R309-600-6. Definitions  


Latest version.
  • (1) The following terms are defined for the purposes of this rule:

    (a) "Collection area" means the area surrounding a ground-water source which is underlain by collection pipes, tile, tunnels, infiltration boxes, or other ground-water collection devices.

    (b) "Controls" means the codes, ordinances, rules, and regulations currently in effect to regulate a potential contamination source. "Controls" also means physical controls which may prevent contaminants from migrating off of a site and into surface or ground water. "Controls" also means negligible quantities of contaminants.

    (c) "Criteria" means the conceptual standards that form the basis for DWSP area delineation to include distance, ground-water time of travel, aquifer boundaries, and ground-water divides.

    (d) "Criteria threshold" means a value or set of values selected to represent the limits above or below which a given criterion will cease to provide the desired degree of protection.

    (e) "DDW" means Division of Drinking Water.

    (f) "DWSP Program" means the program to protect drinking water source protection zones and management areas from contaminants that may have an adverse effect on the health of persons.

    (g) "DWSP Zone" means the surface and subsurface area surrounding a ground-water source of drinking water supplying a PWS, through which contaminants are reasonably likely to move toward and reach such ground-water source.

    (h) "Designated person" means the person appointed by a PWS to ensure that the requirements of R309-600 are met.

    (i) "Director" means the Director of the Division of Drinking Water.

    (j) "Engineer" means a person licensed under the Professional Engineers and Land Surveyors Licensing Act, 58-22 of the Utah Code, as a "professional engineer" as defined therein.

    (k) "Existing ground-water source of drinking water" means a public supply ground-water source for which plans and specifications were submitted to DDW on or before July 26, 1993.

    (l) "Geologist" means a person licensed under the Professional Geologist Licensing Act, 58-76 of the Utah Code, as a "professional geologist" as defined therein.

    (m) "Ground-water Source" means any well, spring, tunnel, adit, or other underground opening from or through which ground-water flows or is pumped from subsurface water-bearing formations.

    (n) "Hydrogeologic methods" means the techniques used to translate selected criteria and criteria thresholds into mappable delineation boundaries. These methods include, but are not limited to, arbitrary fixed radii, analytical calculations and models, hydrogeologic mapping, and numerical flow models.

    (o) "Land management strategies" means zoning and non-zoning strategies which include, but are not limited to, the following: zoning and subdivision ordinances, site plan reviews, design and operating standards, source prohibitions, purchase of property and development rights, public education programs, ground-water monitoring, household hazardous waste collection programs, water conservation programs, memoranda of understanding, written contracts and agreements, and so forth.

    (p) "Land use agreement" means a written agreement wherein the owner(s) agrees not to locate or allow the location of uncontrolled potential contamination sources or pollution sources within zone one of new wells in protected aquifers. The owner(s) must also agree not to locate or allow the location of pollution sources within zone two of new wells in unprotected aquifers and new springs unless the pollution source agrees to install design standards which prevent contaminated discharges to ground water. This restriction must be binding on all heirs, successors, and assigns. Land use agreements must be recorded with the property description in the local county recorder's office. Refer to R309-600-13(2)(d).

    Land use agreements for protection areas on publicly owned lands need not be recorded in the local county recorder office. However, a letter must be obtained from the Administrator of the land in question and meet the requirements described above.

    (q) "Management area" means the area outside of zone one and within a two-mile radius where the Optional Two-mile Radius Delineation Procedure has been used to identify a protection area.

    For wells, land may be excluded from the DWSP management area at locations where it is more than 100 feet lower in elevation than the total drilled depth of the well.

    For springs and tunnels, the DWSP management area is all land at elevation equal to or higher than, and within a two-mile radius, of the spring or tunnel collection area. The DWSP management area also includes all land lower in elevation than, and within 100 horizontal feet, of the spring or tunnel collection area. The elevation datum to be used is the point of water collection. Land may also be excluded from the DWSP management area at locations where it is separated from the ground-water source by a surface drainage which is lower in elevation than the spring or tunnel collection area.

    (r) "New ground-water source of drinking water" means a public supply ground-water source of drinking water for which plans and specifications are submitted to DDW after July 26, 1993.

    (s) "Nonpoint source" means any diffuse source of pollutants or contaminants not otherwise defined as a point source.

    (t) "PWS" means public water system.

    (u) "Point source" means any discernible, confined, and discrete source of pollutants or contaminants, including but not limited to any site, pipe, ditch, channel, tunnel, conduit, well, discrete fissure, container, rolling stock, animal feeding operation with more than ten animal units, landfill, or vessel or other floating craft, from which pollutants are or may be discharged.

    (v) "Pollution source" means point source discharges of contaminants to ground water or potential discharges of the liquid forms of "extremely hazardous substances" which are stored in containers in excess of "applicable threshold planning quantities" as specified in SARA Title III. Examples of possible pollution sources include, but are not limited to, the following: storage facilities that store the liquid forms of extremely hazardous substances, septic tanks, drain fields, class V underground injection wells, landfills, open dumps, landfilling of sludge and septage, manure piles, salt piles, pit privies, drain lines, and animal feeding operations with more than ten animal units.

    The following definitions are part of R309-600 and clarify the meaning of "pollution source:"

    (i) "Animal feeding operation" means a lot or facility where the following conditions are met: animals have been or will be stabled or confined and fed or maintained for a total of 45 days or more in any 12 month period, and crops, vegetation forage growth, or post-harvest residues are not sustained in the normal growing season over any portion of the lot or facility. Two or more animal feeding operations under common ownership are considered to be a single feeding operation if they adjoin each other, if they use a common area, or if they use a common system for the disposal of wastes.

    (ii) "Animal unit" means a unit of measurement for any animal feeding operation calculated by adding the following numbers; the number of slaughter and feeder cattle multiplied by 1.0, plus the number of mature dairy cattle multiplied by 1.4, plus the number of swine weighing over 55 pounds multiplied by 0.4, plus the number of sheep multiplied by 0.1, plus the number of horses multiplied by 2.0.

    (iii) "Extremely hazardous substances" means those substances which are identified in the Sec. 302(EHS) column of the "Title III List of Lists: Consolidated List of Chemicals Subject to the Emergency Planning and Community Right-to-Know Act (EPCRA) and Section 112(R) of the Clean Air Act, As Amended," (550B98017). A copy of this document may be obtained from: NCEPI, PO Box 42419, Cincinnati, OH 45202. Online ordering is also available at http://www.epa.gov/ncepihom/orderpub.html.

    (w) "Potential contamination source" means any facility or site which employs an activity or procedure which may potentially contaminate ground water. A pollution source is also a potential contamination source.

    (x) "Protected aquifer" means a producing aquifer in which the following conditions are met:

    (i) A naturally protective layer of clay, at least 30 feet in thickness, is present above the aquifer;

    (ii) the PWS provides data to indicate the lateral continuity of the clay layer to the extent of zone two; and

    (iii) the public-supply well is grouted with a grout seal that extends from the ground surface down to at least 100 feet below the surface, and for a thickness of at least 30 feet through the protective clay layer.

    (y) "Replacement well" means a public-supply well drilled for the sole purpose of replacing an existing public-supply well which is impaired or made useless by structural difficulties and in which the following conditions are met:

    (i) the proposed well location shall be within a radius of 150 feet from an existing ground-water supply well, as defined in R309-600-6(1)(k); and

    (ii) the PWS provides a copy of the replacement application approved by the State Engineer (refer to Section 73-3-28 of the Utah Code Annotated).

    (z) "Time of travel" means the time required for a particle of water to move in the producing aquifer from a specific point to a ground-water source of drinking water.

    (aa) "Unprotected aquifer" means any aquifer that does not meet the definition of a protected aquifer.

    (bb) "Wellhead" means the physical structure, facility, or device at the land surface from or through which ground-water flows or is pumped from subsurface, water-bearing formations.