Summary
Subsection R313-38-3(4)(h) requires tests for leakage or contamination to be made pursuant to Section R313-15-1208. Section R313-15-1208 references Section R313-15-1401 which no longer exists. Therefore, Subsection R313-38-3(4)(h) is no longer valid and needs to be removed from the Utah Radiation Control Rules. Subsection R313-38-3(4)(e)(iii) is being added to Section R313-38-3 to substitute "Director" for "references to appropriate NRC Regional Office listed in appendix D of part 20 of this chapter" in 10 CFR 39.35(d)(2). Reports of test results for leaking or contaminated sealed sources will be made to the Director pursuant to the incorporation of 10 CFR 39.35(d)(2). Subsection R313-38-38-3(4)(e) incorrectly states "Director or the Director for references to:" This wording will be corrected to read "Director for references to:".