R313-15-502. Conditions Requiring Individual Monitoring of External and Internal Occupational Dose  


Latest version.
  • Each licensee or registrant shall monitor exposures from sources of radiation at levels sufficient to demonstrate compliance with the occupational dose limits of Rule R313-15. As a minimum:

    (1) Each licensee or registrant shall monitor occupational exposure to radiation from licensed, unlicensed, and registered radiation sources under the control of the licensee and shall supply and require the use of individual monitoring devices by:

    (a) Adults likely to receive, in one year from sources external to the body, a dose in excess of ten percent of the limits in Subsection R313-15-201(1); and

    (b) Minors likely to receive, in one year, from radiation sources external to the body, a deep dose equivalent in excess of one mSv (0.1 rem), a lens dose equivalent in excess of 1.5 mSv (0.15 rem), or a shallow dose equivalent to the skin or to the extremities in excess of five mSv (0.5 rem); and

    (c) Declared pregnant women likely to receive during the entire pregnancy, from radiation sources external to the body, a deep dose equivalent in excess of one mSv (0.1 rem); and

    (d) Individuals entering a high or very high radiation area; and

    (e) Individuals working with medical fluoroscopic equipment.

    (i) An individual monitoring device used for the dose to an embryo/fetus of a declared pregnant woman, pursuant to Subsection R313-15-208(1), shall be located under the protective apron at the waist.

    (A) If an individual monitoring device worn by a declared pregnant woman has a monthly reported dose equivalent value in excess of 0.5 mSv (50 mrem), the value to be used for determining the dose to the embryo/fetus, pursuant to Subsection R313-15-208(3)(a) for radiation from medical fluoroscopy, may be the value reported by the individual monitoring device worn at the waist underneath the protective apron which has been corrected for the potential overestimation of dose recorded by the monitoring device because of the overlying tissue of the pregnant individual. This correction shall be performed by a radiation safety officer of an institutional radiation safety committee, a qualified expert approved by the Director.

    (ii) An individual monitoring device used for lens dose equivalent shall be located at the neck, or an unshielded location closer to the eye, outside the protective apron.

    (iii) When only one individual monitoring device is used to determine the effective dose equivalent for external radiation pursuant to Subsection R313-15-201(3)(b), it shall be located at the neck outside the protective apron. When a second individual monitoring device is used, for the same purpose, it shall be located under the protective apron at the waist. Note: The second individual monitoring device is required for a declared pregnant woman.

    (iv) A registrant is not required to supply and require the use of individual monitoring devices provided the registrant has conducted a survey, pursuant to Section R313-15-501, that demonstrates that the working environment the individual encounters will not likely result in a dose in excess of ten percent of the limits in Subsection R313-15-201(1), and that the individual is neither a minor nor a declared pregnant woman.

    (2) Each licensee or registrant shall monitor, to determine compliance with Section R313-15-204, the occupational intake of radioactive material by and assess the committed effective dose equivalent to:

    (a) Adults likely to receive, in one year, an intake in excess of ten percent of the applicable ALI(s) in Table I, Columns 1 and 2, of Appendix B of 10 CFR 20.1001 to 20.2402, (2010), which is incorporated by reference; and

    (b) Minors likely to receive, in one year, a committed effective dose equivalent in excess of one mSv (0.1 rem); and

    (c) Declared pregnant women likely to receive, during the entire pregnancy, a committed effective dose equivalent in excess of one mSv (0.1 rem).

    Note: All of the occupational doses in Section R313-15-201 continue to be applicable to the declared pregnant worker as long as the embryo/fetus dose limit is not exceeded.