No. 33555 (Amendment): Rule R313-21. General Licenses  

  • (Amendment)

    DAR File No.: 33555
    Filed: 04/13/2010 03:19:57 PM

    RULE ANALYSIS

    Purpose of the rule or reason for the change:

    This rule is being changed due to changes to the U.S. Nuclear Regulatory Commission's (NRC) regulations in 10 CFR Part 31 that were effective on 12/17/2007. The State has entered into an agreement with the NRC to establish and maintain a compatible program for the control of radioactive material in Utah. These changes are necessary to maintain the compatibility of the Utah Radiation Control Rules with federal regulations. There is also one typographical correction, and one correction of an incorrect rule citation.

    Summary of the rule or change:

    The rule change allows a licensee that has both a specific license and a general license to transfer a device from the general license to the specific license if: 1) the licensee's specific license allows for the possession of the device, or the specific license is amended to allow for possession of the device prior to the transfer; 2) the labeling on the device that is required because the device was initially distributed under a general license be removed or obliterated, and the device is labeled in accordance with Section R313-15-904 (including the manufacturer, model number and serial number); 3) the licensee obtains information concerning maintenance of the device that would be applicable under the specific license; and 4) the licensee reports the transfer to the Division. This rule does not require a licensee to transfer any device received under a general license to the licensee's specific license.

    State statutory or constitutional authorization for this rule:

    Anticipated cost or savings to:

    the state budget:

    The Division currently manages a specific licensing program and a general license program. A specific license is issued to an individual that contains specific requirements regarding the use of radioactive material by the individual. The individual must apply for and obtain the specific license prior to receiving radioactive material. A general license is issued by rule to anyone obtaining devices containing radioactive material that have been distributed to the licensee under certain conditions and requirements. After receiving the devices, the general licensee must register each device with the Division, and pay the annual fee of $20 per general license. The Division inspects specific and general licensees' compliance with the rules at specific intervals. Whenever possible, Division inspectors combine the inspection of devices licensed under the specific and general licenses held by the same licensee. However, there are times when Division inspectors travel to the same facility to perform the specific and general license inspections separately. There are currently 15 licensees with both a specific license and a general license that are regulated by the Division. If all of these licensees transferred their generally licensed devices to their specific licenses, the Division would not receive $300 per year in registration fees (General Fund revenues). However, the Division would no longer have data entry work to enter and remove each of these devices as the licensee received new devices or transferred/disposed of old devices. The Division would not have to generate and issue a separate general license registration certificate, send out revised certificates to the licensees as the licensees' device inventory changes, nor generate additional paperwork associated with a separate inspection of the devices. Also, there would be no need to visit the licensees' facilities more frequently than the specific license inspection frequency. While it is hard to estimate the actual cost savings to the Division, it is reasonable to assume that the Division would save more than $300 per year from the decreased registration and inspection activities associated with these licensees.

    local governments:

    Local governments would not be impacted fiscally since they are not involved in the regulation of general or specific radioactive material licenses. Also, none of the entities with both a specific license and a general license are local government agencies.

    small businesses:

    There is no anticipated fiscal affect on small businesses from the proposed rule changes, except for small businesses that possess both a specific license and a general license. The impact on affected small businesses is addressed below under "Compliance costs for affected persons."

    persons other than small businesses, businesses, or local governmental entities:

    There is no anticipated fiscal affect on other persons from the proposed rule changes, except for persons that possess both a specific license and a general license. The impact on affected persons is addressed below under "Compliance costs for affected persons."

    Compliance costs for affected persons:

    For those affected persons transferring devices possessed under their general license to their specific license, there will be an initial cost associated with changing the labeling on each device to conform with the labeling of devices possessed under a specific license, and the affected person will have to report the transfer of the devices to the Division. The affected person can modify the device labels himself, or the affected person can employ a service technician to perform this work. In those cases where the specific license will need to be amended prior to transferring the devices, the affected person will have to prepare and submit an amendment request to the Division. The costs associated with these actions are anticipated to be one-time expenses. Since each affected person will deal with these expenses in a unique manner, it is difficult to estimate the total cost to persons affected by this rule, but it is expected that the costs will be minimal for each affected person. Also, affected persons are not required to transfer devices from their general license to their specific license by the proposed rule change. Affected persons may have additional costs associated with required sealed source leak testing (for any contamination), physical inventories, and shutter checks; however, most of these required activities are likely to occur at the same frequency for the devices regardless of the license type. Affected persons who transfer all of their devices to a specific license will save $20 per year in general license fees, and the affected persons will no longer incur expenses associated with reporting inventory changes to the Division as required for devices under a general license.

    Comments by the department head on the fiscal impact the rule may have on businesses:

    The proposed changes to the rule are necessary for the Utah Radiation Control Rules to be compatible with NRC requirements, and the Division's program activities are adequate to protect the public health and safety. While there may be a small cost incurred by businesses opting to transfer devices containing radioactive material from a general license to a specific license, it is believed that businesses will benefit from the reduced on-going regulatory expenses and a simplified regulatory process by having only one license with the Division.

    Amanda Smith, Executive Director

    The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:

    Environmental Quality
    Radiation Control
    168 N 1950 W
    SALT LAKE CITY, UT 84116-3085

    Direct questions regarding this rule to:

    Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

    05/31/2010

    This rule may become effective on:

    06/09/2010

    Authorized by:

    Dane Finerfrock, Director

    RULE TEXT

    R313. Environmental Quality, Radiation Control.

    R313-21. General Licenses.

    R313-21-22. General Licenses*--Radioactive Material Other Than Source Material.

    NOTE: *Different general licenses are issued in this section, each of which has its own specific conditions and requirements.

    (1) Certain devices and equipment. A general license is hereby issued to transfer, receive, acquire, own, possess, and use radioactive material incorporated in the following devices or equipment which have been manufactured, tested and labeled by the manufacturer in accordance with a specific license issued to the manufacturer by the Executive Secretary, the Nuclear Regulatory Commission, an Agreement State, or a Licensing State for use pursuant to 10 CFR 31.3. This general license is subject to the provisions of R313-12-51 through R313-12-70, R313-14, R313-15, R313-18 and R313-19 as applicable.

    (a) Static Elimination Devices. Devices designed for use as static eliminators which contain, as a sealed source or sources, radioactive material consisting of a total of not more than 18.5 megabecquerel (500 uCi) of polonium-210 per device.

    (b) Ion Generating Tube. Devices designed for ionization of air which contain, as a sealed source or sources, radioactive material consisting of a total of not more than 18.5 megabecquerel (500 uCi) of polonium-210 per device or a total of not more than 1.85 gigabecquerel (50 mCi) of hydrogen-3 (tritium) per device.

    (2) RESERVED.

    (3) RESERVED.

    (4) Certain detecting, measuring, gauging or controlling devices and certain devices for producing light or an ionized atmosphere.*

    NOTE: *Persons possessing radioactive material in devices under a general license in R313-21-22(4) before January 15, 1975, may continue to possess, use, or transfer that material in accordance with the labeling requirements of R313-21-22(4) in effect on January 14, 1975.

    (a) A general license is hereby issued to commercial and industrial firms and research, educational and medical institutions, individuals in the conduct of their business, and state or local government agencies to own, acquire, receive, possess, use or transfer, in accordance with the provisions of R313-21-22(4)(b), (c) and (d), radioactive material, excluding special nuclear material, contained in devices designed and manufactured for the purpose of detecting, measuring, gauging or controlling thickness, density, level, interface location, radiation, leakage, or qualitative or quantitative chemical composition, or for producing light or an ionized atmosphere.

    (b)(i) The general license in R313-21-22(4)(a) applies only to radioactive material contained in devices which have been manufactured or initially transferred and labeled in accordance with the specifications contained in:

    (A) a specific license issued by the Executive Secretary pursuant to R313-22-75(4); or

    (B) an equivalent specific license issued by the Nuclear Regulatory Commission, an Agreement State or a Licensing State.*

    NOTE: *Regulations under the Federal Food, Drug, and Cosmetic Act authorizing the use of radioactive control devices in food production require certain additional labeling thereon which is found in 21 CFR 179.21.

    (ii) The devices must have been received from one of the specific licensees described in R313-21-22(4)(b)(i) or through a transfer made under R313-21-22(4)(c)(ix).

    (c) Any person who owns, acquires, receives, possesses, uses or transfers radioactive material in a device pursuant to the general license in R313-21-22(4)(a):

    (i) shall assure that all labels affixed to the device at the time of receipt and bearing a statement that removal of the label is prohibited are maintained thereon and shall comply with all instructions and precautions provided by the labels;

    (ii) shall assure that the device is tested for leakage of radioactive material and proper operation of the on-off mechanism and indicator, if any, at no longer than six-month intervals or at other intervals as are specified in the label; however:

    (A) Devices containing only krypton need not be tested for leakage of radioactive material, and

    (B) Devices containing only tritium or not more than 3.7 megabecquerel (100 uCi) of other beta, gamma, or both, emitting material or 0.37 megabecquerel (10 uCi) of alpha emitting material and devices held in storage in the original shipping container prior to initial installation need not be tested for any purpose;

    (iii) shall assure that other testing, installation, servicing, and removal from installation involving the radioactive materials, its shielding or containment, are performed:

    (A) in accordance with the instructions provided by the labels; or

    (B) by a person holding a specific license pursuant to R313-22 or from the Nuclear Regulatory Commission, an Agreement State, or a Licensing State to perform such activities;

    (iv) shall maintain records showing compliance with the requirements of R313-21-22(4)(c)(ii) and (iii). The records shall show the results of tests. The records also shall show the dates of performance of, and the names of persons performing, testing, installation, servicing, and removal from the installation the radioactive material and its shielding or containment. The licensee shall retain these records as follows:

    (A) Each record of a test for leakage [or]of radioactive material required by R313-21-22(4)(c)(ii) shall be retained for three years after the next required leak test is performed or until the sealed source is transferred or disposed of;

    (B) Each record of a test of the on-off mechanism and indicator required by R313-21-22(4)(c)(ii) shall be retained for three years after the next required test of the on-off mechanism and indicator is performed or until the sealed source is transferred or disposed of;

    (C) Each record that is required by R313-21-22(4)(c)(iii) shall be retained for three years from the date of the recorded event or until the device is transferred or disposed of;

    (v) shall immediately suspend operation of the device if there is a failure of, or damage to, or any indication of a possible failure of or damage to, the shielding of the radioactive material or the on-off mechanism or indicator, or upon the detection of 185 becquerel (0.005 uCi) or more removable radioactive material. The device may not be operated until it has been repaired by the manufacturer or other person holding a specific license to repair the device that was issued by the Executive Secretary, the Nuclear Regulatory Commission, an Agreement State, or a Licensing State. The device and any radioactive material from the device may only be disposed of by transfer to a person authorized by a specific license to receive the radioactive material in the device or as otherwise approved by the Executive Secretary, the Nuclear Regulatory Commission, an Agreement State, or a Licensing State. A report containing a brief description of the event and the remedial action taken; and, in the case of detection of 185 becquerel (0.005 uCi) or more removable radioactive material or failure of or damage to a source likely to result in contamination of the premises or the environs, a plan for ensuring that the premises and environs are acceptable for unrestricted use, must be furnished to the Executive Secretary within 30 days. Under these circumstances, the criteria set out in R313-15-402 may be applicable, as determined by the Executive Secretary on a case-by-case basis;

    (vi) shall not abandon the device containing radioactive material;

    (vii) shall not export the device containing radioactive materials except in accordance with 10 CFR 110;

    (viii)(A) shall transfer or dispose of the device containing radioactive material only by export as provided by R313-21-22(4)(c)(vii), by transfer to another general licensee as authorized in R313-21-22(4)(c)(ix), to a person authorized to receive the device by a specific license issued under R313-22, to an authorized waste collector under R313-25, or equivalent regulations of the Nuclear Regulatory Commission, an Agreement State, or a Licensing State , or as otherwise approved under R313-21-22(4)(c)(viii)(C);

    (B) shall furnish a report to the Executive Secretary within 30 days after transfer of a device to a specific licensee or export. The report must contain:

    (I) the identification of the device by manufacturer's or initial transferor's name, model number, and serial number;

    (II) the name, address, and license number of the person receiving the device, the license number is not applicable if exported; and

    (III) the date of the transfer;

    (C) shall obtain written approval from the Executive Secretary before transferring the device to any other specific licensee not specifically identified in R313-21-22(4)(c)(viii)(A); however, a holder of a specific license may transfer a device for possession and use under its own specific license without prior approval, if, the holder:

    (I) verifies that the specific license authorizes the possession and use, or applies for and obtains an amendment to the license authorizing the possession and use;

    (II) removes, alters, covers, or clearly and unambiguosly augments the existing label (otherwise required by R313-21-22(4)(c)(i)) so that the device is labeled in compliance with R313-15-904; however, the manufacturer, model number, and serial number must be retained;

    (III) obtains the manufacturer's or initial transferor's information concerning maintenance that would be applicable under the specific license (such as leak testing procedures); and

    (IV) reports the transfer under R313-21-22(4)(c)(viii)(B);

    (ix) shall transfer the device to another general licensee only if:

    (A) the device remains in use at a particular location. In this case, the transferor shall give the transferee a copy of R313-21-22(4), R313-12-51, R313-15-1201, and R313-15-1202, and any safety documents identified in the label of the device. Within 30 days of the transfer, the transferor shall report to the Executive Secretary:

    (I) the manufacturer's or initial transferor's name;

    (II) the model number and serial number of the device transferred;

    (III) the transferee's name and mailing address for the location of use; and

    (IV) the name, title, and phone number of the responsible individual identified by the transferee in accordance with R313-21-22(4)(c)(xii) to have knowledge of and authority to take actions to ensure compliance with the appropriate regulations and requirements; or

    (B) the device is held in storage by an intermediate person in the original shipping container at its intended location of use prior to initial use by a general licensee;

    (x) shall comply with the provisions of R313-15-1201 and R313-15-1202 for reporting radiation incidents, theft or loss of licensed material, but shall be exempt from the other requirements of R313-15 and R313-18;

    (xi) shall respond to written requests from the Executive Secretary to provide information relating to the general license within 30 calendar days of the date of the request, or other time specified in the request. If the general licensee cannot provide the requested information within the allotted time, it shall, within that same time period, request a longer period to supply the information by submitting a letter to the Executive Secretary and provide written justification as to why it cannot comply;

    (xii) shall appoint an individual responsible for having knowledge of the appropriate regulations and requirements and the authority for taking required actions to comply with appropriate regulations and requirements. The general licensee, through this individual, shall ensure the day-to-day compliance with appropriate regulations and requirements. This appointment does not relieve the general licensee of any of its responsibility in this regard;

    (xiii)(A) shall register, in accordance with R313-21-22(4)(c)(xiii)(B) and (C), devices containing at least 370 megabecquerel (ten mCi) of cesium-137, 3.7 megabecquerel (0.1 mCi) of strontium-90, 37 megabecquerel (one mCi) of cobalt-60, 3.7 megabecquerel (0.1 mCi) of radium-226, or 37 megabecquerel (one mCi) of americium-241 or any other transuranic, (elements with atomic number greater than uranium-92), based on the activity indicated on the label. Each address for a location of use, as described under R313-21-22(4)(c)(xiii)(C)(IV) represents a separate general licensee and requires a separate registration and fee;

    (B) if in possession of a device meeting the criteria of R313-21-22(4)(c)(xiii)(A), shall register these devices annually with the Executive Secretary and shall pay the fee required by R313-70. Registration shall include verifying, correcting, or adding, as appropriate, to the information provided in a request for registration received from the Executive Secretary. The registration information must be submitted to the Executive Secretary within 30 days of the date of the request for registration or as otherwise indicated in the request. In addition, a general licensee holding devices meeting the criteria of R313-21-22(4)(c)(xiii)(A) is subject to the bankruptcy notification requirement in R313-19-34(5) and (6);

    (C) in registering devices, the general licensee shall furnish the following information and any other information specifically requested by the Executive Secretary:

    (I) name and mailing address of the general licensee;

    (II) information about each device: the manufacturer or initial transferor, model number, serial number, the radioisotope and activity as indicated on the label;

    (III) name, title, and telephone number of the responsible person designated as a representative of the general licensee under R313-21-22(4)(c)(xii);

    (IV) address or location at which the device(s) are used, stored, or both. For portable devices, the address of the primary place of storage;

    (V) certification by the responsible representative of the general licensee that the information concerning the device(s) has been verified through a physical inventory and checking of label information; and

    (VI) certification by the responsible representative of the general licensee that they are aware of the requirements of the general license; and

    (D) persons generally licensed by the Nuclear Regulatory Commission, an Agreement State, or Licensing State with respect to devices meeting the criteria in R313-21-22(4)(c)(xiii)(A) are not subject to registration requirements if the devices are used in areas subject to Division jurisdiction for a period less than 180 days in any calendar year. The Executive Secretary will not request registration information from such licensees;

    (xiv) shall report changes to the mailing address for the location of use, including changes in the name of a general licensee, to the Executive Secretary within 30 days of the effective date of the change. For a portable device, a report of address change is only required for a change in the device's primary place of storage; and

    (xv) may not hold devices that are not in use for longer than 2 years. If devices with shutters are not being used, the shutter must be locked in the closed position. The testing required by R313-21-22(4)(c)(ii) need not be performed during the period of storage only. However, when devices are put back into service or transferred to another person, and have not been tested within the required test interval, they must be tested for leakage before use or transfer and the shutter tested before use. Devices kept in standby for future use are excluded from the two-year time limit if the general licensee performs quarterly physical inventories of these devices while they are in standby.

    (d) The general license in R313-21-22(4)(a) does not authorize the manufacture or import of devices containing radioactive material.

    (e) The general license provided in R313-21-22(4)(a) is subject to the provisions of R313-12-51 through R313-12-53, R313-12-70, R313-14, R313-19-34, R313-19-41, R313-19-61, and R313-19-100.

    (5) Luminous safety devices for aircraft.

    (a) A general license is hereby issued to own, receive, acquire, possess and use tritium or promethium-147 contained in luminous safety devices for use in aircraft, provided:

    (i) each device contains not more than 370.0 gigabecquerel (10 Ci) of tritium or 11.1 gigabecquerel (300 mCi) of promethium-147; and

    (ii) each device has been manufactured, assembled or initially transferred in accordance with a specific license issued by the Nuclear Regulatory Commission or an Agreement State, or each device has been manufactured or assembled in accordance with the specifications contained in a specific license issued by the Executive Secretary or an Agreement State to the manufacturer or assembler of the device pursuant to licensing requirements equivalent to those in R313-22-75(5).

    (b) Persons who own, receive, acquire, possess or use luminous safety devices pursuant to the general license in R313-21-22(5) are exempt from the requirements of R313-15 and R313-18, except that they shall comply with the provisions of R313-15-1201 and R313-15-1202.

    (c) This general license does not authorize the manufacture, assembly, repair, or import of luminous safety devices containing tritium or promethium-147.

    (d) This general license does not authorize the export of luminous safety devices containing tritium or promethium-147.

    (e) This general license does not authorize the ownership, receipt, acquisition, possession or use of promethium-147 contained in instrument dials.

    (f) This general license is subject to the provisions of R313-12-51 through R313-12-70, R313-14, R313-19-34, R313-19-41, R313-19-61, and R313-19-100.

    (6) Ownership of radioactive material. A general license is hereby issued to own radioactive material without regard to quantity. Notwithstanding any other provisions of R313-21, this general license does not authorize the manufacture, production, transfer, receipt, possession, use, import, or export of radioactive material except as authorized in a specific license.

    (7) Calibration and reference sources.

    (a) A general license is hereby issued to own, receive, acquire, possess, use and transfer, in the form of calibration or reference sources, americium-241, plutonium or radium-226 in accordance with the provisions of R313-21-22(7)(b) and (c), to a person who holds a specific license issued by the Executive Secretary which authorizes that person to receive, possess, use and transfer radioactive material.

    (b) The general license in R313-21-22(7)(a) applies only to calibration or reference sources which have been manufactured or initially transferred in accordance with the specifications contained in a specific license issued to the manufacturer or importer of the sources by the Nuclear Regulatory Commission pursuant to 10 CFR 32.57 or 10 CFR 70.39 or which have been manufactured in accordance with the specifications contained in a specific license issued to the manufacturer by the Executive Secretary, a Licensing State, or an Agreement State in accordance with requirements equivalent to 10 CFR 32.57 or 10 CFR 70.39.

    (c) The general license provided in R313-21-22(7)(a) is subject to the provisions of R313-12-51 through R313-12-53, R313-12-70, R313-14, R313-19-34, R313-19-41, R313-19-61, R313-19-100, R313-15 and R313-18. In addition, persons who own, receive, acquire, possess, use or transfer one or more calibration or reference sources pursuant to these general licenses:

    (i) shall not possess at any one time, at any one location of storage or use, more than 185.0 kilobecquerel (5 uCi) of americium-241, 185.0 kilobecquerel (5 uCi) of plutonium, or 185.0 kilobecquerel (5 uCi) of radium-226 in such source;

    (ii) shall not receive, possess, use or transfer a source unless the source, or the storage container, bears a label which includes one of the following statements or a substantially similar statement which contains the information called for in the following statement:

    The receipt, possession, use and transfer of this source, Model No. ..............., Serial No. ..............., are subject to a general license and the regulations of the United States Nuclear Regulatory Commission or of a state with which the Commission has entered into an agreement for the exercise of regulatory authority. Do not remove this label.

    CAUTION - RADIOACTIVE MATERIAL

    THIS SOURCE CONTAINS (AMERICIUM-241)(PLUTONIUM)(RADIUM-226)*

    DO NOT TOUCH RADIOACTIVE PORTION OF THIS SOURCE.

    .....................................................

    Typed or printed name of the manufacturer or initial transferor

    NOTE: *Show the name of the appropriate material.

    (iii) shall not transfer, abandon, or dispose of a source except by transfer to a person authorized by a license from the Executive Secretary, the Nuclear Regulatory Commission, an Agreement State, or a Licensing State to receive the source;

    (iv) shall store a source, except when the source is being used, in a closed container adequately designed and constructed to contain americium-241, plutonium, or radium-226 which might otherwise escape during storage; and

    (v) shall not use a source for any purpose other than the calibration of radiation detectors or the standardization of other sources.

    (f) These general licenses do not authorize the manufacture, import, or export of calibration or reference sources containing americium-241, plutonium, or radium-226.

    (8) RESERVED.

    (9) General license for use of radioactive material for certain in vitro clinical or laboratory testing.*

    NOTE: *The New Drug provisions of the Federal Food, Drug and Cosmetic Act also govern the availability and use of any specific diagnostic drug in interstate commerce.

    (a) A general license is hereby issued to any physician, veterinarian in the practice of veterinary medicine, clinical laboratory or hospital to receive, acquire, possess, transfer or use, for the following stated tests, in accordance with the provisions of R313-21-22(9) (b), (c), (d), (e), and (f) the following radioactive materials in prepackaged units for use in in-vitro clinical or laboratory tests not involving internal or external administration of radioactive material, or the radiation therefrom, to human beings or animals:

    (i) iodine-125, in units not exceeding 370.0 kilobecquerel (10 uCi) each;

    (ii) iodine-131, in units not exceeding 370.0 kilobecquerel (10 uCi) each;

    (iii) carbon-14, in units not exceeding 370.0 kilobecquerel (10 uCi) each;

    (iv) hydrogen-3 (tritium), in units not exceeding 1.85 megabecquerel (50 uCi) each;

    (v) iron-59, in units not exceeding 740.0 kilobecquerel (20 uCi) each;

    (vi) cobalt-57, in units not exceeding 370.0 kilobecquerel (10 uCi) each;

    (vii) selenium-75, in units not to exceed 370.0 kilobecquerel (10 uCi) each; or

    (viii) mock iodine-125, reference or calibration sources, in units not exceeding 1.85 kilobecquerel (0.05 uCi) of iodine-129 and 185.0 becquerel (0.005 uCi) of americium-241 each.

    (b) A person shall not receive, acquire, possess, use or transfer radioactive material pursuant to the general license established by R313-21-22(9)(a) until that person has filed form DRC-07, "Registration Form-In Vitro Testing with Radioactive Material Under General License," with the Executive Secretary and received a Certificate of Registration signed by the Executive Secretary, or until that person has been authorized pursuant to R313-32 to use radioactive material under the general license in R313-21-22(9). The physician, veterinarian, clinical laboratory or hospital shall furnish on form DRC-07 the following information and other information as may be required by that form:

    (i) name and address of the physician, veterinarian, clinical laboratory or hospital;

    (ii) the location of use; and

    (iii) a statement that the physician, veterinarian, clinical laboratory or hospital has appropriate radiation measuring instruments to carry out in vitro clinical or laboratory tests with radioactive material as authorized under the general license in R313-21-22(9)(a) and that the tests will be performed only by personnel competent in the use of radiation measuring instruments and in the handling of the radioactive material.

    (c) A person who receives, acquires, possesses or uses radioactive material pursuant to the general license established by R313-21-22(9)(a) shall comply with the following:

    (i) The general licensee shall not possess at any one time, pursuant to the general license in R313-21-22(9)(a) at any one location of storage or use, a total amount of iodine-125, iodine-131, selenium-75, iron-59, cobalt-57, or any combination, in excess of 7.4 megabecquerel (200 uCi).

    (ii) The general licensee shall store the radioactive material, until used, in the original shipping container or in a container providing equivalent radiation protection.

    (iii) The general licensee shall use the radioactive material only for the uses authorized by R313-21-22(9)(a).

    (iv) The general licensee shall not transfer the radioactive material except to a person authorized to receive it pursuant to a license issued by the Executive Secretary, the Nuclear Regulatory Commission, an Agreement State or Licensing State, nor transfer the radioactive material in a manner other than in the unopened, labeled shipping container as received from the supplier.

    (v) The general licensee shall dispose of the Mock Iodine-125 reference or calibration sources described in R313-21-22(9)(a)(viii) as required by R313-15-1001.

    (vi) The general licensee shall pay annual fees pursuant to R313-70.

    (d) The general licensee shall not receive, acquire, possess, or use radioactive material pursuant to R313-21-22(9)(a):

    (i) Except as prepackaged units which are labeled in accordance with the provision of a specific license issued pursuant to R313-22-75([8]7) or in accordance with the provisions of a specific license issued by the Nuclear Regulatory Commission, an Agreement State, or a Licensing State which authorizes the manufacture and distribution of iodine-125, iodine-131, carbon-14, hydrogen-3(tritium), iron-59, selenium-75, cobalt-57, or Mock Iodine-125 to persons generally licensed under R313-22(9) or its equivalent, and

    (ii) Unless the following statement, or a substantially similar statement which contains the information called for in the following statement, appears on a label affixed to each prepackaged unit or appears in a leaflet or brochure which accompanies the package:

    "This radioactive material shall be received, acquired, possessed and used only by physicians, veterinarians in the practice of veterinary medicine, clinical laboratories or hospitals and only for in vitro clinical or laboratory tests not involving internal or external administration of the material, or the radiation therefrom, to human beings or animals. Its receipt, acquisition, possession, use and transfer are subject to the regulations and a general license of the United States Nuclear Regulatory Commission or of a state with which the Commission has entered into an agreement for the exercise of regulatory authority.

    .........................

    Name of Manufacturer"

    (e) The physician, veterinarian, clinical laboratory or hospital possessing or using radioactive material under the general license in R313-21-22(9)(a) shall report in writing to the Executive Secretary, changes in the information previously furnished in the "Registration Form-In Vitro Testing with Radioactive Material Under General License", form DRC -07. The report shall be furnished within 30 days after the effective date of the change.

    (f) Any person using radioactive material pursuant to the general license of R313-21-22(9)(a) is exempt from the requirements of R313-15 and R313-18 with respect to radioactive material covered by that general license, except that persons using the Mock Iodine-125 described in R313-21-22(9)(a)(viii) shall comply with the provisions of R313-15-1001, R313-15-1201 and R313-15-1202.

    (10) Ice Detection Devices.

    (a) A general license is hereby issued to own, receive, acquire, possess, use and transfer strontium-90 contained in ice detection devices, provided each device contains not more than 1.85 megabecquerel (50 uCi) of strontium-90 and each device has been manufactured or initially transferred in accordance with a specific license issued by the Nuclear Regulatory Commission, or each device has been manufactured in accordance with the specifications contained in a specific license issued by the Executive Secretary, an Agreement State, or a Licensing State to the manufacturer of the device pursuant to licensing requirements equivalent to those in 10 CFR 32.61.

    (b) Persons who own, receive, acquire, possess, use or transfer strontium-90 contained in ice detection devices pursuant to the general license in R313-21-22(10)(a):

    (i) shall, upon occurrence of visually observable damage, such as a bend or crack or discoloration from over-heating to the device, discontinue use of the device until it has been inspected, tested for leakage and repaired by a person holding a specific license from the Executive Secretary, the Nuclear Regulatory Commission, an Agreement State, or a Licensing State to manufacture or service the device; or shall dispose of the device pursuant to the provisions of R313-15-1001;

    (ii) shall assure that all labels affixed to the device at the time of receipt, and which bear a statement which prohibits removal of the labels, are maintained thereon; and

    (iii) are exempt from the requirements of R313-15 and R313-18 except that the persons shall comply with the provisions of R313-15-1001, R313-15-1201 and R313-15-1202.

    (c) This general license does not authorize the manufacture, assembly, disassembly, repair, or import of strontium-90 in ice detection devices.

    (d) This general license is subject to the provision of R313-12-51 through R313-12-53, R313-12-70, R313-14, R313-19-34, R313-19-41, R313-19-61, and R313-19-100 of these rules.

     

    KEY: radioactive materials, general licenses, source materials

    Date of Enactment or Last Substantive Amendment: [February 11, 2009] June 9, 2010

    Notice of Continuation: October 14, 2008

    Authorizing, and Implemented or Interpreted Law: 19-3-104

     


Document Information

Effective Date:
6/9/2010
Publication Date:
05/01/2010
Filed Date:
04/13/2010
Agencies:
Environmental Quality,Radiation Control
Rulemaking Authority:

Subsection 19-3-104(8)

Subsection 19-3-104(4)

Authorized By:
Dane Finerfrock, Director
DAR File No.:
33555
Related Chapter/Rule NO.: (1)
R313-21. General Licenses.