shall comply with R315-15-9.

  (f) Closure.

  (1) Aboveground tanks. Owners and operators who store or process used oil in aboveground tanks shall comply with the following requirements:

  (i) At closure of a tank system, the owner or operator shall remove or decontaminate used oil residues in tanks, contaminated containment system components, contaminated soils, and structures and equipment contaminated with used oil, and manage them as hazardous waste, unless the materials are not hazardous waste under this chapter. Nonhazardous solid waste must be managed in accordance with R315-301-4.

  (ii) If the owner or operator demonstrates that not all contaminated soils can be practicably removed or decontaminated as required in R315-15-5.5(f)(1)(i), then the owner or operator shall close the tank system and perform post-closure care in accordance with the closure and post-closure care requirements that apply to hazardous waste landfills, 40 CFR 265.310 which is adopted by reference.

  (2) Containers. Owners and operators who store used oil in containers shall comply with the following requirements:

  (i) At closure, containers holding used oils or residues of used oil shall be removed from the site;

  (ii) The owner or operator shall remove or decontaminate used oil residues, contaminated containment system components, contaminated soils, and structures and equipment contaminated with used oil, and manage them as hazardous waste, unless the materials are not hazardous waste under R315-261.

  5.6 ANALYSIS PLAN

  Owners or operators of used oil processing/re-refining facilities shall develop and follow a written used oil analysis plan describing the procedures that will be used to comply with the analysis requirements of R315-15-5.4, R315-15-18, and, if applicable, the marketer requirements in R315-15-7.3. The owner or operator shall keep the plan at the facility.

  (a) Rebuttable presumption for used oil in R315-15-5.4. The plan shall specify the following:

  (1) Whether sample analyses documented generator knowledge of the halogen content of the used oil, or both, will be used to make this determination.

  (2) If sample analyses are used to make this determination, the plan shall specify:

  (i) The sampling method used to obtain representative samples to be analyzed. A representative sample may be obtained using either:

  (A) One of the sampling methods in R315-261 Appendix I; or

  (B) A method shown to be equivalent under R315-260-21;

  (ii) The frequency of sampling to be performed, and whether the analysis will be performed onsite or offsite; and

  (iii) The methods used to analyze used oil for the parameters specified in R315-15-5.4; and

  (3) The type of information that will be used to determine the halogen content of the used oil.

  (b) On-specification used oil fuel in R315-15-7.3. At a minimum, the plan shall specify the following if R315-15-7.3 is applicable:

  (1) Whether sample analyses or other information will be used to make this determination;

  (2) If sample analyses are used to make this determination:

  (i) The sampling method used to obtain representative samples to be analyzed. A representative sample may be obtained using either:

  (A) One of the sampling methods in R315-261, Appendix I; or

  (B) A method shown to be equivalent under R315-260-21;

  (ii) Whether used oil will be sampled and analyzed prior to or after any processing/re-refining;

  (iii) The frequency of sampling to be performed, and whether the analysis will be performed on-site or off-site; and

  (iv) The methods used to analyze used oil for the parameters specified in R315-15-7.3.

  (3) The type of information that will be used to make the on-specification used oil fuel determination.

  5.7 TRACKING

  (a) Acceptance. Used oil processors/re-refiners shall keep a written record of each used oil shipment accepted for processing/re-refining. These records shall take the form of a log, invoice, manifest, bill of lading, or other shipping documents. Records for each shipment shall include the following information:

  (1) The name and address of the transporter who delivered the used oil to the processor/re-refiner;

  (2) The name and address of the generator or processor/re-refiner from whom the used oil was sent for processing/re-refining;

  (3) The EPA identification number of the transporter who delivered the used oil to the processor/re-refiner;

  (4) The EPA identification number, if applicable, of the generator or processor/re-refiner from whom the used oil was sent for processing/re-refining;

  (5) The quantity of used oil accepted;

  (6) The date of acceptance; and

  (7) Written documentation that the processor/re-refiner has met the rebuttable presumption requirements of R315-15-5.4 and the PCB testing requirements of R315-15-18.

  (b) Delivery. Used oil processor/re-refiners shall keep a written record of each shipment of used oil that is shipped to a used oil burner, processor/re-refiner, or disposal facility. These records may take the form of a log, invoice, manifest, bill of lading, or other shipping documents. Records for each shipment shall include the following information:

  (1) The name and address of the transporter who delivers the used oil to the burner, processor/re-refiner, or disposal facility;

  (2) The name and address of the burner, processor/re-refiner, or disposal facility that will receive the used oil;

  (3) The EPA identification number of the transporter who delivers the used oil to the burner, processor/re-refiner, or disposal facility;

  (4) The EPA identification number of the burner, processor/re-refiner, or disposal facility that will receive the used oil;

  (5) The quantity of used oil shipped; and

  (6) The date of shipment.

  (c) Record retention. The records described in paragraphs (a) and (b) of this section shall be maintained for at least three years at the permitted facility or other location approved by the Director.

  5.8 OPERATING RECORD AND REPORTING

  (a) Operating record.

  (1) The owner or operator of the processor/re-refiner facility shall keep a written operating record at the facility.

  (2) The following information shall be recorded, as it becomes available, and maintained in the operating record until closure of the facility:

  (i) Records and results of used oil analyses performed as described in the analysis plan required under R315-15-5.6;

  (ii) Summary reports and details of all incidents that require implementation of the contingency plan as specified in R315-15-5.3(b); and

  (iii) Records detailing the mass balance of wastewater entering and leaving the facility. This includes wastewater discharge records. This does not include water used in non-contact cooling processes.

  (b) Reporting. A used oil processor/re-refiner shall report annually March 1 to the Director. The report shall be consistent with the requirements of R315-15-13.5(d).

  5.9 OFF-SITE SHIPMENTS OF USED OIL

  Used oil processors/re-refiners who initiate shipments of used oil offsite shall ship the used oil using a used oil transporter who has obtained an EPA identification number, a permit, and current used oil handler certificate issued by the Director.

  5.10 ACCEPTANCE OF OFF-SITE USED OIL

  Processors accepting used oil from off site shall ensure that transporters delivering used oil to their facility have obtained a current used oil transporter permit and an EPA identification number.

  5.11 MANAGEMENT OF RESIDUES

  Owners and operators who generate residues from the storage, processing, or re-refining of used oil shall manage the residues as specified in R315-15-1.1(e).


R315-15-6. Standards for Used Oil Burners Who Burn Used Oil for Energy Recovery
Latest version.

  6.1 APPLICABILITY

  (a) General. A used oil burner is a person who burns used oil for energy recovery. An on-specification used oil burner is a person who only burns used oil that meets the specifications of R315-15-1.2. Used oil that has not been determined to be on-specification used oil by a Utah-registered marketer shall be managed as off-specification used oil except as described R315-15-2.4. An off-specification used oil burner is a person who burns used oil not meeting the specifications found in R315-15-1.2 for energy recovery. Facilities burning used oil for energy recovery under the following conditions are subject to R315-15-6.1(a) and (b) and R315-15-6.2(b) and (c), but not other portions of R315-15-6:

  (1) The used oil is burned by the generator in an on-site space heater under the provisions of R315-15-2.4;

  (2) The used oil is burned by a processor/re-refiner for purposes of processing used oil, which is considered burning incidentally to used oil processing; or

  (3) The used oil burned by the facility is obtained from a Utah-registered marketer who claims and has demonstrated that the used oil meets the used oil fuel specifications set forth in R315-15-1.2 and who delivers the used oil in the manner set forth in R315-15-7.5(b).

  (b) Other applicable provisions. In addition to the requirements of R315-15-6.1(a), used oil burners who conduct the following activities are subject to the requirements of R315-15 as indicated below.

  (1) Burners who generate used oil shall comply with R315-15-2;

  (2) Burners who transport used oil shall comply with R315-15-4;

  (3) Except as provided in R315-15-6.2(b)(2), burners who process or re-refine used oil shall comply with Section R315-15-5;

  (4) Burners who direct shipments of off-specification used oil from their facility to an off-specification used oil burner or first claim that used oil that is to be burned for energy recovery meets the used oil fuel specifications set forth in R315-15-1.2 shall comply with R315-15-7 and R315-15-13.7;

  (5) Burners who dispose of used oil shall comply with R315-15-8; and

  (6) Burners who collect used oil shall also comply with the collection center requirements in R315-15-3. Burners may only burn used oil collected from other generators if that used oil has been certified to be on-specification used oil by a Utah-registered used oil marketer in compliance with R315-15-7. Burners who collect and burn used oil that is not "do-it-yourselfer" or farmer-generated as described in R315-15-2.1(a)(1) and (4), shall obtain a used oil marketer registration before burning such oil and shall comply with the provisions of R315-15-7.

  (7) Tanks, containers, and piping that previously contained listed hazardous waste. Unless tanks, containers, and piping that previously contained listed hazardous waste are decontaminated as described in R315-261-7 prior to storing used oil, the used oil is considered to have been mixed with the hazardous waste and shall be managed as hazardous waste unless, under the provisions of R315-15-1.1(b), the hazardous waste and used oil mixture is determined not to be hazardous waste.

  (8) Tanks, containers, and piping that previously contained PCB-contaminated material. Unless tanks, containers, and piping that previously contained PCB-contaminated material are decontaminated as described in 40 CFR 761 Subpart S prior to transfer of used oil, the used oil is considered to have been mixed with the PCB-contaminated material and shall be managed as PCB-contaminated material in accordance with R315-15-18.

  (c) Off-specification used oil burner permit. Off-specification used oil burners shall obtain a permit from the Director prior to burning off-specification used oil unless exempted by R315-15-13.6(b)(5). An application for a permit shall contain the information required by R315-15-13.6(b). Off-specification used oil burners shall also obtain a used oil handler certificate in accordance with R315-15-13.8.

  (d) Testing of used oil fuel for PCBs. Used oil to be burned for energy recovery is presumed to contain quantifiable levels, 2 ppm or greater, of PCBs unless a used oil marketer obtains laboratory analyses that the used oil fuel does not contain quantifiable levels of PCBs. The person who first claims that the used oil fuel does not contain a quantifiable level of PCBs shall obtain analyses or other information to support the claim, as described in R315-15-18.

  6.2 RESTRICTIONS ON BURNING

  (a) Off-specification used oil fuel may be burned for energy recovery in only the following devices:

  (1) Industrial furnaces identified in R315-260-10;

  (2) Boilers, as defined in R315-260-10, that are identified as follows:

  (i) Industrial boilers located on the site of a facility engaged in a manufacturing process where substances are transformed into new products, including the component parts of products, by mechanical or chemical processes;

  (ii) Utility boilers used to produce electric power, steam, heated or cooled air, or other gases or fluids for sale;

  (iii) Used oil-fired space heaters provided that the burner meets the provisions of R315-15-2.4; or

  (3) Hazardous waste incinerators subject to regulation under R315-264-340 through 351 or 40 CFR 265.340 through 352 which are adopted by reference.

  (b)(1) With the exception of the aggregation activity described in R315-15-6.2(b)(2), used oil burners may not process used oil unless they also comply with R315-15-5.

  (2) Off-specification used oil burners may aggregate off-specification used oil with virgin oil or on-specification used oil for purposes of burning, but may not aggregate for purposes of marketing on-specification used oil without also complying with the processor/re-refiner requirements in R315-15-5.

  (c) Burning of hazardous waste. Used oil burners may only burn hazardous waste if they are permitted to do so by the Director.

  6.3 NOTIFICATION FOR OFF-SPECIFICATION USED OIL BURNERS

  (a) Identification numbers. Off-specification used oil burners who have not previously complied with the notification requirements of RCRA section 3010 shall comply with these requirements and obtain an EPA identification number.

  (b) Mechanics of notification. An off-specification used oil burner who has not received an EPA identification number may obtain one by notifying the Director of their used oil activity by submitting either:

  (1) A completed EPA Form 8700-12.; or

  (2) A letter to the Director requesting an EPA identification number. The letter shall include the following information:

  (i) Burner company name;

  (ii) Owner of the burner company;

  (iii) Mailing address for the burner;

  (iv) Name and telephone number for the burner point of contact;

  (v) Type of used oil activity; and

  (vi) Location of the burner facility.

  6.4 REBUTTABLE PRESUMPTION FOR USED OIL

  (a) To ensure that used oil managed at a used oil burner facility is not hazardous waste under the rebuttable presumption of Subsection R315-15-1.1(b)(1)(ii), a used oil burner shall determine whether the total halogen content of used oil managed at the facility is above or below 1,000 ppm.

  (b) The used oil burner shall determine if the used oil contains above or below 1,000 ppm total halogens by

  (1) Testing the used oil;

  (2) Applying documented generator knowledge of the halogen content of the used oil in light of the materials and processes used; or

  (3) Using information provided by the processor/re-refiner, if the used oil has been received from a processor/re-refiner subject to regulation under R315-15-5.

  (c) If the used oil contains greater than or equal to 1,000 ppm total halogens, it is presumed to be a hazardous waste because it has been mixed with halogenated hazardous waste listed in R315-261-30 through 33 and 35. The owner or operator may rebut the presumption by demonstrating that the used oil does not contain hazardous waste, for example, by using an analytical method from SW-846, Edition III update IV, to show that the used oil does not contain significant concentrations of halogenated hazardous constituents listed in R315-261 Appendix VIII.

  (1) The rebuttable presumption does not apply to metalworking oils/fluids containing chlorinated paraffins, if they are processed through a tolling arrangement, as described in R315-15-2.5(c), to reclaim metalworking oils/fluids. The presumption does apply to metalworking oils/fluids if such oils/fluids are recycled in any other manner or disposed.

  (2) The rebuttable presumption does not apply to used oils contaminated with chlorofluorocarbons (CFCs) removed from refrigeration units where the CFCs are destined for reclamation. The rebuttable presumption does apply to used oils contaminated with CFCs that have been mixed with used oil from sources other than refrigeration units.

  (d) Record retention. Records of analyses conducted or information used to comply with R315-15-6.4(a), (b), and (c) shall be maintained at the burner facility or another facility approved by the Director for at least 3 years.

  6.5 USED OIL STORAGE AT OFF-SPECIFICATION USED OIL BURNER FACILITIES

  Off-specification used oil burners are subject to all applicable Spill Prevention, Control and Countermeasures, 40 CFR part 112, in addition to the requirements of R315-15-6. Used oil burners are also subject to the standards and requirements of R311-200 through R311-209, Underground Storage Tanks, for used oil stored in underground tanks whether or not the used oil exhibits any characteristics of hazardous waste, in addition to the requirements of R315-15-6.

  (a) Storage units. Off-specification used oil burners may not store used oil in units other than tanks, containers or units subject to regulation under R315-264 and R315-265.

  (b) Condition of units. Containers and aboveground tanks used to store oil at off-specification used oil burner facilities shall be:

  (1) In good condition, with no severe rusting, apparent structural defects, or deterioration; and

  (2) Not leaking.

  (c) Secondary containment. Containers and aboveground tanks used to store off-specification used oil at burner facilities, including their pipe connections and valves, shall be equipped with a secondary containment system.

  (1) The secondary containment system shall consist of:

  (i) Dikes, berms, or retaining walls; and

  (ii) A floor. The floor shall cover the entire area within the dike, berm, or retaining wall, except areas where existing portions of aboveground tanks meet the ground.

  (iii) Other equivalent secondary containment approved by the Director.

  (2) The entire containment system, including walls and floor, shall be of sufficient extent and sufficiently impervious to used oil to prevent any used oil released into the containment system from migrating out of the system to the soil, groundwater, or surface water.

  (3) Any accumulation of water, used oil, or other liquid shall be removed from secondary containment within 24 hours of discovery.

  (4) Used oil shall not be stored or allowed to accumulate in sumps and similar water-containment structures at the facility. Any used oil in sumps and similar water-containment structures shall be removed within 24 hours of its discovery.

  (d) Labels.

  (1) Containers and aboveground tanks used to store off-specification used oil at burner facilities shall be labeled or marked clearly with the words "Used Oil."

  (2) Fill pipes used to transfer off-specification used oil into underground storage tanks at burner facilities shall be labeled or marked clearly with the words "Used Oil."

  (e) Response to releases. Upon detection of a release of used oil to the environment not subject to the requirements of R311-202-1, a burner shall comply with R315-15-9.

  6.6 TRACKING FOR OFF-SPECIFICATION USED OIL FACILITIES

  (a) Acceptance. Off-specification used oil burners shall keep a record of each off-specification used oil shipment accepted for burning. These records may take the form of a log, invoice, manifest, bill of lading, or other shipping documents. Records for each shipment shall include the following information:

  (1) The name and address of the transporter who delivered the used oil to the burner;

  (2) The name and address of the generator or processor/re-refiner from whom the used oil was sent to the burner;

  (3) The EPA identification number of the transporter who delivered the used oil to the burner;

  (4) The EPA identification number, if applicable, of the generator or processor/re-refiner from whom the used oil was sent to the burner;

  (5) The quantity of used oil accepted;

  (6) The date of acceptance; and

  (7) Documentation demonstrating that the transporter has met the rebuttable presumption requirements of R315-15-6.4 and, where applicable, the PCB testing requirements of R315-15-18;

  (b) Record retention. The records described in paragraph (a) of this section shall be maintained for at least three years.

  6.7 NOTICES

  (a) Certification. Before a burner accepts the first shipment of off-specification used oil fuel from a generator, transporter, or processor/re-refiner, the burner shall provide to the generator, transporter, or processor/re-refiner a one-time written and signed notice certifying that:

  (1) The burner has notified the Director of the location and general description of the burner's used oil management activities; and

  (2) The burner will burn the off-specification used oil only in an industrial furnace or boiler identified in R315-15-6.2(a).

  (b) Certification retention. The certification described in R315-15-6.7(a) shall be maintained, at the permitted facility or other location approved by the Director, for three years from the date the burner last receives shipment of off-specification used oil from that generator, transporter, or processor/re-refiner.

  6.8 MANAGEMENT OF RESIDUES AT OFF-SPECIFICATION USED OIL BURNER FACILITIES

  Off-specification used oil burners who generate residues from the storage or burning of used oil shall manage the residues as specified in R315-15-1.1(e).

  6.9 ACCEPTANCE OF OFF-SITE USED OIL

  Off-specification used oil burners accepting used oil from off-site shall ensure that transporters delivering used oil to their facility have obtained a current used oil transporter permit and an EPA identification number.


R315-15-7. Standards for Used Oil Fuel Marketers
Latest version.

  7.1 APPLICABILITY

  (a) Any person who conducts either of the following activities is a used oil fuel marketer and is subject to the requirements of R315-15-7 and R315-15-13.7:

  (1) Directs a shipment of off-specification used oil from their facility to a used oil burner; or

  (2) First determines and claims that used oil that is to be burned for energy recovery meets the used oil fuel specifications set forth in R315-15-1.2.

  (b) The following persons are not used oil fuel marketers subject to R315-15-7:

  (1) Used oil generators, and transporters who transport used oil received only from generators, unless the generator or transporter directs a shipment of off-specification used oil from their facility to a used oil burner. However, processors/re-refiners who burn some used oil fuel for purposes of processing are considered to be burning incidentally to processing. Thus, generators and transporters who direct shipments of off-specification used oil to processors/re-refiners who incidentally burn used oil are not marketers subject to R315-15-7;

  (2) Persons who direct shipments of on-specification used oil and who are not the first person to claim the oil meets the used oil fuel specifications of R315-15-1.2.

  (c) Any person subject to the requirements of R315-15-7 shall also comply with one of the following:

  (1) R315-15-2 - Standards for Used Oil Generators;

  (2) R315-15-4 - Standards for Used Oil Transporters and Transfer Facilities;

  (3) R315-15-5 - Standards for Used Oil Processors and Re-refiners; or

  (4) R315-15-6 - Standards for Used Oil Burners who Burn Off-Specification Used Oil for Energy Recovery.

  (d) A person may not act as a used oil fuel marketer without receiving a registration number and a used oil handler certificate, both issued by the Director as required by R315-15-13.7 and R315-15-13.8.

  7.2 PROHIBITIONS

  A used oil fuel marketer may initiate a shipment of off-specification used oil only to a used oil burner who:

  (a) Has an EPA identification number; and

  (b) Burns the used oil in an industrial furnace or boiler identified in R315-15-6.2(a).

  7.3 ON-SPECIFICATION USED OIL FUEL

  (a) Analysis of used oil fuel. A used oil fuel marketer who is a used oil generator, transporter, transfer facility, processor/re-refiner, or burner may determine that used oil that is to be burned for energy recovery meets the fuel specifications of R315-15-1.2 and the PCB requirements of R315-15-18 by performing analyses or obtaining copies of analyses or other information approved by the Director documenting that the used oil fuel meets the specifications. Used oil is not considered to be on-specification until it has been certified as such by a registered used oil fuel marketer in accordance with the used oil fuel marketer's analysis plan, approved by the Director.

  (b) Record retention. A generator, transporter, transfer facility, processor/re-refiner, or burner who first certifies that used oil that is to be burned for energy recovery meets the specifications for used oil fuel under R315-15-1.2 and the PCB requirements of R315-15-18 shall keep copies of analyses of the used oil, or other information used to make the determination, for three years.

  7.4 NOTIFICATION

  (a) Identification numbers. A used oil fuel marketer subject to the requirements of R315-15-7 who has not previously complied with the notification requirements of RCRA section 3010 shall comply with these requirements and obtain an EPA identification number.

  (b) A marketer who has not received an EPA identification number may obtain one by notifying the Director of their used oil activity by submitting either:

  (1) A completed EPA Form 8700-12; or

  (2) A letter to the Director requesting an EPA identification number. The letter shall include the following information:

  (i) Marketer company name;

  (ii) Owner of the marketer;

  (iii) Mailing address for the marketer;

  (iv) Name and telephone number for the marketer point of contact; and

  (v) Type of used oil activity, e.g., generator directing shipments of off-specification used oil to a burner.

  7.5 TRACKING

  (a) Off-specification used oil delivery. Any used oil marketer who directs a shipment of off-specification used oil to a burner shall keep a record of each shipment of used oil to a used oil burner. These records may take the form of a log, invoice, manifest, bill of lading or other shipping documents. Records for each shipment shall include the following information:

  (1) The name and address of the transporter who delivers the used oil to the burner;

  (2) The name and address of the burner who will receive the used oil;

  (3) The EPA identification number of the transporter who delivers the used oil to the burner;

  (4) The EPA identification number of the burner;

  (5) The quantity of used oil shipped; and

  (6) The date of shipment.

  (b) On-specification used oil delivery. A generator, transporter, transfer facility, processor/re-refiner, or burner who first certifies that used oil that is to be burned for energy recovery meets the fuel specifications under R315-15-1.2 shall keep a record of each shipment of used oil to an on-specification used oil burner. Records for each shipment shall include the following information:

  (1) The name and address of the facility receiving the shipment;

  (2) The quantity of used oil fuel delivered;

  (3) The date of shipment or delivery; and

  (4) A cross-reference to the record of used oil analysis or other information used to make the determination that the oil meets the specifications required under R315-15-7.3(a) and the PCB requirements of R315-15-18.

  (c) Record retention. The records described in R315-15-7.5(a) and (b) shall be maintained for at least three years.

  7.6 NOTICES

  (a) Certification. Before a used oil generator, transporter, transfer facility, or processor/re-refiner directs the first shipment of off-specification used oil fuel to a burner, he shall obtain a one-time written and signed notice from the burner certifying that:

  (1) The burner has notified the Director stating the location and general description of used oil management activities; and

  (2) The burner has obtained an EPA identification number and, if the off-specification used oil is burned in Utah, an off-specification used oil burner permit and current used oil handler certificate from the Director; and

  (3) The burner will burn the off-specification used oil only in an industrial furnace or boiler identified in R315-15-6.2(a).

  (b) Certification retention. The certification described in R315-15-7.6(a) of this section shall be maintained for three years, at the permitted facility or other location approved by the Director, from the date the last shipment of off-specification used oil is shipped to the burner.

  7.7 LABORATORY ANALYSES

  Used oil marketers shall use a Utah-certified laboratory, as specified in R315-15-1.8, to satisfy the analytical requirements of R315-15-7.


R315-15-8. Standards for the Disposal of Used Oil
Latest version.

  8.1 APPLICABILITY

  The requirements of R315-15-8 apply to all used oils that cannot be recycled and are therefore being disposed.

  8.2 DISPOSAL

  (a) Disposal of hazardous used oils. Used oils that are identified as a hazardous waste and that cannot be recycled in accordance with R315-15 shall be managed in accordance with the hazardous waste management requirements of R315-260 through 266, 268, 270, and 273.

  (b) Disposal of nonhazardous used oils. Used oils that are not hazardous wastes and cannot be recycled under Rule R315-15 shall be disposed in a solid waste disposal facility meeting the applicable requirements of Rules R315-301 through R315-318.

  8.3 USE AS A DUST SUPPRESSANT, WEED SUPPRESSANT, OR FOR ROAD OILING

  The use of used oil as a dust suppressant, weed suppressant, or for road oiling or other similar use is prohibited.


R315-15-9. Emergency Controls
Latest version.

  9.1 IMMEDIATE ACTION

  In the event of a release of used oil, the person responsible for the material at the time of the release shall immediately:

  (a) Take appropriate action to minimize the threat to human health and the environment.

  (1) Stop the release;

  (2) Contain the release;

  (3) Clean up and manage properly the released material as described in R315-15-9.3; and

  (4) If necessary, repair or replace any leaking used oil tanks, containers, and ancillary equipment prior to returning them to service.

  (b) Notify the Utah State Department of Environmental Quality, 24-hour Answering Service, 801-536-4123 for used oil releases exceeding 25 gallons, or smaller releases that pose a potential threat to human health or the environment. Small leaks and drips from vehicles are considered de minimis and are not subject to the release clean-up provisions of R315-15-9.

  (c) Provide the following information when reporting the release:

  (1) Name, phone number, and address of person responsible for the release.

  (2) Name, title, and phone number of individual reporting.

  (3) Time and date of release.

  (4) Location of release--as specific as possible including nearest town, city, highway, or waterway.

  (5) Description contained on the manifest and the amount of material released.

  (6) Cause of release.

  (7) Possible hazards to human health or the environment and emergency action taken to minimize that threat.

  (8) The extent of injuries, if any.

  (d) An air, rail, highway, or water transporter who has discharged used oil shall:

  (1) Give notice, if required by 49 CFR 171.15 to the National Response Center, http://nrc.uscg.mil/nrchp.html, 800-424-8802 or 202-426-2675; and

  (2) Report in writing as required by 49 CFR 171.16 to the Director, Office of Hazardous Materials Regulations, Materials Transportation Bureau, Department of Transportation, Washington, D.C. 20590.

  (e) A water, bulk shipment, transporter who has discharged used oil shall give the same notice as required by 33 CFR 153.203 for oil and hazardous substances.

  9.2 EMERGENCY CONTROL VARIANCE

  If a release of used oil requires immediate removal to protect human health or the environment, as determined by the Director, a variance to the used oil transporter permit and used oil handler certificate requirement and the US EPA identification number requirement for used oil transporters may be granted by the Director until the released material and any residue or contaminated soil, water, or other material resulting from the release no longer presents an immediate hazard to human health or the environment, as determined by the Director.

  9.3 RELEASE CLEAN-UP

  The person responsible for the material at the time of the release shall clean up all the released material and any residue or contaminated soil, water or other material resulting from the release or take action as may be required by the Director so that the released material, residue, or contaminated soil, water, or other material no longer presents a hazard to human health or the environment. The Director may require releases to be cleaned up to standards found in US EPA Regional Screening Levels. The cleanup or other required actions shall be at the expense of the person responsible for the release.

  9.4 REPORTING

  Within 15 days after any release of used oil that is reported under R315-15-9.1(b), the person responsible for the material at the time of the release shall submit to the Director a written report that contains the following information:

  (a) The person's name, address, and telephone number;

  (b) Date, time, location, and nature of the incident;

  (c) Name and quantity of material(s) involved;

  (d) The extent of injuries, if any;

  (e) An assessment of actual or potential hazards to human health or the environment, where this is applicable; and

  (f) The estimated quantity and disposition of recovered material that resulted from the incident.


R315-15-10. Financial Requirements
Latest version.

  (a) Used oil activities. An owner or operator of an off-specification burner facility, transportation facility, processing/re-refining facility, or transfer facility, or a group of such facilities, is financially responsible for:

  (1) cleanup and closure costs;

  (2) general liabilities, including operation of motor vehicles, worker compensation and contractor liability; and

  (3) environmental pollution legal liability for bodily injury or property damage to third parties resulting from sudden or non-sudden used oil releases.

  (i)(A) The owner or operator of a permitted used oil facility or operation shall present evidence satisfactory to the Director of its ability to meet these financial requirements.

  (B) The owner or operator shall present with its permit application the information the Director requires to demonstrate its general comprehensive liability coverage.

  (C) The owner or operator shall use the financial mechanisms described in R315-15-12 to demonstrate its ability to meet the financial requirements of R315-15-10(a)(1) and (a)(3).

  (ii) In approving the financial mechanisms used to satisfy the financial requirements, the Director will take into account existing financial mechanisms already in place by the facility if required by R315-264-140 through 151, R315-265-140 through 150, and R311-201-6. Additionally, the Director will consider other relevant factors in approving the financial mechanisms, such as the volumes of used oil handled and existing secondary containment.

  (iii) Financial responsibility, environmental pollution legal liability and general liability coverage shall be provided to the Director as part of the permit application and approval process and shall be maintained until released by Director.

  (iv) Changes in extent, type, or amount of the environmental pollution legal liability and financial responsibility shall be considered a permit modification requiring notification to and approval from the Director.

  (b)(1) Environmental pollution legal liability coverage for third party damages at used oil facilities. Each used oil processor, re-refiner, transfer facility, and off-specification burner shall obtain and maintain environmental pollution liability coverage for bodily injury and property damage to third parties resulting from sudden accidental releases, non-sudden accidental releases, or both, of used oil at its facility. This liability coverage shall be maintained for the duration of the permit or until released by the Director as provided for in R315-15-10.

  (2) Changes in extent, type, or amount of the financial mechanism will be considered a permit modification requiring notification to and approval from the Director. The minimum amount of environmental pollution legal liability coverage using an assurance mechanism as specified in this section for third-party damages shall be:

  (i) For operations where individual volumes of used oil are greater than 55 gallons, such as tanks, storage vessels, used oil processing equipment, and that are raised above grade-level sufficiently to allow for visual inspection of the underside for releases shall be required to obtain coverage in the amount of $1 million per occurrence for sudden releases, with an annual aggregate coverage of $2 million, exclusive of legal defense costs; and

  (ii) For operations in whole or part that do not qualify under Subsection R315-15-10(b)(2)(i), coverage shall be in the amount of $1 million per occurrence for sudden releases, with an annual aggregate coverage of $2 million, and $3 million per occurrence for non-sudden releases, with an annual aggregate coverage of $6 million, exclusive of legal defense costs;

  (iii) For operations covered under Subsection R315-15-10(b)(2)(ii), the owner or operator may choose to use a combined liability coverage for sudden and non-sudden accidental releases in the amount of $4 million per occurrence, with an annual aggregate coverage of $8 million, exclusive of legal defense costs.

  (c) Used oil transporter environmental pollution legal liability coverage for third party damages. Each used oil transporter shall obtain environmental pollution legal liability coverage for bodily injury and property damage to third parties covering sudden accidental releases of used oil from its vehicles and other equipment and containers used during transit, loading, and unloading in Utah, and shall maintain this coverage for the duration of the permit or until released by the Director as provided for R315-15-10. The minimum amount of the coverage for used oil transporters shall be $1 million per occurrence for sudden releases, with an annual aggregate coverage of $2 million, exclusive of legal defense costs. Changes in extent, type, or amount of the liability coverage shall be considered a permit modification requiring notification to and approval from the Director.

  (d) An owner or operator responsible for cleanup and closure under R315-15-11 or environmental pollution legal liability for bodily injury and property damage to third parties under R315-15-10(b) and (c) shall demonstrate its ability to satisfy its responsibility to the Director through the use of an acceptable financial assurance mechanism indicated under R315-15-12.

  (e) Used Oil Collection Centers. Except for DIYers, who are subject to Utah Code Annotated 19-6-718, an owner of a used oil collection center shall be subject to the same liability requirements as a permitted facility under R315-15-10(a) and (b) unless these requirements are waived by the Director. In accordance with Utah Code Annotated 19-6-710, the Director may waive the requirement of proof of liability insurance or other means of financial responsibility that may be incurred in collecting or storing used oil if the following criteria are satisfied:

  (1) The used oil storage tank or container is in good condition with no severe rusting, apparent structural defects or deterioration, and no visible leaks;

  (2) There is adequate secondary containment for the tank or container that is impervious to used oil to prevent any used oil released into the secondary containment system from migrating out of the system;

  (3) The storage tank or container is clearly labeled with the words "Used Oil";

  (4) DIYer log entries are complete including the name and address of the generator, date and quantity of used oil received; and

  (5) Oil sorbent material is readily available on site for immediate cleanup of spills.

  (f) The Director shall waive an owner or operator from its existing financial responsibility mechanism as described in R315-15-10 when:

  (1) The Director approves an alternative mechanism;

  (2) The owner or operator has achieved cleanup and closure according to R315-15-11; or

  (3) The Director determines that financial responsibility is no longer applicable under R315-15.

  (g) State of Utah and Federal government used oil permittees are exempt from the requirements of R315-15-10.


R315-15-11. Cleanup and Closure
Latest version.

  11.1 The owner or operator of a used oil collection, aggregation, transfer, processing/re-refining, or off-specification used oil burning facility shall remove all used oil and used oil residues from the site of operation and return the site to a post-operational land use in a manner that:

  (a) Minimizes the need for further maintenance;

  (b) Controls, minimizes, or eliminates, to the extent necessary to protect human health and the environment, post-closure escape of used oil, used oil constituents, leachate, contaminated run-off, or used oil decomposition products to the ground or surface waters, or to the atmosphere; and

  (c) Complies with the closure requirements of R315-15-11 or supplies evidence acceptable to the Director demonstrating a closure mechanism meeting the requirements of R315-264-140 through 151 and R315-265-140 through 150.

  (d) The permittee shall be responsible for used oil, used oil contaminants, or used oil residual materials that have been discharged or migrate beyond the facility property boundary. The permittee is not relieved of all or any responsibility to cleanup, remedy or remediate a release that has discharged or migrated beyond the facility boundary where off-site access is denied. When off-site access is denied, the permittee shall demonstrate to the satisfaction of the Director that, despite the permittee's best efforts, the permittee was unable to obtain the necessary permission to undertake the actions to cleanup, remedy or remediate the discharge or migration. The responsibility for discharges or migration beyond the facility property boundary does not convey any property rights of any sort, or any exclusive privilege to the permittee.

  11.2 CLEANUP AND CLOSURE PLAN

  (a) Written plan.

  (1) The owner or operator of a used oil transfer, off-specification burner, or processing/re-refining facility shall have a written cleanup and closure plan. The cleanup and closure plan shall be submitted to the Director for approval as part of the permit application.

  (2) When physical or operational conditions at the facility change that result in a change in the nature or extent of cleanup and closure or an increase in the estimated costs of cleanup and closure, the owner or operator shall submit a modified plan for review and approval by the Director.

  (3) Changes in the amount or face value of a financial mechanism that are the result of the annual inflation update from the application of the implicit price deflator multiplier to a permit cleanup and closure plan cost estimate shall not require approval by the Director.

  (4) The adjustment shall be made by recalculating the cleanup closure cost estimate in current dollars or by using an inflation factor derived from the most recent Implicit Price Deflator for Gross Domestic Product published by the U.S. Department of Commerce, Bureau of Economic Analysis in its Survey of Current Business as specified in R315-264-145(b)(1) and (2). The inflation factor is the incremental increase of the latest published annual Deflator to the Deflator for the previous year divided by the previous year Deflator. The first adjustment is made by multiplying the cleanup closure cost estimate by the inflation factor. The result is the adjusted cleanup closure cost estimate. Subsequent adjustments are made by multiplying the latest adjusted cleanup closure cost estimate by the latest inflation factor.

  (b) Content of plan. The plan shall identify steps necessary to perform partial or final cleanup and closure of the facility at any point during its active life.

  (1) The cleanup and closure plan shall be based on third-party, direct-estimated costs or on third-party costs using RS Means methods, applications, procedures, and use cost values applicable to the location of the facility and include, at least:

  (i) A description of how each used oil management unit at the facility will be closed.

  (ii) A description of how final cleanup and closure of the facility will be conducted. The description shall identify the maximum extent of the operations that will be cleaned, closed, or both during the active life of the facility.

  (iii) The highest cost estimate of the maximum inventory of used oil to be stored onsite at any one time during the life of the facility and a detailed description of the methods to be used during partial cleanup and closure final cleanup and closure, or both, including, but not limited to, methods for removing, transporting, or disposing of all used oil, and identification of the off-site used oil facilities to be used, if applicable.

  (iv) A detailed description of the steps needed to remove or decontaminate all used oil and used oil residues and contaminated containment system components, equipment, structures, and soils during partial or final cleanup and closure, including procedures for cleaning equipment and removing contaminated soils, methods for sampling and testing surrounding soils, and criteria for determining the extent of decontamination required to satisfy closure. This description shall address the management and disposal of all residues resulting from the decontamination activity, including, but not limited to, rinse waters, rags, personal protective equipment, small hand implements, vehicles, and mechanized equipment.

  (v) A detailed description of other activities necessary during the cleanup and closure period to ensure that all partial closures shall satisfy the final cleanup and closure plan.

  (vi) A cleanup and closure cost estimate and a mechanism for financial responsibility to cover the cost of cleanup and closure

  (vii) State of Utah and Federal government used oil permittees are exempt from the requirements of R315-15-11(b)(1)(vi).

  (2) The owner or operator shall update its cleanup and closure plan cost estimate and provide the updated estimate to the Director, in writing, within 60 days following a facility modification that causes an increase in the amount of the financial responsibility required under R315-15-10. Within 30 days of the Director's approval of a permit modification for the cleanup and closure plan that would result in an increased cost estimate, the owner or operator shall provide to the Director:

  (i) evidence that the financial assurance mechanism amount or value includes the cleanup and closure cost estimate increase; or

  (ii) other mechanisms covering the increased closure plan cost estimate and a summary document indicating the multiple financial mechanisms, by mechanism name, account number, and the amounts to satisfy R315-15-10 and 11.

  (c) The owner or operator shall update the cleanup and closure cost estimate to adjust for inflation and include the updated estimate in the permitted facility's annual report due by March 1st of each year, using either:

  (1) the multiplier formed from the gross domestic product implicit price deflator ratio of the current calendar year to the past calendar year as published by the federal government Bureau of Economic Analysis; or

  (2) new cleanup and closure cost estimate from the recalculation of the cleanup and closure plan costs to account for all changes in scope and nature of the facility or facilities, in current dollars.

  11.3 TIME ALLOWED TO INITIATE CLOSURE

  (a) The owner or operator shall initiate closure in accordance with the approved cleanup and closure plan and notify the Director that closure has been initiated:

  (1) Within 90 days after the owner or operator receives the final volume of used oil; or

  (2) Within 90 days after the Director revokes the facility's used oil permit.

  (b) During the cleanup and closure period or at any other time, if the Director determines that the owner or operator has failed to comply with R315-15, the Director may, after 30 days following written notice to the owner or operator, draw upon the financial mechanism associated with the cleanup and closure plan for the facility or facilities covered by the financial responsibility requirements of R315-15-10.

  11.4 CERTIFICATION OF CLOSURE

  (a) Within 60 days of completion of cleanup and closure, the owner or operator of a permitted used oil facility shall submit to the Director, by registered mail, a certification that the used oil facility has been cleaned and closed in accordance with the specifications in the approved cleanup and closure plan. The certification shall be signed by the owner or operator and by an independent, Utah-registered professional engineer.

  (b) The Director shall make the determination of whether cleanup and closure has been completed according to the cleanup and closure plan and R315-15.


R315-15-12. Financial Assurance
Latest version.

  12.1 DEFINITIONS

  For the purposes of R315-15-12, the following definitions apply:

  (a) "Existing used oil facility" means any used oil transfer facility, off-specification burner, or used oil processing/re-refining facility in operation on July 1, 1993 under a used oil operating permit issued by the Division of Oil, Gas and Mining and in effect on or before June 30, 1993. An existing used oil facility is also required to obtain a permit from the Director in accordance with R315-15-13.

  (b) "New used oil facility" means any used oil transfer, off-specification burner, or used oil processing/re-refining facility that was not in operation as a used oil facility on July 1, 1993, and received an operating permit in accordance with R315-15-13 from the Director after July 1, 1993.

  (c) "Financial assurance mechanism" means "reclamation surety" as used in Utah Code Annotated 19-6-709 and 19-6-710 of the Used Oil Management Act.

  12.2 APPLICABILITY

  (a) The owner or operator of an existing or new used oil facility requiring a permit under R315-15-13 shall establish a financial assurance mechanism as evidence of financial responsibility under R315-15-10 sufficient to assure cleanup and closure of the facility in conformance with R315-15-11.1 with one or more of the financial assurance mechanisms of R315-15-12.3 prior to receiving a permit from the Director.

  (b) Any increase in capacity to store or process used oil at a used oil facility permitted by the Director, above the storage or processing capacity identified in the permit application approved by the Director, shall require the owner or operator of the permitted used oil facility to increase the amount or face value of the financial assurance mechanism to meet the additional capacity. The additional amount or increase in face value of financial assurance mechanism shall be in place and effective before operation of the increased storage or processing capacity and shall meet the requirements of R315-15-12.3 and R315-15-12.4.

  (c) DIYer used oil collection centers, generator used oil collection centers, and used oil aggregation points are not required to post a financial assurance mechanism, but are subject to the cleanup and closure requirements of R315-15-10 and R315-15-11 unless they have received a waiver in writing from the Director as identified in R315-15-10(e).

  12.3 FINANCIAL ASSURANCE MECHANISMS

  (a) Any financial assurance mechanism used to show financial responsibility under R315-15-10 and 11 for an existing or new used oil facility shall:

  (1) be legally valid, binding, and enforceable under Utah and federal law;

  (2) be approved by the Director;

  (3) ensure that funds will be available in a timely fashion for:

  (i) completing all cleanup and closure activities indicated in the closure plan of the permit approved by the Director; and

  (ii) environmental pollution legal liability for third party damages for bodily injury and property damage resulting from a sudden or non-sudden accidental release of used oil from or arising from permitted operations; and

  (4) require a written notice sent by certified mail to the Director 120 days prior to cancellation or termination of the financial mechanism.

  (5) be updated each year to adjust for inflation, using either:

  (i) the gross domestic product implicit price deflator ratio of the increase of the current calendar year to the past calendar year or

  (ii) a new estimated cleanup and closure cost estimate recalculated to account for all changes in scope and nature of the permitted operation.

  (b) The owner or operator of an existing or new used oil facility shall establish a financial assurance mechanism for cleanup and closure by one of the following mechanisms and shall submit a signed original or an original signed duplicate of the financial assurance mechanism to the Director for approval as part of the permit application:

  (1) Trust Fund.

  (i) The trustee shall be an entity that has the authority to act as a trustee and whose operations are regulated and examined by a federal or state agency.

  (ii) A signed original or an original signed duplicate of the trust agreement and accompanied by a formal certification of acknowledgement shall be submitted to the Director.

  (iii) For trust funds that are fully funded at the time of permit approval, an annual trust valuation shall be certified and submitted to the Director. The permittee shall provide evidence annually, upon the anniversary of the trust agreement, that the trust remains fully funded.

  (iv) For trust funds not fully funded at the time of permit approval by the Director, incremental payments into the trust fund shall be made annually by the owner or operator to fully fund the trust within five years of the Director's approval of the permit as follows:

  (A) initial payment value shall be the initial cleanup and closure cost estimate value divided by the pay-in period, not to exceed five years, and

  (B) next payment value shall be the difference of the approved current cleanup and closure cost estimate less the trust fund value, all divided by the remaining number of years in the pay-in period, and

  (C) subsequent next payments shall be made into the trust fund annually on or before the anniversary date of the initial payment made into the trust fund and reported in accordance with the approved trust agreement, and

  (D) no later than 30 days after the last incremental payment to fully fund the trust, the permittee shall provide proof to the Director that the trust fund has been fully funded according to the current permitted cleanup and closure cost estimate.

  (E) The facility shall submit an annual valuation of the trust to the Director on or before the anniversary date of the trust.

  (v) For a new used oil facility, the payment into the trust fund shall be made before the initial receipt of used oil.

  (vi) The owner or operator, or other person authorized to conduct cleanup and closure activities may request reimbursement from the trustee for cleanup and closure completed when approved in writing by the Director.

  (vii) The request for reimbursement may be granted by the trustee as follows:

  (A) only if sufficient funds exist to cover the reimbursement request; and

  (B) if justification and documentation of the cleanup and closure expenditures are submitted to and approved by the Director in writing prior to the trustee granting reimbursement.

  (viii) The Director may cancel the incremental trust funding option at any time and require the permittee to provide either a fully funded trust or other cleanup and closure financial mechanism as provided in R315-15-12 under the following conditions:

  (A) upon the insolvency of the permittee, or

  (B) when a violation of R315-15-10, 11 or 12 has been determined.

  (ix) The trust agreement shall follow the wording provided by the Director as identified in R315-15-17.2.

  (2) Surety Bond Guaranteeing Payment.

  (i) The bond shall be effective before the initial receipt of used oil.

  (ii) The surety company issuing the bond shall, at a minimum, be among those listed as acceptable sureties on Federal bonds in Circular 570 of the U.S. Department of the Treasury and the owner or operator shall notify the Director that a copy of the bond has been placed in the operating record.

  (iii) The penal sum of the bond shall be in an amount at least equal to the cleanup and closure cost estimate developed under R315-15-11.2.

  (iv) Under the terms of the bond, the surety shall become liable on the bond obligation when the owner or operator fails to perform as guaranteed by the bond.

  (v) The owner or operator shall establish a standby trust agreement at the time the bond is established.

  (A) The standby trust agreement shall meet the requirements of R315-15-12.3(b)(1), except for R315-15-12.3(b)(1)(iii), (viii), and (ix) and the standby trust agreement shall follow the wording provided by the Director as identified in R315-15-17.14.

  (B) Payment made under the terms of the bond shall be deposited by the surety directly into the standby trust agreement and payments from the standby trust fund shall be approved by the trustee with the written concurrence of the Director.

  (vi) The surety bond shall automatically be renewed on the expiration date unless cancelled by the surety company 120 days in advance by sending both the bond applicant and the Director a written cancellation notice by certified mail.

  (vii) The bond applicant may terminate the bond for nonpayment of fee by providing written notice, by certified mail, to the Director 120 days prior to termination.

  (viii) Any change to the form or content of the surety bond shall be submitted to the Director for approval and acceptance.

  (ix) The surety bond shall follow the language provided by the Director found in R315-15-17.3.

  (3) Letter of Credit

  (i) The letter of credit shall be effective before the initial receipt of used oil

  (ii) The financial institution issuing the letter of credit shall be an entity that has the authority to issue letters of credit and whose letter of credit operations are regulated and examined by a state or federal agency.

  (iii) The letter of credit shall be issued in an amount at least equal to the cleanup and closure cost estimate developed under R315-15-11.2.

  (iv) The owner or operator shall establish a standby trust agreement at the time the letter of credit is established.

  (A) The standby trust agreement shall meet the requirements of R315-15-12.3(b)(1), except for Subsections R315-15-12.3(b)(1)(iii), (viii), and (ix) and the standby trust agreement shall follow the language incorporated by reference in R315-15-17.14.

  (B) Payment made under the terms of the letter of credit shall be deposited by the surety directly into the standby trust and payments from the standby trust fund shall be approved by the trustee with the written concurrence of the Director.

  (v) The letter of credit shall follow the wording provided by the Director as identified in R315-15-17.4.

  (4) Insurance.

  (i) The insurance shall be effective before the initial receipt of used oil.

  (A) Insurance coverage period shall be the earliest date of permit issuance or a retroactive date established by the earliest period of coverage for any financial assurance mechanism.

  (ii) At a minimum, the insurer shall be licensed to transact the business of insurance, or eligible to provide insurance as an excess or surplus lines insurer, in one or more states.

  (iii) The insurance policy shall guarantee that funds will be available to perform the cleanup and closure activities approved by the Director.

  (iv) The policy shall guarantee that the insurer will be responsible for the paying out of funds to the owner or operator or person authorized to conduct the cleanup and closure activities, as approved by the Director, up to an amount equal to the face amount of the policy. Payment of any funds by the insurer shall be made with the written concurrence of the Director.

  (A) The Insurer shall establish at a standby trust agreement for only the benefit of the Director when the Director notifies the Insurer that the Director is making a claim, as provided for in R315-15, for cleanup and closure of a permitted used oil transfer, processor, re-refiner, or off-specification burner facility.

  (B) The Insurer shall place the face value of the applicable coverage in the trust within 30 days of establishing the standby trust agreement.

  (C) The standby trust agreement shall meet the requirements of R315-15-12.3(b)(1), except for R315-15-12.3(b)(1)(iii), (iv), (v), (viii), and (xi), and the standby trust agreement shall follow the language provided by the Director incorporated by reference in R315-15-17.14.

  (v) The insurance policy shall be issued for a face amount at least equal to the cleanup and closure cost estimate developed under R315-15-11.2.

  (vi) An owner or operator, or other person authorized by the Director, may receive reimbursements for cleanup and closure activities completed if:

  (A) the value of the policy is sufficient to cover the reimbursement request; and

  (B) justification and documentation of the cleanup and closure expenditures are submitted to and approved by the Director, prior to receiving reimbursement.

  (vii) Each policy shall contain a provision allowing assignment of the policy to a successor owner or operator.

  (viii) The insurance policy shall provide that the insurer may not cancel, terminate, or fail to renew the policy except for failure to pay the premium. If there is a failure to pay the premium, the insurer may cancel the policy by sending notice of cancellation by certified mail to the owner or operator and the Director 120 days in advance of cancellation. If the insurer cancels the policy, the owner or operator shall obtain an alternate financial assurance mechanism meeting the requirements for financial responsibility under R315-15-10 and of this subsection within 60 days of notice of cancellation of the policy.

  (ix) The policy coverage amount for cleanup and closure is exclusive of legal and defense costs.

  (x) Bankruptcy or insolvency of the Insured shall not relieve the Insurer of its obligations under the policy.

  (xi) The Insurer as first-payer is liable for the payment of amounts within any deductible, retention, self-insured retention (SIR), or reserve applicable to the policy, with a right of reimbursement by the Insured for any such payment made by the Insurer. This provision does not apply with respect to that amount of any deductible, retention, self-insured retention, or reserve for which coverage is otherwise demonstrated as specified in R315-15-12.

  (xii) Whenever requested by the Director, the Insurer agrees to furnish to the Director a signed duplicate original of the policy and all endorsements.

  (xiii) Cancellation of the policy, whether by the Insurer, the Insured, a parent corporation providing insurance coverage for its subsidiary, or by a firm having an insurable interest in and obtaining liability insurance on behalf of the owner or operator of the used oil management facility, will be effective only upon written notice and only after the expiration of 120 days after a copy of such written notice is received by the Director for those facilities that are located in Utah.

  (xiv) Any other termination of the policy will be effective only upon written notice and only after the expiration of 120 days after a copy of such written notice is received by the Director for those facilities that are located in Utah.

  (xv) All policy provisions related to R315-15 shall be construed in accordance with the laws of the State of Utah. In the event of the failure of the Insurer to pay any amount claimed to be due hereunder, the Insurer and the Insured will submit to the jurisdiction of the appropriate court of the State of Utah, and will comply with all the requirements necessary to give such court jurisdiction. All matters arising hereunder, including questions related to the interpretation, performance and enforcement of this policy, shall be determined in accordance with the law and practice of the State of Utah (notwithstanding Utah conflicts of law rules).

  (xvi) Endorsement(s) added to, or removed from the policy that have the effect of affecting the environmental pollution liability language, directly or indirectly, shall be approved in writing by the Director before said endorsement(s) become effective.

  (xvii) Neither the Insurer nor the Insured shall contest the state of Utah's use of the drafting history of the insurance policy in a judicial interpretation of the policy or endorsement(s) to said policy.

  (xviii) The Insurer shall establish a standby trust fund for the benefit of the Director at the time the Director first makes a claim against the insurance policy.

  (A) The standby trust fund shall meet the requirements of R315-15-12.3(b)(1), except for item R315-15-12.3(b)(1)(iii), (iv), (v), (viii), and (ix) and the standby trust agreement shall follow the wording found in R315-15-17.14.

  (B) Payment made under the terms of the insurance policy shall be deposited by the Insurer as grantor directly into the standby trust fund and payments from the trust fund shall be approved by the trustee with the written concurrence of the Director.

  (5) The owner or operator of an existing or new used oil facility may establish a financial assurance mechanism by a combination of the above mechanisms as approved by the Director.

  (c) The owner or operator of an existing or new used oil facility or operation shall establish a financial assurance mechanism for bodily injury and property damage to third parties resulting from sudden and/or non-sudden accidental releases of used oil from a permitted used oil facility or operation as follows:

  (1) An owner or operator that is a used oil processor, transfer facility, or off-specification burner, or a group of such facilities regulated under R315-15 shall demonstrate financial responsibility for bodily injury and property damage to third parties caused by sudden and/or non-sudden accidental release of used oil arising from operations or operations of the facility or group of facilities shall have and maintain liability coverage in the amount as specified in R315-15-10(b). This liability coverage shall be demonstrated by one or more of the financial mechanisms in R315-15-12.3(c)(3).

  (2) An owner or operator that is a used oil transporter regulated under R315-15, must demonstrate financial responsibility for bodily injury and property damage to third-parties resulting from sudden release of used oil arising from transit, loading and unloading, to or from facilities within Utah. The owner or operator shall maintain liability coverage for sudden accidental occurrences in the amount specified in R315-15-10(c). This liability coverage shall be demonstrated by one or more of the financial mechanisms in R315-15-12.3(c)(3).

  (3) The owner or operator shall demonstrate compliance with R315-15-10(b) or (c) by using one or more of the following financial assurance mechanisms:

  (i) Insurance. The owner or operator shall follow the wording provided by the Director identified in R315-15-17.5 through R315-15-17.9, as may be applicable.

  (ii) Trust. The owner or operator shall follow the wording provided by the Director identified in R315-15-17.12.

  (iii) Surety Bond. The owner or operator shall follow the wording provided by the Director identified in R315-15-17.11.

  (iv) Letter of Credit. The owner or operator shall follow the wording provided by the Director identified in R315-15-17.10.

  (d) Adjustments by the Director. If the Director determines that the levels of financial responsibility required by R315-15-10(b) or (c), as applicable are not consistent with the degree and duration of risk associated with used oil operations or facilities, the Director may adjust the level of financial responsibility required under R315-15-10(b) or (c), as applicable, as may be necessary to protect human health and the environment. This adjusted level will be based on the Director's assessment of the degree and duration of risk associated with the used oil operations or facilities. In addition, if the Director determines that there is a significant risk to human health and the environment from non-sudden release of used oil resulting from the used oil operations or facilities, the Director may require that an owner or operator of the used oil facility or operation comply with R315-15-10(b) and (c), as applicable. An owner or operator must furnish, within a reasonable time to the Director when requested in writing, any information the Director requests to determine whether cause exists for an adjustment to the financial responsibility under R315-15-10(b) or (c) with the used oil operations or facilities. Failure to provide the requested information as and when requested under this section may result in the Director revoking the owner's or operator's used oil permit(s). Any adjustment of the level or type of coverage for a facility that has a permit will be treated as a permit modification.

  (e) When the owner or operator of a permitted used oil facility or operation believes that its responsibility for cleanup and closure or for environmental pollution liability as described in R315-15-10(d) has changed, it may submit a written request to the Director to modify its permit to reflect the changed responsibility.

  (f) The Director may release the requirement for cleanup and closure financial assurance after the owner or operator has clean-closed the facility according to R315-15-11.

  (g) The owner or operator of a permitted used oil facility or operation may request the Director to modify its permit to change its financial assurance mechanism or mechanisms as described in R315-15-12.

  (h) The Director may modify the permit to change financial assurance mechanism or mechanisms after the owner or operator has established a replacement financial assurance mechanism or mechanisms acceptable to the Director.

  (i) Incapacity of owners or operators, guarantor, or financial institution. An owner or operator of a permitted used oil facility or operation shall notify the Director by certified mail within ten days of the commencement of a bankruptcy proceeding naming the owner or operator as debtor.

  (1) An owner or operator who fulfills the financial responsibility requirements by obtaining a trust fund, surety bond, letter of credit, or insurance policy will be considered to be without the required financial responsibility or liability coverage in the event of:

  (i) bankruptcy of the trustee or issuing institution; or

  (ii) a suspension or revocation of the authority of the trustee institution to act as trustee; or

  (iii) a suspension or revocation of the authority of the institution to issue a surety bond, a letter of credit, or an insurance policy.

  (2) The owner or operator of a permitted used oil facility or operation must establish other financial responsibility or liability coverage within 60 days after such an event.

  12.4 ANNUAL UPDATE OF CLOSURE COST ESTIMATE AND FINANCIAL ASSURANCE MECHANISM

  (a) The financial responsibility information required by R315-15-10, 11, and 12 and submitted to the Director with the initial permit application for a used oil facility or operation, or information provided as part of subsequent modifications to the permit made thereafter, shall be updated annually.

  (b) The following annual updated financial responsibility information for the previous calendar year shall be submitted to the Director by March 1 of each year for each permitted facility or operation:

  (1) The cleanup and closure cost estimate shall be based on a third party performing cleanup and closure of the facility to a post-operational land use in accordance with R315-15-11.1.

  (2) The financial assurance mechanism shall be adjusted to reflect the new cleanup and closure cost estimate.

  (3) The type of financial assurance mechanism, its current face value, and corresponding financial institution's instrument control number shall be provided.

  (4) The type of environmental pollution liability financial responsibility for third-party damage mechanism shall be provided, including:

  (i) policy number or other mechanism control number,

  (ii) effective date of policy or other mechanism, and

  (iii) coverage types and amounts.

  (5) The type of general liability insurance information shall be provided, including:

  (i) policy number,

  (ii) date of policy, effective date of policy, retroactive date of coverage, if applicable, and

  (iii) coverage types and amounts.

  (c) Other type of information deemed necessary to evaluate compliance with a permitted used oil facilities or operations and R315-15-10, 11, and 12, shall be provided upon request by the Director.


R315-15-13. Registration and Permitting of Used Oil Handlers
Latest version.

  13.1 DO-IT-YOURSELFER USED OIL COLLECTION CENTERS TYPES A AND B

  (a) Applicability. A person may not operate a do-it-yourselfer (DIYer) Type A or B used oil collection center without holding a registration number issued by the Director.

  (b) General. The application for a registration number shall include the following information regarding the DIYer used oil collection center:

  (1) the name and address of the operator;

  (2) the location of the center;

  (3) the type of storage and secondary containment to be used;

  (4) the status of the business, zoning, or other licenses and permits if required by federal, state and local governmental entities;

  (5) a spill containment plan in the event of a release of used oil; and

  (6) proof of insurance or other means of financial responsibility for liabilities that may be incurred in collecting or storing used oil.

  (c) Waiver of proof of insurance or other means of financial responsibility for liabilities that may be incurred in collecting or storing used oil. In accordance with Utah Annotated 19-6-710, the Director may waive the requirement of proof of liability insurance or other means of financial responsibility if the following criteria are satisfied:

  (1) The used oil storage tank or container is in good condition with no severe rusting, apparent structural defects or deterioration, and no visible leaks;

  (2) There is adequate secondary containment for the tank or container that is impervious to used oil to prevent any used oil released into the secondary containment system from migrating out of the system to the soil, groundwater or surface water;

  (3) The storage tank or container is clearly labeled with the words "Used Oil;"

  (4) DIYer log entries are complete including the name and address of the generator, date and quantity of used oil received;

  (5) EPA-approved test kits for total halogens are readily available and operators are trained to perform halogen tests on any used oil received that may have been mixed with hazardous waste; and

  (6) Oil sorbent material is readily available on site for immediate clean-up of spills.

  (d) Changes in information. The owner or operator of the facility shall notify the Director in writing of any changes in the information submitted to apply for a registration number within 20 days of the change.

  13.2 GENERATOR USED OIL COLLECTION CENTERS TYPES C AND D

  (a) Applicability. A person may not operate a generator used oil collection center Type C or D without holding a registration number issued by the Director.

  (b) General. The application for registration shall include the following information regarding the generator used oil collection center:

  (1) the name and address of the operator;

  (2) the location of the center;

  (3) whether the center will accept DIYer used oil;

  (4) the type of storage and secondary containment to be used;

  (5) the status of the business, zoning, or other licenses and permits if required by federal, state and local governmental entities;

  (6) a spill containment plan in the event of a release of used oil; and

  (7) proof of insurance or other means of financial responsibility for liabilities that may be incurred in collecting or storing used oil.

  (c) Permit. Waiver of proof of insurance or other means of financial responsibility for liabilities that may be incurred in collecting or storing used oil. In accordance with Utah Code Annotated 19-6-710, the Director may waive the requirement of proof of liability insurance or other means of financial responsibility if the following criteria are satisfied:

  (1) The used oil storage tank or container is in good condition with no severe rusting, apparent structural defects or deterioration, and no visible leaks;

  (2) There is adequate secondary containment for the tank or container that is impervious to used oil to prevent any used oil released into the secondary containment system from migrating out of the system to the soil, groundwater or surface water;

  (3) The storage tank or container is clearly labeled with the words "Used Oil;"

  (4) DIYer log entries are complete including the name and address of the generator, date and quantity of used oil received;

  (5) EPA-approved test kits for total halogens are readily available and operators are trained to perform halogen tests on any used oil received that may have been mixed with hazardous waste; and

  (6) Oil sorbent material is readily available on site for immediate clean up of spills.

  (d) Changes in information. The owner or operator of the facility shall notify the Director in writing of any changes in the information submitted to apply for a registration number within 20 days of the change.

  13.3 USED OIL AGGREGATION POINTS

  (a) Applicability. A person may operate a used oil aggregation point without holding a registration number issued by the Director unless that aggregation point also accepts used oil from household do-it-yourselfers (DIYers) or other generators.

  (b) If an aggregation point accepts used oil from household DIYers, it must register with the Director as a DIYer collection center and comply with the DIYer standards in Section R315-15-3.1.

  (c) If an aggregation point accepts used oil from other generators it must register with the Director as a generator collection center and comply with the standards in R315-15-3.2.

  13.4 USED OIL TRANSPORTERS AND USED OIL TRANSFER FACILITIES

  (a) Applicability. Except as provided by R315-15-13.4(f), a person may not operate as a used oil transporter without holding a used oil transporter permit issued by the Director. A person shall not operate a used oil transfer facility without holding a used oil transfer facility permit specific to that facility, issued by the Director.

  (b) General. The application for a permit shall include the following information:

  (1) The name and address of the operator;

  (2) The location of the transporter's base of operations and the location of any transfer facilities, if applicable;

  (3) Maps of all transfer facilities, if applicable;

  (4) The methods to be used for collecting, storing, and delivering used oil;

  (5) The methods to be used to determine if used oil received by the transporter or facility is on-specification or off-specification and how the transporter will comply with the rebuttable requirements of R315-15-4.5;

  (6) The type of containment and the volume, including type and number of storage vessels to be used and the number and type of transportation vehicles, if applicable;

  (7) The methods of disposing of any waste by-products;

  (8) The status of business, zoning, and other applicable licenses and permits if required by federal, state, and local government entities;

  (9) An emergency spill containment plan, including a list of spill containment equipment to be carried in vehicles used to transport used oil and spill containment equipment maintained at the used oil transfer facility, and how the transporter shall comply with the requirements of R315-15-9;

  (10) Proof of liability insurance or other means of financial responsibility for liabilities that may be incurred in collecting, transporting, or storing used oil;

  (11) Proof of form and amount of reclamation surety for any facility used in conjunction with transportation or storage of used oil;

  (12) A closure plan meeting the requirements of R315-15-11;

  (13) Proof of applicant's ownership of any property and facility used for storage of used oil or, if the property and facility is not owned by the applicant, the owners' written statement acknowledging the activities specified in the application;

  (14) For transfer facility permit applications, tank certification in accordance with R315-264-190 through 200 for used oil storage tanks at the transfer facility;

  (15) For transfer facility permit applications, a facility piping and instrument drawing certified by a Professional Engineer;

  (16) If rail transport is part of the application, a loading/off-loading plan for rail tanker cars used to transport used oil. This plan shall include detailed procedures to be followed to minimize the potential for releases and on-site accidents. At a minimum, the following items shall be addressed:

  (i) Personal safety equipment;

  (ii) Coordination with railroad to ensure exclusive rights to the loading track during the entire period of loading/offloading;

  (iii) A minimum number and qualification of workers involved in the loading or off-loading operations;

  (iv) Braking and blocking of rail car wheels;

  (v) Procedures for Depressurizing tank car prior to opening manhole covers and outlet valves;

  (vi) The sequence of valve openings and closings on any hosing or piping involved in the loading or off-loading process,

  (vii) A description of how and where pipe and hose fitting will be attached, including a description of which rail car valves/openings will be used;

  (viii) Use of catchment container to collect any used oil released from hoses, valves, and pipes during and following the loading/offloading operation;

  (ix) Measures to insure ignition sources are not present;

  (x) Procedures for cleanup of any spills that occur during the loading/offloading operations; and

  (xi) Other site-specific requirements required by the Director to protect human health and the environment.

  (c) Permit fees. Registration and permitting fees are established under the terms and conditions of Utah Code Annotated 63J-1-504. A copy of the Division's Fee Schedule is available upon request. Payment of appropriate fees is required prior to issuance of permit approvals and annual used oil handler certificates.

  (d) Annual Reporting. Each transporter and transfer facility shall submit an annual report to the Director of its activities during the calendar year. The annual report shall be submitted to the Director no later than March 1, of the year following the reported activities. The Annual report shall either be submitted on a form provided by the Director or shall contain the following information:

  (1) the EPA identification number, name, and address of the transporter/transfer facility;

  (2) the calendar year covered by the report;

  (3) the total amount of used oil transported;

  (4) the itemized amounts and types of used oil transferred to permitted transporters and transfer facilities, used oil processors/re-refiners, off-specification used oil burners, and used oil fuel marketers; and

  (5) the itemized amounts and types of used oil transferred inside and outside the state, indicating the state to which used oil is transferred, and the specific name, address and telephone number of the operations or facility to which used oil was transferred.

  (e) Changes in information. The owner or operator of the facility shall notify the Director in writing of any changes in the information submitted to apply for a permit within 20 days of the change.

  (f) Transporter and Transfer Facility Permit by rule. Notwithstanding any other provisions of R315-15-13.4, a used oil generator who self-transports used oil generated by that generator at a non-contiguous operation to a central collection facility in the generator's own service vehicles in quantities exceeding 55 gallons shall be deemed to have an approved used oil transporter permit or used oil transfer facility permits, or both if the generator meets all applicable requirements of R315-15-13.4(f)(1) through (4).

  (1) All used oil transporters or transfer facilities who qualify for a permit by rule shall submit a notification to the Director of their intent to operate under R315-15-13.4(f) and comply with the following conditions:

  (i) The generator's facility is defined under the North American Industry Classification System (NAICS), published, in 2017 Revision, by the US Economic Classification Policy Committee, with a NAICS code of 21 (Mining), 22 (Utilities), 23 (Construction), 485111 (Mixed Mode Transit Systems), or 541360 (Geophysical Surveying and Mapping Services);

  (ii) The generator self-transports and delivers the used oil to facilities that the generator owns, operates, or both.

  (iii) The generator notifies the Director with the information required by R315-15-13.4(b)(1) through (10); and

  (iv) The generator complies with R315-15-4.3, R315-15-4.4(b) through (d), R315-15-4.6(b) through (f), R315-15-4.7(b) and (d), and R315-15-4.8.

  (2) A generator who self-transports used oil in accordance with R315-15-13.4(f)(1)and who burns all the collected used oil for energy recovery is deemed to be approved by rule to operate as a used oil transporter for that activity if the following additional conditions are met:

  (i) The generator only burns the self-collected used oil for energy recovery at that generator's own central collection facility.

  (ii) The generator registers as a used oil fuel marketer in accordance with R315-15-13.7 and complies with R315-15-7.

  (3) A generator who self-transports used oil in accordance with R315-15-13.4(f)(1) and only stores the used oil for subsequent collection by permitted used oil transporters is deemed to be approved by rule to operate as a used oil transporter and transfer facility for that activity if the following additional conditions are met:

  (i) The generator arranges for permitted used oil transporters to collect the generator's used oil.

  (ii) The self-transported used oil is not stored at the generator's facility longer than 35 days. If the self-transported used oil is stored longer than 35 days, the generator becomes a used oil processor in accordance with R315-15-4.6(a) and shall obtain a used oil processor permit in accordance with R315-15-13.5.

  (4) A generator who self-transports used oil in accordance with R315-15-13.4(f)(1), and who both burns their collected used oil for energy recovery and arranges for permitted use oil transporters to collect that used oil, is deemed to be approved by rule to operate as a used oil transporter and transfer facility for that activity if the following additional conditions are met:

  (i) The self-transported used oil burned for energy recovery is only burned at the generator's central collection facility;

  (ii) The generator registers as a used oil fuel marketer in accordance with R315-15-13.7 and complies with R315-15-7; and

  (iii) The generator arranges for permitted used oil transporters to collect the generator's used oil not burned on site.

  (iv) The self-transported used oil is not stored at the generator's facility longer than 35 days. If the self-transported used oil is stored longer than 35 days, the generator becomes a used oil processor in accordance with R315-15-4.6(a) and shall obtain a used oil processor permit in accordance with R315-15-13.5.

  (g) All used oil transporters and transfer facilities shall obtain and maintain a used oil handler certificates in accordance with R315-15-13.8.

  13.5 USED OIL PROCESSORS/RE-REFINERS

  (a) Applicability. A person may not operate as a used oil processing/re-refining facility without holding a permit issued by the Director.

  (b) General. The application for a permit shall include the following information:

  (1) The name and address of the operator;

  (2) The location of the facility;

  (3) A map of the facility;

  (4) The grades of oil to be produced;

  (5) The methods to be used to determine if used oil received by the transporter or facility is on-specification or off-specification;

  (6) The type of containment and the volume, including type and number of storage vessels to be used and the number and type of transportation vehicles, if applicable;

  (7) The methods of disposing of any waste by-products;

  (8) The status of business, zoning, and other applicable licenses and permits if required by federal, state, and local government entities;

  (9) An emergency spill containment plan, including a list of spill containment equipment to be maintained at the used oil processor facility;

  (10) Proof of liability insurance or other means of financial responsibility for liabilities that may be incurred in processing or rerefining used oil;

  (11) Proof of form and amount of reclamation surety for any facility used in conjunction with transportation or storage of used oil;

  (12) Any other information the Director finds necessary to ensure the safe handling of used oil;

  (13) A closure plan meeting the requirements of R315-15-11.

  (14) A contingency plan meeting the requirements of R315-15-5.3(b);

  (15) Proof of applicant's ownership of the property and facility or, if the property and facility is not owned by the applicant, the owner's written statement acknowledging the activities specified in the application;

  (16) Tank certification in accordance with R315-264-190 through 200 for used oil storage tanks at the processor facility; and

  (17) A facility piping and instrument drawing certified by a Professional Engineer.

  (c) Permit fees. Registration and permitting fees are established under the terms and conditions of Department fee schedule 63J-1-504. A copy of the Division's Fee Schedule is available upon request. Payment of appropriate fees is required prior to issuance of permit approvals and annual used oil handler certificates.

  (d) Annual Reporting. Each used oil processing or rerefining facility shall submit an annual report to the Director of its activities during the calendar year. The annual report shall be submitted to the Director no later than March 1 of the year following the reported activities. The annual report shall either be submitted on a form provided by the Director or shall contain the following information:

  (1) the EPA identification number, name, and address of the processor/re-refiner facility;

  (2) the calendar year covered by the report;

  (3) the quantities of used oil accepted for processing/rerefining and the manner in which the used oil is processed/rerefined, including the specific processes employed;

  (4) the average daily quantities of used oil processed at the beginning and end of the reporting period;

  (5) an itemization of the total amounts of used oil processed or rerefined during the reporting period year specifying the type and amounts of products produced, i.e., lubricating oil, fuel oil, etc.; and

  (6) the amounts of used oil prepared for reuse as a lubricating oil, as a fuel, and for other uses, specifying each type of use, the amounts of used oil consumed or used in the process of preparing used oil for reuse, specifying the amounts and types of waste by-products generated including waste, water, and the methods and specific locations utilized for disposal.

  (e) Changes in information. The owner or operator of the facility shall notify the Director in writing of any changes in the information submitted to apply for a permit within 20 days of the change.

  (f) Used oil processors and re-refiners shall obtain and maintain a current used oil handler certificate in accordance with R315-15-13.8.

  13.6 USED OIL BURNERS

  (a) On-specification used oil fuel burners. Facilities burning only on-specification used oil fuel are not required to register as used oil burners with the Director for the purpose of R315-15-13.6, if they hold a valid air quality operating order or are exempt under R315-15-2.4.

  (b) Off-specification used oil fuel burners

  (1) Applicability. The permitting requirements of this section apply to used oil burners who burn off-specification used oil for energy recovery except as specified in R315-15-6.1(a)(1) through (3). A person may not burn off-specification used oil fuel for energy recovery without holding a permit issued by the Director.

  (2) Permit application. The application for a permit shall include the following information regarding the facility:

  (i) The name and address of the operator;

  (ii) The location of the facility;

  (iii) The type of containment and type and capacity of storage;

  (iv) The type of burner to be used;

  (v) The methods of disposing of any waste by-products;

  (vi) The status of business, zoning, and other applicable licenses and permits required by federal, state, and local governmental entities;

  (vii) An emergency spill containment plan; including a list of spill containment equipment to be maintained at the used oil processor facility.

  (viii) Proof of insurance or other means of financial responsibility for liabilities that may be incurred in storing and burning off-specification used oil fuels.

  (ix) Proof of form and amount of reclamation surety for any facility receiving and burning off-specification used oil.

  (x) A closure plan meeting the requirements of R315-15-11;

  (xi) Proof of applicant's ownership of the property and facility or, if the property and facility is not owned by the applicant, the owner's written statement acknowledging the activities specified in the application;

  (xii) Tank certification in accordance with R315-264-190 through 200 for used oil storage tanks at the processor facility; and

  (xiii) A facility piping and instrument drawing certified by a Professional Engineer.

  (3) Permit fees. Registration and permitting fees are established under the terms and conditions of Utah Code Annotated 63J-1-504. A copy of the Division's Fee Schedule is available upon request. Payment of appropriate fees is required prior to issuance of permit approvals and annual used oil handler certificates.

  (4) Changes in information. The owner or operator of the facility shall notify the Director in writing of any changes in the information submitted during permit application within 20 days of the change.

  (5) Permits by rule. Any facility permitted by rule is not required to obtain a permit as required by R315-15-13.6(b)(1), but may be required to follow operational practices, as determined by the Director, to minimize risk to human health or the environment. A permit by rule is conditional upon continued compliance with the requirements of R315-15-13.6(b), as determined by the Director. Notwithstanding any other provisions of R315-15-13.6, a hazardous waste incinerator facility that has been issued a final permit under R315-270-1, and that implements the requirements of R315-264-340 through 351, shall be deemed to have an approved off-specification used oil burner permit if that facility meets all of the following conditions:

  (i) It burns off-specification used oil only in devices specified in R315-15-6.2(a);

  (ii) It stores used oil in the manner described in R315-15-6.5;

  (iii) It tracks off-specification used oil shipments as described in R315-15-6.6;

  (iv) It complies with R315-15-6.3 and R315-15-6.7;

  (v) It modifies its closure plan required under R315-264-110 through 120 (Closure and Post Closure), to include used oil storage and burning devices, taking into account any used oil activities at this facility;

  (vi) It modifies its financial mechanism or mechanisms required R315-264-140 Through 151 (Financial Requirements), using a mechanism other than a corporate financial test/corporate written guarantee, to reflect the used oil activities at the facility; and

  (vii) It submits to the Director the information required by R315-15-13.6(b)(2)(i) through (vi), and a one-time declaration that the facility intends to burn off-specification used oil.

  (6) Annual Reporting. Each off-specification used oil burner, including those permitted by rule under R315-15-13.6(b)(5), shall submit an annual report to the Director of their activities during the calendar year. The annual report shall be submitted to the Director no later than March 1, of the year following the reported activities. The annual report shall either be submitted on a form provided by the Director or shall contain the following information:

  (i) The EPA identification number, name, and address of the burner facility;

  (ii) The calendar year covered by the report; and

  (iii) The total amount of used oil burned.

  (c) Off-specification used oil burners shall obtain and maintain a current used oil handler certificate in accordance with R315-15-13.8.

  13.7 USED OIL FUEL MARKETERS

  (a) Applicability. A person may not act as a used oil fuel marketer, as defined in R315-15-7, without holding a registration number issued by the Director.

  (b) General. The application for a registration number shall include the following information regarding the facility acting as a used oil fuel marketer:

  (1) The name and address of the marketer.

  (2) The location of any facilities used by the marketer to collect, transport, process, or store used oil subject to separate permits, or registrations under this section.

  (3) The status of business, zoning, and other applicable licenses and permits required by federal, state, and local governmental entities, including registrations or permits required under this part to collect, process/re-refine, transport, or store used oil.

  (4) Sampling and Analysis Plan. Marketers shall develop and follow a written analysis plan describing the procedures that will be used to comply with the analysis requirements of R315-15, including the applicable portions of R315-15-1.2, R315-15-5.4, R315-15-7.3, and R315-15-18. The owner or operator shall keep the plan at the facility. The plan shall address at a minimum the following:

  (i) Specification used oil fuel. The analysis plan shall describe how the marketer will comply with R315-15-1.2, R315-15-5.6, and R315-15-7.3, as applicable.

  (ii) Analytical methods. The plan shall specify the preparation and analytical methods for each parameter.

  (iii) PCBs. The analysis plan shall describe how the marketer will comply with R315-15-18.

  (iv) Generator knowledge. The plan shall describe the requirements for generator knowledge, if applicable.

  (v) Sample Quality Control. The plan shall specify the quality control parameters and acceptance limits.

  (vi) Rebuttable presumption for used oil. The analysis plan shall describe how the marketer will comply with R315-15-1.1(b)(ii) and R315-15-5.4, if applicable.

  (vii) Sampling. The analysis plan shall describe the sampling protocol used to obtain representative samples, including:

  (A) Sampling methods. The marketer shall use one of the sampling methods in R315-261 Appendix I, or a method shown to be equivalent under R315-260-21.

  (B) Sample frequency. The plan shall specify the frequency of sampling to be performed, and whether the analysis will be performed on site or off site.

  (c) Registration fees. Registration and permitting fees are established under the terms and conditions of Utah Code Annotated 63J-1-504. A copy of the Division's Fee Schedule is available upon request. Payment of appropriate fees is required prior to issuance of registration numbers and annual used oil handler certificates.

  (d) A person who acts as used oil fuel marketer shall annually obtain a used oil handler certificate in accordance with R315-15-13.8. A used oil fuel marketer shall not operate without a used oil handler certificate.

  (e) Changes in information. The owner or operator of the facility shall notify the Director in writing of any changes in the information submitted to apply for a registration within 20 days of the change.

  13.8 USED OIL HANDLER CERTIFICATES

  (a) Applicability. As well as obtaining permits and registration described in R315-15-13.4 through 13.7, a person shall not act as a used oil transporter, operator of a transfer facility, processor/re-refiner, off-specification burner, or marketer without applying for, receiving, and maintaining a current used oil handler certificate issued by the Director for each applicable activity. Each used oil permit and marketer registration described in R315-15-13.4 through 13.7 above requires a separate used oil handler certificate.

  (b) General. Each application for a used oil handler certificate shall include the following information:

  (1) business name;

  (2) address to include:

  (i) mailing address; and

  (ii) site address if different from mailing address

  (3) telephone number

  (4) name of business owner;

  (5) name of business operator;

  (6) permit/registration number; and

  (7) type of permit/registration number (i.e., processor, transporter, transfer facility, off-specification burner, or marketer).

  (c) Changes in information. A used oil handler certificate holder shall notify the Director of any changes in the information provided in Subsection R315-15-13.8(b) within 20 days of implementation of the change.

  (d) A used oil handler certificate will be issued to an applicant following the:

  (1) completion and approval of the application required by R315-15-13.8(a); and

  (2) payment of the fee required by the Annual Appropriations Act.

  (e) A used oil handler certificate is not transferable and shall be valid January 1 through December 31 of the year issued. The certificate shall become void if the permit or registration associated with the used oil activity described in the certificate, in accordance with R315-15-13.8(b)(6) in the application, is revoked under R315-15-15.2 or if the Director, upon the written request of the permittee or registration holder, cancels the certificate.

  (f) The certificate registration fee shall be paid prior to operation within any calendar year.


R315-15-14. DIYer Reimbursement
Latest version.

  14.1 DIYER USED OIL COLLECTION CENTER INCENTIVE PAYMENT APPLICABILITY

  (a) The Director shall pay a semi-annual recycling fee incentive to registered DIYer used oil collection centers and curbside programs approved by the Director for each gallon of used oil collected from DIYer used oil generators, and transported by a permitted used oil transporter to a permitted used oil processor/re-refiner, burner, registered marketer or burned in accordance with R315-15-2.4(b).

  (b) All registered DIYer used oil collection centers can qualify for a recycling incentive payment of up to $0.25 per gallon, subject to availability of funds and the priorities of Utah Code Annotated 19-6-720.

  14.2 REIMBURSEMENT PROCEDURES

  In order for DIYer collection centers to qualify for the recycling incentive payment they are required to comply with the following procedures.

  (a) Submit a copy of all records of DIYer and farmer, as defined in R315-15-2.1(a)(4), used oil collected during the semi-annual collection periods of January through June and July through December for which the reimbursement is requested. These records shall be submitted within 30 days following the end of the semi-annual collection period.

  (b) Reimbursements will be issued by the Director within 30 days following the report filing period.

  (c) Reports received later than 60 days after the end of the semi-annual collection period for which reimbursement is requested will be paid during the next reimbursement period.

  (d) Any reimbursement requests outside the timeframe outlined in R315-15-14.2(a) will not be granted unless approved by the Director.


R315-15-15. Issuance, Renewal, and Revocation of Permits and Registrations
Latest version.

  15.1 PUBLIC COMMENTS AND HEARING.

  (a) The Director shall:

  (1) determine if the permit application or modification request is complete and meets all requirements of R315-15-13;

  (2) publish notice of the proposed permit in a newspaper of general circulation in the state and also in a newspaper of general circulation in the county in which the proposed permitted facility is located;

  (3) provide a 15-day public comment period from the date of publication to allow the public time to submit written comments;

  (4) consider submitted public comments received within the comment period; and

  (5) send a written decision to the applicant and to persons submitting comments,

  (b) The Director's decision under R315-15-15.1(a) may be appealed in accordance with Utah Administrative Code R305-7.

  (c) Duration of Permits. Used oil permits shall be effective for a fixed term not to exceed ten years. Any Permittee holding a permit issued on or before January 1, 2005 who wants to continue operating shall submit an application for a new permit not later than 180 days after January 1, 2015. The term of a permit shall not be extended by modification to the permit.

  (d) The conditions of an expired permit continue in force until the effective date of a new permit if:

  (1) The permittee has submitted a timely application under R315-15-13, at least 180 days prior to the expiration date of the current permit. The permit application shall contain all the materials required by R315-15-13.

  (2) The Director, through no fault of the permittee, does not issue a new permit with an effective date on or before the expiration date of the previous permit (for example, when issuance is impracticable due to time or resource constraints).

  (e) Effect. Permits continued under this section remain fully effective and enforceable.

  (f) Enforcement. When the permittee is not in compliance with the conditions of the expiring or expired permit, the Director may choose to do any or all of the following;

  (1) Initiate enforcement action based upon the permit that has been continued;

  (2) Issue a notice of intent to deny the new permit under R315-15-15.2. If the permit is denied, the owner or operator is required to cease the activities authorized by the continued permit or be subject to enforcement action for operating without a permit;

  (3) Issue a new permit under R315-15-15.2 with appropriate conditions;

  (4) Take other actions authorized by these rules

  (g) Five-Year Review of Permit. Each used oil permit, including the costs of closure and post closure care issued under R315-15-13, shall be reviewed by the Director five years after the permit's issuance, or when the Director determines that a permit requires review and modification.

  15.2 MODIFICATION AND REVOCATION OF PERMITS, REGISTRATIONS AND HANDLER CERTIFICATES.

  (a) A permit may be considered for modification, renewal, or termination at the request of any interested person, including the permittee, or upon the Director's initiative as a result of new information or changes in statues or rules. Requests for modification, reissuance, or termination shall be submitted in writing to the Director and shall contain facts or reasons supporting the request. The permit modification requests shall not be implemented until approval of the Director.

  Violation of any permit or registration conditions or failure to comply with any provisions of the applicable statutes and rules, shall be grounds for imposing statutory sanctions, including denial of an application for permit, registration, or used oil handler certificate.

  (b) Request for agency action. The owner or operator of a facility may contest an order associated with modification, renewal, or termination in accordance with Utah Administrative Code R305-7.


R315-15-16. Grants
Latest version.

  16.1 STATUTORY AUTHORITY.

  Utah Code Annotated 19-6-720 authorizes the Division of Waste Management and Radiation Control to award grants, as funds are available, for the following:

  (a) Used oil collection centers;

  (b) Used oil collection events;

  (c) Curbside used oil collection programs, including costs of retrofitting trucks, curbside containers, and other costs of collection programs; and

  (d) Public education programs and outreach.

  16.2 ELIGIBILITY AND APPLICATION.

  (a) The establishment of new or the enhancement of existing used oil collection centers or curbside collection programs that address the proper management of used lubricating oil may be eligible for grant assistance.

  (b) A Used Oil Recycling Block Grant Application Package, made available by the Director, shall be completed and submitted to the Director for consideration.

  16.3 LIMITATIONS.

  (a) The grantee shall commit to perform the permitted used oil handling activity for a minimum of two years.

  (b) If the two-year commitment is not fulfilled, the grantee may be required to repay all or a portion of the grant amount.

  16.4 USED OIL TRANSPORTATION COSTS FROM USED OIL COLLECTION CENTERS

  (a) Grant funds may be used for costs for a permitted used oil transporter to collect and transport used oil from a used oil collection center (UOCC) located within a rural area that meets the following criteria:

  (1) accepts only:

  (i) DIYER used oil, Type A UOCC; or

  (ii) both DIYER and farmer used oil, Type B UOCC

  (2) is located in a Class 4 municipality, as described in Section 10-2-301, or in an area with a population less than that of a Class 4 municipality;

  (3) stays active with the Used Oil Program for at least two years after receiving the grant or the grant funds shall be reimbursed;

  (4) completes a grant application that is signed by the owner of the collection center; and

  (5) obtains a minimum of one transportation bid from a permitted used oil transporter in accordance with Section R33-5-104.

  (b) Grant funds may be used for costs for a permitted used oil transporter to collect and transport used oil from a Type C Used Oil Collection Center if the UOCC meets the following criteria:

  (1) Is a Utah municipal landfill that is registered as a Type C used oil collection center with the Division of Waste Management and Radiation Control;

  (2) Only allows small businesses that qualify as a Very Small Quantity Generator (VSQGs) of hazardous waste, to deliver used oil in a volume of less than 55 gallons per visit per day; and

  (3) One transportation bid from a permitted used oil transporter is submitted for requests less than $1,000.00, or three bids if over $1,000.00.

  (c) Grant funds may be considered for costs for a permitted used oil transporter to collect and transport used oil from a Used Oil Collection Center that does not meet the criteria outlined in Subsections R315-15-16.4(a) or (b)on a case-by-case basis.

  16.5 FUNDING

  (a) An applicant is not required to provide matching funds.

  (b) The Director may withhold 10 percent of the funds from a grant recipient until the grant is completed and the final documentation submitted.

  (c) The Director may approve a request for advance payment based upon justification offered by the applicant.

  (d) A grant application shall include all bids for expenses to be paid by the grant in accordance with Rule R33-5.

  16.6 APPLICATION CONTENTS

  (a) A grant application form is part of the grant application package available from the Director and consists of the following sections:

  (1) Applicant Information. The applicant shall include basic information regarding the applicant and the individual or entity responsible for the project implementation.

  (2) Used Oil Project Request for Funding. The project funding request shall include the following:

  (i) Background. The background information shall include a description of:

  (A) The absence or existence of used oil collection opportunities in the area to be served by the used oil project; and

  (B) The population of the proposed project area.

  (ii) Project Description and Goals; and

  (iii) Funding Sources.

  (3) Project Budget. The project budget may include a cost breakdown of the following categories:

  (i) Used oil transportation and disposal expenses.

  (ii) Contractor or consultant expenses.

  (iii) Construction expenses.

  (iv) Equipment.

  (v) Materials and supplies.

  (vi) Public education and outreach.

  (4) Eligibility summary. The applicant shall include, as applicable, the following information for each:

  (i) Used oil collection center:

  (A) Name of the facility;

  (B) Physical address; and

  (C) Phone number; and

  (ii) Curbside collection program:

  (A) Name, address, and phone number of the program operator;

  (B) Number of residents served by the program; and

  (C) Collection schedule

  (5) Certification Statement and Signature.

  16.7 APPLICATION SUBMISSION

  Applicants shall submit an original application using the application package of Subsection R315-15-16.2(b) to the Director.

  16.8 AUDIT REQUIREMENTS

  (a) A grant may be subject to a desk or field audit.

  (b) The grantee is responsible for maintaining source documents substantiating the expenditures claimed and shall make them available at the time of an audit.

  (c) Records relating to the implemented program may include:

  (1) Expenditure ledger;

  (2) Paid warrants;

  (3) Contracts;

  (4) Change orders;

  (5) Invoices; and

  (6) Cancelled checks.

  (d) Records shall be maintained for a period of three years from the date of final payment by the State.

  16.9 ADMINISTRATIVE PROCEDURES

  (a) A grantee shall submit a final report within one month of completion of the project or by a later date specified by the Director. The report shall include the following information:

  (1) A description of the completed used oil collection program, including any amendments;

  (2) The estimated number of participants in the program;

  (3) A description of the program's public education efforts;

  (4) A description of measures taken to continue the program; and

  (5) A complete and final itemization of how grant funds were expended.

  16.10 FAILURE TO COMPLY

  Failure to comply with the agreement requirements may result in the Director terminating, suspending, or requiring the grantee to repay some or all of the grant.

  16.11 GRANT PAYMENTS

  (a) General Requirements.

  (1) The Director shall reimburse the grantee for performing only those services as specified in the grant application. Any deviations from the use of funds specified in the application shall be approved by the Director before an expenditure for that item is made.

  (2) Payment shall be made to the grantee only. It shall be the responsibility of the grantee to pay all contractors and subcontractors for purchased goods and services.

  (3) The Director may withhold and retain ten percent of the grant award until the grant is completed and the final documentation submitted.

  (4) Requests for advance payment shall be submitted in writing to the Director and demonstrate that the grantee will incur a specific expenditure(s) prior to or shortly after payment for the State. Suggested documentation includes:

  (i) Purchase orders; and

  (ii) Invoices.

  (5) The Director may partially or fully deny advance payment requests.

  (b) Submittal of payment requests.

  (1) All payment requests shall be submitted using the completed Payment Request Form of the grant application package of Subsection R315-15-16.2(b) and signed by the individual authorized in the grant application.

  (2) Payment requests shall include an itemization of all expenses by budget expense type.

  (3) Payment requests shall include copies of documents supporting the claimed expenses, such as bids, receipts, canceled checks, and sole source justifications. Supporting documents shall contain sufficient information to establish purchases made or costs incurred. At a minimum, the documentation should include the name, amount, and date of purchase for the expense.

  (4) All payment requests shall be submitted to the Director.

  16.12 RELEASE OF FUNDS

  (a) The Director shall review and approve all payment requests before payment is made. The grantee shall meet the following conditions before the Director shall process a payment request during the project term:

  (1) The grantee has submitted any required project reports and the Director has deemed them to be satisfactory;

  (2) The Director has received copies of applicable contracts and/or subcontracts; and

  (3) The grantee has received applicable permits or permit waivers from governmental agencies and the Director has received copies of such documentation.

  (b) After Director approval, payment requests shall be forwarded to the Division of Finance for issuance of pay warrants.

  (c) If ten percent of the total grant was previously withheld, the Director shall release the remaining ten percent upon receipt and acceptance of the final report and final payment request.

  16.13 GRANT CLOSEOUT

  (a) The Director shall close out the grant when it is determined that all applicable administrative actions and all required work of the grant have been completed.

  (b) Upon receipt of the final report, the Director shall ensure all work has been completed and all unexpended funds are refunded to the State.

  (c) The grantee's obligations under the Terms and Conditions of the grant application package of Subsection R315-15-16.2(b) shall be deemed discharged only upon acceptance of the final report by the Director.

  (d) The grantee shall retain all financial and project records, supporting documents, statistical records and other records of projects funded by this program. The Director, or his authorized representative, shall have access to all related records during progress of the project and for at least three years after completion.


R315-15-17. Wording of Financial Assurance Mechanisms
Latest version.

  17.1 APPLICABILITY

  R315-15-17 presents the standard wording forms to be used for the financial assurance mechanisms found in R315-15-12. The following forms are hereby incorporated by reference and are available at the Division of Waste Management and Radiation Control located at 195 North 1950 West, Salt Lake City, Utah, during normal business hours or on the Division's web site, http://www.hazardouswaste.utah.gov/.

  (a) The Division requires that the forms described in R315-15-17.2 through R315-15-17.14 shall be used for all financial assurance filings and shall be signed original documents. The wording of the forms shall be identical to the wording specified in R315-15-17.2 through R315-15-17.14.

  (b) The Director may substitute new wording for the wording found in any of the financial assurance mechanism forms when such language changes are necessary to conform to applicable financial industry changes, when industry-wide consensus language changes are submitted to the Director.

  17.2 TRUST AGREEMENTS

  The trust agreement for a trust fund must be worded as found in the Trust Agreement Form approved by the Director.

  17.3 SURETY BOND GUARANTEEING PAYMENT INTO A STANDBY TRUST AGREEMENT TRUST FUND

  The surety bond guaranteeing payment into a standby trust agreement trust fund must be worded as found in the Surety Bond Guaranteeing Payment into a Standby Trust Agreement Trust Fund Form approved by the Director.

  17.4 IRREVOCABLE STANDBY LETTER OF CREDIT WITH STANDBY TRUST AGREEMENT

  The letter of credit must be worded as found in the Irrevocable Standby Letter of Credit with Standby Trust Agreement Form approved by the Director.

  17.5 UTAH USED OIL POLLUTION LIABILITY INSURANCE ENDORSEMENT FOR CLEANUP AND CLOSURE

  The insurance endorsement of cleanup and closure must be worded as found in the Utah Used Oil Pollution Liability Insurance Endorsement for Cleanup and Closure Form approved by the Director.

  17.6 UTAH USED OIL TRANSPORTER POLLUTION LIABILITY ENDORSEMENT FOR SUDDEN OCCURRENCE

  The used oil transporter pollution liability endorsement for sudden occurrence must be worded as found in the Utah Used Oil Transporter Pollution Liability Endorsement for Sudden Occurrence Form approved by the Director.

  17.7 UTAH USED OIL POLLUTION LIABILITY ENDORSEMENT FOR SUDDEN OCCURRENCE

  The used oil pollution liability endorsement for sudden occurrence for permitted facilities other than permitted transporters must be worded as found in the Utah Used Oil Pollution Liability Endorsement for Sudden Occurrence Form approved by the Director.

  17.8 UTAH USED OIL POLLUTION LIABILITY ENDORSEMENT FOR NON-SUDDEN OCCURRENCE

  The used oil pollution liability endorsement for non-sudden occurrence must be worded as found in the Utah Used Oil Pollution Liability Endorsement Non-Sudden Occurrence Form approved by the Director.

  17.9 UTAH USED OIL POLLUTION LIABILITY ENDORSEMENT FOR COMBINED SUDDEN AND NON-SUDDEN OCCURRENCES

  The used oil pollution liability endorsement combined for sudden and non-sudden occurrence must be worded as found in the Utah Used Oil Pollution Liability Endorsement for Combined Sudden and Non-Sudden Occurrences Form approved by the Director.

  17.10 LETTER OF CREDIT FOR THIRD-PARTY DAMAGES FROM ENVIRONMENTAL POLLUTION LIABILITY WITH OPTIONAL STANDBY TRUST AGREEMENT TO BE USED BY TRANSFER/PROCESSOR/RE-REFINER/OFF-SPECIFICATION BURNER FACILITY

  The letter of credit must be worded as found in the Letter of Credit for Third Party Damages from Environmental Pollution Liability with Optional Standby Trust Agreement to be used by Transfer/Processor/Re-refiner/Off-specification Burner Facility Form approved by the Director.

  17.11 PAYMENT BOND FOR THIRD-PARTY DAMAGES FROM ENVIRONMENTAL POLLUTION LIABILITY TO BE USED BY TRANSFER/PROCESSOR/RE-REFINER/OFF-SPECIFICATION BURNER FACILITY

  A surety bond must be worded as found in the Payment Bond for Third Party Damages from Environmental Pollution Liability to be used by Transfer/Processor/Re-refiner/Off-specification burner Facility Form approved by the Director.

  17.12 TRUST AGREEMENT FOR THIRD-PARTY DAMAGES FROM ENVIRONMENTAL POLLUTION LIABILITY TO BE USED BY TRANSFER/PROCESSOR/RE-REFINER/OFF-SPECIFICATION BURNER FACILITY

  A trust agreement must be worded as found in the Trust Agreement for Third Party Damages from Environmental Pollution Liability to be used by Transfer/Processor/Re-refiner/Off-specification Burner Facility Form approved by the Director.

  17.13 STANDBY TRUST AGREEMENT ASSOCIATED WITH THIRD-PARTY DAMAGES FROM ENVIRONMENTAL POLLUTION LIABILITY REQUIRING A STANDBY TRUST AGREEMENT TO BE USED BY TRANSFER/PROCESSOR/RE-REFINER/OFF-SPECIFICATION BURNER FACILITY

  A standby trust agreement must be worded as found in the Standby Trust Agreement Associated with Third Party Damages from Environmental Pollution Liability Requiring Standby Trust Agreement to be used by Transfer/Processor/Re-refiner/Off-specification Burner Facility Form approved by the Director.

  17.14 STANDBY TRUST AGREEMENT, OTHER THAN LIABILITY, FOR TRANSFER/PROCESSOR/RE-REFINER/OFF-SPECIFICATION BURNER FACILITY

  The standby trust agreement for a trust fund must be worded as found in the Standby Trust Agreement, other than Liability for Transfer/Processor/Re-refiner/Off-specification Burner Facility Form approved by the Director.


R315-15-18. Polychlorinated Biphenyls (PCBs)
Latest version.

  (a) Used oil containing polychlorinated biphenyl (PCB) concentrations of 50 ppm and above is subject to TSCA regulations in 40 CFR 761. Used oil containing PCB concentrations greater than or equal to 2 ppm but less than 50 ppm is subject to both R315-15 and 40 CFR 761.

  (b) Used oil transporter PCB testing. Used oil transporters shall determine the PCB content of used oil being transported is less than 50 ppm prior to transferring the oil into the transporter's vehicles. The transporter shall make this determination as follows:

  (1) Used dielectric oil. Dielectric oil used in transformers and other high voltage devices shall be certified to be less than 50 ppm prior to loading to the transporter's vehicle through laboratory testing following the procedures described in R315-15-18(d).

  (2) Other used oils shall be certified to be less than 50 ppm prior to transfer through either:

  (A) Laboratory testing following the procedures described in R315-15-18(d) below, or

  (B) Written certification from the generator that the PCB content of the used oil is less than 50 ppm based on manufacturing specifications and process knowledge.

  (c) Used oil marketer PCB testing. To ensure that used oil destined to be burned for energy recovery is not a regulated waste under the TSCA regulations, used oil fuel marketers shall determine whether the PCB content of used oil being burned for energy recovery is below 2 ppm. A marketer shall make this determination in a manner consistent with the used oil marketer's sampling and analysis plan.

  (d) Laboratory testing for PCBs. Used oil testing for total PCBs shall include the following Aroclors: 1016, 1221, 1232, 1242, 1248, 1254, and 1260. If plasticizers (used in polyvinyl chloride plastic, neoprene, chlorinated rubbers, laminating adhesives, sealants and caulk and joint compounds etc.) are present, then the used oil shall also be analyzed for Aroclors 1262 and 1268. If other Aroclors are known or suspected to be present, then the used oil shall be analyzed for those additional Aroclors.

  (e) The following Utah Certified Laboratory SW-846 methodologies shall be used for PCBs:

  (1) Preparation method 3580A, clean up method 3665A, and analytical method 8082A.

  (2) Individual Aroclors shall be reported with a reporting limit of 1 ppm or less.

  (3) If the source of the PCBs is known to be an Aroclor, and the Aroclor is unlikely to be significantly altered in homologue composition such as weathering, Aroclors listed in R315-15-18(d) shall be reported. Analytical results from all 209 individual congeners or ten homologue groups shall be submitted for any sample that has an altered homologue composition such as weathering unless prior approval is obtained from the Director.