No. 41826 (Amendment): Rule R307-348. Magnet Wire Coatings  

  • (Amendment)

    DAR File No.: 41826
    Filed: 06/14/2017 04:46:18 PM

    RULE ANALYSIS

    Purpose of the rule or reason for the change:

    The purpose of this rule is to help reduce VOC emissions from sources that use magnet wire coatings. The amendments to this rule strengthen the area source coating rules. These amendments will help further reduce Volatile Organic Compound (VOC) emissions and will be part of the upcoming Serious PM2.5 State Implementation Plan (SIP).

    Summary of the rule or change:

    The applicability section is being amended from "potential to emit 2.7 tons per year or more of VOC" emissions to "sources that emit 2 tons per year or more of VOC emissions". The "add-on control system" and "recordkeeping" sections are also being amended to clarify the requirements of the rule.

    Statutory or constitutional authorization for this rule:

    Anticipated cost or savings to:

    the state budget:

    There will be no impact on the state budget because the state is not a source of magnet wire coating emissions.

    local governments:

    There will be no impact on the local government because the local governments are not a source of magnet wire coating emissions.

    small businesses:

    There will likely be no additional costs to small businesses because there are no new small businesses that are impacted by this rule.

    persons other than small businesses, businesses, or local governmental entities:

    Persons other than small businesses, businesses, or local government entities will not be impacted by this rule because the rule applicability threshold is set at a level that excludes hobbyists and other people that are not businesses or governments.

    Compliance costs for affected persons:

    The compliance cost for people who are affected by the rule will be about $6,857 per ton of VOC removed from the air.

    Comments by the department head on the fiscal impact the rule may have on businesses:

    After conducting a thorough analysis, it was determined that this proposed rule will not result in a fiscal impact to businesses. This is because the amendments to the rule did not bring in any new sources that were not already regulated by Rule R307-348, and the VOC content limits did not change.

    Alan Matheson, Executive Director

    The full text of this rule may be inspected, during regular business hours, at the Office of Administrative Rules, or at:

    Environmental Quality
    Air QualityRoom Fourth Floor
    195 N 1950 W
    SALT LAKE CITY, UT 84116-3085

    Direct questions regarding this rule to:

    Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

    08/15/2017

    Interested persons may attend a public hearing regarding this rule:

    • 07/27/2017 01:00 PM, DEQ Bldg, 195 N 1950 W, DEQ Board Room, Salt Lake City, UT

    This rule may become effective on:

    08/22/2017

    Authorized by:

    Bryce Bird, Director

    RULE TEXT

    R307. Environmental Quality, Air Quality.

    R307-348. Magnet Wire Coatings.

    R307-348-1. Purpose.

    The purpose of this rule is to limit volatile organic compound (VOC) emissions from [ovens of ]magnet wire coating operations.

     

    R307-348-2. Applicability.

    R307-348 applies to sources that emit 2 tons per year or more of VOC emissions, including related cleaning activities, that are located in Box Elder, Cache, Davis, Salt Lake, Tooele, Utah [and]or Weber counties[that have the potential to emit 2.7 tons per year or more of VOC, including related cleaning activities].

     

    R307-348-3. Definitions.

    The following additional definition applies to R307-348:

    "Magnet wire coating" means the process of applying coating of electrical insulating varnish or enamel to aluminum or copper wire for use in electrical machinery.

     

    R307-348-4. VOC Content Limit.

    [(1) ]No owner or operator [of a magnet wire coating oven may cause, allow or permit discharge into the atmosphere of any VOC in excess of 0.20 kilograms]shall apply coatings with a VOC content greater than 200 grams VOC per liter [of coating ](1.7 pounds per gallon), excluding water, and exempt solvents (compounds not classified as VOCs as defined in R307-101-2)[delivered to the coating applicator from magnet wire coating operations], unless the owner or operator uses an add-on control device as specified in R307-348-6.

    [(a) Equivalency calculations for coatings shall be performed in units of pounds VOCs per gallon of solid rather than pounds VOCs per gallon of coating when determining compliance.

    (b) The equivalent emission limit is 2.2 pounds VOCs per gallon solids.

    (2) The emission limitations specified above shall be achieved by:

    (a) The application of low solvent content coating technology; or

    (b) The use of an add-on control device on magnet wire coating ovens as specified in R307-348-6.]

     

    R307-348-5. Work Practices[ and Recordkeeping].

    (1) The owner or operator shall:

    (a) Store all VOC-containing coatings and cleaning materials in closed containers;

    (b) Minimize spills of VOC-containing coatings and cleaning materials;

    (c) Clean up spills immediately;

    (d) Convey any coatings, thinners, and cleaning materials in closed containers or pipes;

    (e) Close mixing vessels that contain VOC coatings and other materials except when specifically in use; and

    (f) Minimize usage of solvents during cleaning of storage, mixing, and conveying equipment.

    [(2) All sources subject to R307-348 shall maintain records demonstrating compliance with R307-348-4, and these records shall be available to the director upon request.]

     

    R307-348-6. Add-On Control Systems Operations.

    [(1) The owner or operator shall install and maintain an incinerator, carbon adsorption, or any other add-on emission control system, provided that the emission control system is operated and maintained in accordance with the manufacturer recommendations in order to maintain at least 90% capture and control efficiency. Determination of overall capture and control efficiency shall be determined using EPA approved methods, as follows.

    (a) The capture efficiency of a VOC emission control system's VOC collection device shall be determined according to EPA's "Guidelines for Determining Capture Efficiency," January 9, 1995 and 40 CFR Part 51, Appendix M, Methods 204-204F, as applicable.

    (b) The control efficiency of a VOC emission control system's VOC control device shall be determined using test methods in Appendices A-1, A-6, and A-7 to 40 CFR Part 60, for measuring flow rates, total gaseous organic concentrations, or emissions of exempt compounds, as applicable.]

    (1) If an add-on control system is used it must be installed, operated, and maintained in accordance with manufacturer recommendations.

    (a) An add-on control device must have a 90% or greater capture and control efficiency rating. Efficiency must be determined using EPA approved methods as follows:

    (i) Capture efficiency must be determined according to EPA's "Guidelines for Determining Capture Efficiency," January 9, 1995 and 40 C.F.R. Parts 51, Appendix M, Methods 204-204F, as applicable.

    (ii) Control efficiency must be determined using test methods in Appendices A-1, A-6, and A-7 to 40 C.F.R. Part 60, for measuring flow rates, total gaseous organic concentrations, or emissions of exempt compounds, as applicable.

    ([c]iii) An alternative test method may be substituted for the preceding test methods after review and approval by the EPA Administrator.

    [(2) The owner or operator of a control system shall provide documentation that the emission control system will attain the requirements of R307-348-6(1).

    (3) The owner or operator shall maintain records of key system parameters necessary to ensure compliance with R307-348-6. Key system parameters may include, but are not limited to, temperature, pressure and flow rates. Operator inspection schedule, monitoring, recordkeeping, and key parameters shall be in accordance with the manufacturer's recommendations, and as required to demonstrate operations are providing continuous emission reduction from the source during all periods that the operations cause emissions from the source.

    (4) The owner or operator shall maintain for a minimum of two years records of operating and maintenance sufficient to demonstrate that the equipment is being operated and maintained in accordance with the manufacturer recommendations.]

     

    R307-348-7. Recordkeeping.

    (1) The owner or operator shall maintain records of the following:

    (a) Records that demonstrate compliance with R307-348. Records must include, but are not limited to, inventory and product data sheets of all coatings and solvents subject to R307-348.

    (b) If an add-on control device is used, records of key system parameters necessary to ensure compliance with R307-348-6.

    (i) Key system parameters include, but are not limited to, temperature, pressure, flow rates, and an inspection schedule.

    (ii) Key inspection parameters must be in accordance with the manufacturer's recommendations, and as required to demonstrate operations are providing continuous emission reduction from the source during all periods that the operations cause emissions from the source.

    (2) All records must be maintained for a minimum of 2 years.

    (3) Records must be made available to the director upon request.

     

    KEY: air pollution, emission controls, surface coating s , magnet wires

    Date of Enactment or Last Substantive Amendment: [October 7, 2014]2017

    Authorizing, and Implemented or Interpreted Law: 19-2-104(1)(a)


Document Information

Hearing Meeting:
07/27/2017 01:00 PM, DEQ Bldg, 195 N 1950 W, DEQ Board Room, Salt Lake City, UT
Effective Date:
8/22/2017
Publication Date:
07/01/2017
Type:
Notices of Proposed Rules
Filed Date:
06/14/2017
Agencies:
Environmental Quality, Air Quality
Rulemaking Authority:

Section 19-2-104

Authorized By:
Bryce Bird, Director
DAR File No.:
41826
Summary:

The applicability section is being amended from "potential to emit 2.7 tons per year or more of VOC" emissions to "sources that emit 2 tons per year or more of VOC emissions". The "add-on control system" and "recordkeeping" sections are also being amended to clarify the requirements of the rule.

CodeNo:
R307-348
CodeName:
{34990|R307-348|R307-348. Magnet Wire Coatings}
Link Address:
Environmental QualityAir QualityRoom Fourth Floor 195 N 1950 WSALT LAKE CITY, UT 84116-3085
Link Way:

Ryan Stephens, by phone at 801-536-4419, by FAX at 801-536-0085, or by Internet E-mail at rstephens@utah.gov

AdditionalInfo:
More information about a Notice of Proposed Rule is available online. The Portable Document Format (PDF) version of the Bulletin is the official version. The PDF version of this issue is available at https://rules.utah.gov/publicat/bull_pdf/2017/b20170701.pdf. The HTML edition of the Bulletin is a convenience copy. Any discrepancy between the PDF version and HTML version is resolved in favor of the PDF version. Text to be deleted is struck through and surrounded by brackets ([example]). Text ...
Related Chapter/Rule NO.: (1)
R307-348. Magnet Wire Coatings.