Utah Administrative Code (Current through November 1, 2019) |
R307. Environmental Quality, Air Quality |
R307-361. Architectural Coatings |
R307-361-5. Standards
-
(1) Except as provided in R307-361-4, no person shall manufacture, blend, or repackage, supply, sell, or offer for sale within the counties in R307-361-2; or solicit for application or apply within those counties any architectural coating with a VOC content in excess of the corresponding limit specified in Table 1.
TABLE 1
VOC Content Limit for Architectural and Industrial Maintenance
Coatings
(Limits are expressed as VOC content, thinned to the
manufacturer's maximum thinning recommendation, excluding any
colorant added to tint bases.)
COATING CATEGORY VOC Content Limit
(grams/liter)
Flat coatings 50
Non-flat coatings 100
Non-flat/high-gloss coatings 150
Specialty Coatings
Aluminum roofing 450
Basement Specialty Coatings 400
Bituminous Specialty Coatings 400
Bituminous roof coatings 270
Bituminous roof primers 350
Bond beakers 350
Calcimine recoaters 475
Concrete curing compounds 350
Concrete/masonary sealer 100
Concrete surface retarders 780
Conjugated oil varnish 450
Conversion varnish 725
Driveway sealers 50
Dry fog coatings 150
Faux finishing coatings 350
Fire resistive coatings 350
Floor coatings 100
Form-release compounds 250
Graphic arts coatings 500
(sign paints)
High temperature coatings 420
Impacted Immersion Coatings 780
Industrial maintenance coatings 250
Low solids coatings 120
Magnesite cement coatings 450
Mastic texture coatings 100
Metallic pigmented coatings 500
Multi-color coatings 250
Nuclear coatings 450
Pre-treatment wash primers 420
Primers, sealers, and 100
undercoaters
Reactive penetrating sealer 350
Reactive penetrating 500
carbonate stone sealer
Recycled coatings 250
Roof coatings 250
Rust preventative coatings 250
Shellacs:
Clear 730
Opaque 550
Specialty primers, sealers, 100
and undercoaters
Stains 250
Stone consolidant 450
Swimming pool coatings 340
Thermoplastic rubber coatings 550
and mastic
Traffic marking coatings 100
Tub and tile refinish 420
Waterproofing membranes 250
Wood coating 275
Wood Preservatives 350
Zinc-Rich Primer 340
(2) If a coating is recommended for use in more than one of the specialty coating categories listed in Table 1, the most restrictive (lowest) VOC content limit shall apply.
(a) This requirement applies to usage recommendations that appear anywhere on the coating container, anywhere on any label or sticker affixed to the container, or in any sales, advertising, or technical literature supplied by a manufacturer or anyone acting on their behalf.
(b) R307-361-5(2) does not apply to the following coating categories:
(i) Aluminum roof coatings
(ii) Bituminous roof primers
(iv) High temperature coatings
(v) Industrial maintenance coatings
(vi) Low-solids coatings
(vii) Metallic pigmented coatings
(viii) Pretreatment wash primers
(ix) Shellacs
(x) Specialty primers, sealers and undercoaters
(xi) Wood Coatings
(xii) Wood preservatives
(xiii) Zinc-rich primers
(xiv) Calcimine recoaters
(xv) Impacted immersion coatings
(xvi) Nuclear coatings
(xvii) Thermoplastic rubber coatings and mastic
(xviii) Concrete surface retarders
(xix) Conversion varnish
(3) Sell-through of coatings. A coating manufactured prior to January 1, 2015, may be sold, supplied, or offered for sale for up to three years after January 1, 2015.
(a) A coating manufactured before January 1, 2015, may be applied at any time.
(b) R307-361-5(3) does not apply to any coating that does not display the date or date code required by R307-361-6(1)(a).
(4) Painting practices. All architectural coating containers used when applying the contents therein to a surface directly from the container by pouring, siphoning, brushing, rolling, padding, ragging or other means, shall be closed when not in use. These architectural coating containers include, but are not limited to, drums, buckets, cans, pails, trays or other application containers. Containers of any VOC-containing materials used for thinning and cleanup shall also be closed when not in use.
(5) Thinning. No person who applies or solicits the application of any architectural coating shall apply a coating that is thinned to exceed the applicable VOC limit specified in Table 1.
(6) Rust preventative coatings. No person shall apply or solicit the application of any rust preventative coating manufactured before January 1, 2015 for industrial use, unless such a rust preventative coating complies with the industrial maintenance coating VOC limit specified in Table 1.
(7) Coatings not listed in Table 1. For any coating that does not meet any of the definitions for the specialty coatings categories listed in Table 1, the VOC content limit shall be determined by classifying the coating as a flat, non-flat, or non-flat/high gloss coating, based on its gloss, as defined in R307-361-3 and the corresponding flat, non-flat, or non-flat/high gloss coating VOC limit in Table 1 shall apply.