R307-335-5. Open Top Vapor Degreasers  


Latest version.
  • Owners or operators of open top vapor degreasers shall, in addition to meeting the requirements of R307-335-4(3), (4) and (5),

    (1) Equip the vapor degreaser with a cover that can be opened and closed without disturbing the vapor zone. The cover shall be closed except when processing work loads through the degreaser;

    (2) Install one of the following control devices:

    (a) Equipment necessary to sustain:

    (i) A freeboard ratio greater than or equal to 0.75, and

    (ii) A powered cover if the degreaser opening is greater than 1 square meter (10.8 square feet),

    (b) Refrigerated chiller,

    (c) Enclosed design (cover or door opens only when the dry part is actually entering or exiting the degreaser),

    (d) Carbon adsorption system, with ventilation greater than or equal to 15 cubic meters per minute per square meter (50 cubic feet per minute per square foot) of air/vapor area when cover is open and exhausting less than 25 parts per million of solvent averaged over one complete adsorption cycle;

    (3) Minimize solvent carryout by:

    (a) Racking parts to allow complete drainage,

    (b) Moving parts in and out of the degreaser at less than 3.3 meters per minute (11 feet per minute),

    (c) Holding the parts in the vapor zone at least 30 seconds or until condensation ceases,

    (d) Tipping out any pool of solvent on the cleaned parts before removal, and

    (e) Allowing the parts to dry within the degreaser for at least 15 seconds or until visibly dry.

    (4) Spray parts only in or below the vapor level;

    (5) Not use ventilation fans near the degreaser opening, nor provide exhaust ventilation exceeding 20 cubic meters per minute per square meter (65 cubic feet per minute per square foot) in degreaser open area, unless necessary to meet state and federal occupational, health, and safety requirements.

    (6) Not degrease porous or absorbent materials, such as cloth, leather, wood or rope;

    (7) Not allow work loads to occupy more than half of the degreaser's open top area;

    (8) Ensure that solvent is not visually detectable in water exiting the water separator;

    (9) Install safety switches on the following:

    (a) Condenser flow switch and thermostat (shuts off sump heat if condenser coolant is either not circulating or too warm); and

    (b) Spray switch (shuts off spray pump if the vapor level drops excessively, i.e., greater than 10 cm (4 inches).

    (10) Open top vapor degreasers with an open area smaller than one square meter (10.8 square feet) are exempt from R307-335-5(2)(b) and (d).