R307-351-5. VOC Content Limits  


Latest version.
  •   (1) No owner or operator shall apply graphic arts materials with a VOC content greater than the amounts specified in Table 1 or Table 2, unless the owner or operator uses an add-on control device as specified in R307-351-6.


    TABLE 1


    VOC Limits

    (values in gram of VOC per liter, minus water and

    exempt solvents (compounds not classified as VOC as defined in

    R307-101-2)


    Graphic Art Material VOC Limit (g/L)


    Adhesive 150

    Coating 300

    Flexographic Fluorescent Ink 300

    Flexographic Ink-Non-Porous Substrate 300

    Flexographic Ink-Porous Substrate 225

    Gravure Ink 300

    Letterpress Ink 300

    Offset Lithographic Ink 300

    Heatset Web Offset Litographic ink 300

    Heatset Web Offset Lithographic Ink:

              Used on Book Presses and Presses

              Less Than 22 Inches in Diameter 400


              Used on Presses With Potential to Emit Less

              Than 10 Tons/Year 400


      (2) No owner or operator shall apply fountain solution, including additives with a VOC content greater than the amounts specified in Table 2, unless the owner or operator uses an add-on control device as specified in R307-351-6.


    TABLE 2


    VOC Limits

    (values in gram of VOC per liter, minus water and

    exempt solvents (compounds not classified as VOC as defined in R307-101-2), as applied


    Graphic Art Material VOC Limit (g/L)


    Heatset Web-Fed

              Alcohol without Refrigerated Chiller 16

              Alcohol with Refrigerated Chiller 30

              Alcohol Substitute 50

    Sheet-Fed

              Alcohol without Refrigerated Chiller 50

              Alcohol with Refrigerated Chiller 85

              Alcohol Substitute 50

    Non-Heatset Web-Fed

              All Alcohol Substitutes 50


      (3) Alcohol containing fountain solutions shall not be used in non-heatset web-fed operations.

      (4) Cleaning materials with a VOC composite vapor pressure of less than 10 mm Hg at 68 degrees Fahrenheit or cleaning materials containing less than 50 percent VOC by weight shall be used.