Utah Administrative Code (Current through November 1, 2019) |
R307. Environmental Quality, Air Quality |
R307-502. Oil and Gas Industry: Pneumatic Controllers |
R307-502-1. Purpose |
Latest version.
|
(1) The purpose of R307-502 is to reduce emissions of volatile organic compounds from pneumatic controllers that are associated with oil and gas operations. (2) The rule requires existing pneumatic controllers to meet the standards established for new controllers in 40 CFR Part 60, Subpart OOOO. |
R307-502-2. Definitions |
Latest version.
|
(1) The definitions in 40 CFR 60, Subpart OOOO Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution, which is incorporated by reference in R307-210 apply to R307-502. (2) "Existing pneumatic controller" means a pneumatic controller affected facility as described in 40 CFR 60.5365(d)(1) through (3) that was constructed, modified, or reconstructed prior to October 15, 2013. |
R307-502-3. Applicability |
Latest version.
|
R307-502 applies to the owner or operator of any existing pneumatic controller in Utah. |
R307-502-4. Retrofit Requirements |
Latest version.
|
(1) Effective December 1, 2015, all existing pneumatic controllers in Duchesne County or Uintah County shall meet the standards established for pneumatic controller affected facilities that are constructed, modified or reconstructed on or after October 15, 2013, as specified in 40 CFR 60, Subpart OOOO Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution. (2) Effective April 1, 2017 all existing pneumatic controllers in Utah shall meet the standards established for pneumatic controller affected facilities that are constructed, modified or reconstructed on or after October 15, 2013 as specified in 40 CFR 60, Subpart OOOO Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution. |
R307-502-5. Documentation Required |
Latest version.
|
(1) The tagging requirements in 40 CFR 60.5390(b)(2) and 40 CFR 60.5390(c)(2), incorporated by reference in R307-210, are modified to not require the month and year of installation, reconstruction or modification for existing pneumatic controllers. (2) The recordkeeping requirements in 40 CFR 60.5420(c)(4)(i), incorporated by reference in R307-210, are modified to not require records of the date of installation or manufacturer specifications for existing pneumatic controllers. |