-
DAR File No.: 29009
Filed: 01/12/2007, 03:15
Received by: NLRULE ANALYSIS
Purpose of the rule or reason for the change:
The purpose of this change is to replace, based on public comments the term volatile organic compound with "VOC" throughout Rule R307-340. In addition, the Board made other minor grammatical correction throughout Rule R307-340. This change in proposed rule (CPR) is part of revisions to rules related to the ozone maintenance plan (see separate filings in this issue.) (DAR NOTE: The other CPR filings are under: Sections R307-101-2 (DAR No. 29000) and R307-110-13 (DAR No. 29001); and Rules R307-320 (DAR No. 29002); R307-325 (DAR No. 29003); R307-326 (DAR No. 29006); R307-327 (DAR No. 29004); and R307-343 (DAR No. 29012) in this issue.)
Summary of the rule or change:
In response to public comment, the Utah Air Quality Board replaced the term volatile organic compound with "VOC" throughout Rule R307-340. In addition, the Board made other minor grammatical correction throughout Rule R307-340.
State statutory or constitutional authorization for this rule:
Subsection 19-2-104(1)(a)
Anticipated cost or savings to:
the state budget:
Because these revisions do not create any new requirements, no change in costs is expected to the state budget.
local governments:
Because these revisions do not create any new requirements, no change in costs is expected for local governments.
other persons:
Because these revisions do not create any new requirements, no change in costs is expected for other persons.
Compliance costs for affected persons:
Because these revisions do not create any new requirements, no change in costs is expected for affected persons.
Comments by the department head on the fiscal impact the rule may have on businesses:
Because these revisions do not create new requirements, no change to costs is expected for businesses. Dianne R. Nielson, Executive Director
The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:
Environmental Quality
Air Quality
150 N 1950 W
SALT LAKE CITY UT 84116-3085Direct questions regarding this rule to:
Mat E. Carlile at the above address, by phone at 801-536-4136, by FAX at 801-536-0085, or by Internet E-mail at MCARLILE@utah.gov
This rule may become effective on:
03/06/2007
Authorized by:
M. Cheryl Heying, Planning Branch Manager
RULE TEXT
R307. Environmental Quality, Air Quality.
R307-340. Ozone Nonattainment and Maintenance Areas: Surface Coating Processes.
. . . . . . .
R307-340-4. General Provisions for Volatile Organic Compounds.
(1) Fugitive emissions. Control techniques and work practices are to be implemented at all times to reduce volatile organic compound (VOC) emissions from fugitive type sources. Control techniques and work practices include:
(a) tight fitting covers for open tanks;
(b) covered containers for solvent wiping cloths;
(c) collection hoods for areas where solvent is used for cleanup; and
(d) proper disposal of dirty cleanup solvent.
(2) Record keeping and reporting.
(a) The owner or operator of any source subject to R307-340 shall maintain:
(i) Records detailing all malfunctions affecting control equipment;
(ii) Records of all testing conducted under R307-340-15;
(iii) Records of all monitoring conducted under R307-340-15; and
(iv) Records of the daily use of all paints, stains, lacquers, solvents, and other materials that may be a source of VOC emissions.
(v) The recording format shall, at a minimum, follow the guidance in EPA-340/1-88-003, "Recordkeeping Guidance Document for Surface Coating Operations and the Graphic Arts Industry", or the most recent EPA guidance, and shall contain all information necessary to determine compliance with emissions limits on a daily basis.
(b) The owner or operator shall:
(i) Install; operate; and maintain process or control equipment, or both; monitoring instruments or procedures; as necessary to comply with (2)(a) above; and
(ii) Maintain, in writing, data or reports, or both, relating to monitoring instruments or procedures to document, upon review, the compliance status of the VOC emission source or control equipment.
(c) Copies of all records and reports required by (2)(a) and (b) above shall be retained by the owner or operator for a minimum of two years after the date on which the record was made, and shall be made available to the executive secretary or representative upon verbal or written request.
(d) If add-on control equipment is used, in addition to the requirements of R307-340-15(5), the following information, as determined applicable for each source by the executive secretary, shall be monitored and recorded daily in order to assure continuous compliance. The substitution of continuous recordings of system operation for daily recordings may be allowed by the executive secretary. The required information pertains to the following systems:
(i) capture systems: fan power use, duct flow, and duct pressure.
(ii) carbon absorbers systems: bed temperature, bed vacuum pressure, pressure at the vacuum pump, accumulated time of operation, concentration of VOCs in the outlet gas, and solvent recovery.
(iii) refrigeration systems: compressor discharge and suction pressures, condenser fluid temperature, and solvent recovery.
(iv) incinerator systems: exhaust gas temperature, temperature rise across a catalytic incinerator bed, flame temperature, and accumulated time of incineration.
(3) Malfunctions, Breakdowns, and Upsets. The owner or operator of a surface coating installation shall maintain a record of malfunctions, breakdowns, and upsets that result in excess VOC emissions. The record shall be kept for a calendar year and shall be submitted to the executive secretary by April 1 of the following year.
(4) Disposal of waste solvents. Waste solvents or waste materials that contain solvents shall be disposed of by recycling, reclaiming or by incineration in an incinerator approved to process hazardous materials or by an alternate means approved by the executive secretary.
(5) Compliance Calculation Procedures.
(a) Compliance with R307-340 shall be determined on a daily basis. Sources may request approval for longer times for compliance determination from the executive secretary.
(b) Compliance calculation procedures shall follow the guidance of "Procedures for Certifying Quantity of [
Volatile Organic Compounds]VOCs Emitted by Paint, Ink, and other Coatings," EPA-450/3-84-019, or the most recent EPA guidance. Sources that use add-on controls, or an approved alternative strategy instead of low solvent technology to meet the applicable emission limit, shall meet the equivalent VOCs emission limit on the basis of solids applied (lbs. VOCs/gallon solids applied, or lbs. VOCs/lb. solids applied, for graphic arts sources).R307-340-5. Paper Coating.
(1) R307-340-5 applies to roll, knife rotogravure coaters and drying ovens of paper coating operations.
(2) No owner or operator of a paper coating operation subject to R307-340-5 may cause, allow or permit the discharge into the atmosphere of any VOC in excess of 0.35 kilograms per liter of coating (2.9 pounds per gallon), excluding water and solvents exempt from the definition of [
volatile organic compounds]VOC, delivered to the coating application from a paper coating operation.(3) Equivalency calculations for coatings should be performed in units of lbs. VOCs/gallon of solid rather than lbs. VOC/gallon of coating when determining compliance. The equivalent emission limit is 4.8 lbs. VOC/gallon of solid.
(4) The emission limit specified above shall be achieved by:
(a) The application of a low solvent technology coating; or
(b) Incineration, provided that a minimum of 90 percent of non-methane [
volatile organic compounds]VOCs (VOCs measured as total combustible carbon) that enter the incinerator are oxidized to carbon dioxide and water; or(c) Through carbon adsorption provided that there is a minimum of 90% reduction efficiency of captured VOC emissions.
(5) The design, operation, and efficiency of any capture system used in conjunction with (4) above shall be certified in writing by the owner or operator and approved by the executive secretary.
R307-340-6. Fabric and Vinyl Coating.
(1) R307-340-6 applies to roll, knife or rotogravure coaters and drying ovens of fabric and vinyl coating operations.
(2) No owner or operator of a fabric or vinyl coating line subject to this section may cause, allow or permit the discharge into the atmosphere of any [
volatile organic compounds]VOCs in excess of:(a) 0.35 kilograms per liter of coating (2.9 pounds per gallon), excluding water and solvents exempt from the definition of [
volatile organic compound]VOC, delivered to the coating applicator from a fabric coating line; or(b) 0.45 kilograms per liter of coating (3.8 pounds per gallon), excluding water and solvents exempt from the definition of [
volatile organic compound]VOC, delivered to the coating applicator from a vinyl coating line.(3) Equivalency calculations for coatings shall be performed in units of lbs. VOCs/gallon[
s] of solids rather than lbs. VOCs/gallon of coating when determining compliance. The equivalent emission limits shall be 4.8 lbs VOCs/gallon solids for fabric coating, and 7.9 lbs VOCs/gallon for vinyl coating.(4) Organosol and plastisol coatings shall not be used to bubble emissions from vinyl printing and topcoating.
(5) The emission limitations specified above shall be achieved by:
(a) The application of a low solvent content coating technology; or
(b) Incineration, provided that a minimum of 90 percent of the non-methane [
volatile organic compounds]VOCs (VOCs measured as total combustible carbon) that enter the incinerator are oxidized to carbon dioxide and water; or(c) Through carbon adsorption provided that there is a minimum of 90 percent reduction efficiency of captured VOC emissions.
(6) The design, operation, and efficiency of any capture system used in conjunction with (5) above shall be certified in writing by the owner or operator and approved by the executive secretary.
R307-340-7. Metal Furniture Coating VOC Emissions.
(1) R307-340-7 applies to the application areas, flash-off areas, and ovens of metal furniture coating lines involved in prime and top-coat or single coat operations.
(2) No owner or operator of a metal furniture coating line subject to this section may cause, allow or permit the discharge into the atmosphere of any [
volatile organic compound]VOC in excess of 0.3 kilograms per liter of coating (3.0 pounds per gallon) excluding water and solvents exempt from the definition of [volatile organic compounds]VOC, delivered to the coating applicator from prime and topcoat or single coat operations.(3) Equivalency calculations for coatings shall be performed in units of lbs. VOCs/gallon of solid rather than lbs. VOCs/gallon of coating when determining compliance. The equivalent emission limit is 5.1 lbs. VOCs/gallon solids.
(4) The emission limitation specified above shall be achieved by:
(a) The application of low solvent technology; or
(b) Incineration, provided that a minimum of 90 percent of the non-methane [
volatile organic compounds]VOCs (VOCs measured as total combustible carbon) that enter the incinerator are oxidized to carbon dioxide and water; or(c) using water-borne electrodeposition; or
(d) using water-borne spray, dip or flowcoat; or
(e) using powder; or
(f) using higher solids spray; or
(g) carbon adsorption.
(5) The design, operation, and efficiency of any capture system used in conjunction with (4) above shall be certified in writing by the owner or operator and approved by the executive secretary.
R307-340-8. Large Appliance Surface Coating VOC Emissions.
(1) R307-340-8 applies to application areas flash-off areas and ovens of large appliance coating lines involved in prime, single or top coating operations.
(2) No owner or operator of a large appliance coating line subject to this section may cause, allow or permit the discharge to the atmosphere of any [
volatile organic compounds]VOCs in excess of 0.34 kilograms per liter of coating (2.8 pounds per gallon), excluding water and solvents exempt from the definition of [volatile organic compound]VOC, delivered to the coating applicator from prime, single, or top-coat coating operations.(3) Equivalency calculations for coatings shall be performed in units of lbs. VOCs/gallon of solid rather than lbs. VOCs/gallon of coating when determining compliance. The equivalent emission limit is 4.5 lbs. VOCs/gallon solids.
(4) The emission limitations specified above shall be achieved by:
(a) The application of low solvent content technology; or
(b) Incineration provided 90 percent of the non-methane [
volatile organic compounds]VOCs (VOCs measured as total combustible carbon) that enter the incinerator are oxidized to carbon dioxide and water; or(c) using water-borne electrodeposition; or
(d) using water-borne spray, dip or flowcoat; or
(e) using powder; or
(f) using higher solids spray; or
(g) carbon adsorption.
(5) The design, operation, and efficiency or any capture system used in conjunction with (4) above shall be certified in writing by the owner or operator.
R307-340-9. Magnet Wire Coating VOC Emissions.
(1) R307-340-9 applies to ovens of magnet wire coating operations.
(2) No owner or operator of a magnet wire coating oven subject to this section may cause, allow or permit discharge into the atmosphere of any [
volatile organic compounds]VOCs in excess of 0.20 kilograms per liter of coating (1.7 pounds per gallon), excluding water and solvents exempt from the definition of [volatile organic compound]VOC, delivered to the coating applicator from magnet wire coating operations.(3) Equivalency calculations for coatings shall be performed in units of lbs. VOCs/gallon of solid rather than lbs. VOCs/gallon of coating when determining compliance. The equivalent emission limit is 2.2 lbs. VOCs/gallon solids.
(4) The emission limitations specified above shall be achieved by:
(a) The application of low solvent content coating technology; or
(b) Incineration, provided that a minimum of 90 percent of the non-methane [
volatile organic compounds]VOCs (VOCs measured as total combustible carbon) that enter the incinerator are oxidized to carbon dioxide and water; or(5) The design, operation, and efficiency of any capture system used in conjunction with (4)(b) above shall be certified in writing by the owner or operator and approved by the executive secretary.
R307-340-10. Flat Wood Coating.
(1) R307-340-10 applies to the application areas of flat wood coating operations involved in but not limited to, filler, sealer, groove coat, primer, stain, basecoat, inks, and topcoat operations.
(2) No owner or operator of an interior printed hardwood, plywood, and particle board coating operation may cause, allow or permit discharge to the atmosphere of any [
organic volatile compound]VOCs in excess of a weighted average VOC content of 0.20 kilograms per liter of coating (1.7 pounds per gallon), excluding water and solvents exempt from the definition of [volatile organic compound]VOC, delivered to a coating applicator from, but not limited to, filler, sealer, groove coat, primer, stain, basecoat, ink and topcoat operation.(3) No owner or operator of a natural finish hardwood plywood coating operation may cause, allow or permit discharge to the atmosphere any [
organic volatile compound]VOCs in excess of a weighted average VOC content of 0.40 kilograms per liter of coating (3.3 pounds per gallon) excluding water and solvents exempt from the definition of [volatile organic compound]VOC, delivered to a coating applicator from, but not limited to, filler, sealer, groove coat, primer, stain basecoat, ink and topcoat operations.(4) No owner or operator of a Class II hardwood panel finish operation may cause, allow, or permit discharge to the atmosphere of any [
organic volatile compound]VOCs in excess of a weighted average VOC content of 0.34 kilograms per liter of coating (2.8 pounds per gallon), excluding water and solvents exempt from the definition of [volatile organic compound]VOC, delivered to a coating applicator from, but not limited to, filler, sealer, groove coat, primer, stain, basecoat, ink, and topcoat operations.(5) The emission limitations specified above shall be achieved by:
(a) The application of low solvent technology; or
(b) The application of water-borne coating technology; or
(c) The application of ultraviolet-curable coating technology; or.
(6) This regulation does not apply to the manufacture of exterior siding, tile board, or particle board used as a furniture component.
(7) Equivalency calculations for coatings shall be performed in units of lbs. VOCs/gallon[
s] of solid rather than lbs. VOCs/gallon[s] of coating when determining compliance. The equivalent emission limit for interior printed hardwood, plywood, and particle board coating is 2.2 lbs. VOCs/gallon solids. The equivalent emission limit for natural finish hardwood plywood coating shall be 6.0 lbs. VOCs/gallon solids. The equivalent emission limit for Class II hardwood panel finish operations is 4.5 lbs. VOCs/gallon solids.R307-340-11. Miscellaneous Metal Parts and Products VOC Emissions.
(1) R307-340-11 applies to the application areas, flash-off areas air and forced air dryers, and ovens used in the surface coating of miscellaneous metal parts and products:
(2) Applicable Industries:
(a) Large farm machinery (harvesting, fertilizing, planting, tractors, combines, etc.)
(b) Small farm machinery (lawn and garden tractors, lawn mowers, rototillers, etc.)
(c) Small appliance (fans, mixers, blenders, crock pots, vacuum cleaners, etc.)
(d) Commercial machinery (computers, typewriters, calculators, vending machines, etc.)
(e) Industrial machinery (pumps, compressors, conveyor components, fans, blowers, transformers, etc.)
(f) Fabricated metal products (metal covered doors, frames, trailer frames, etc.)
(g) Any other industrial category that coats metal parts or products under the standard Industrial Classification Code of major group 33 (primary metal industries), major group 34 (fabricated metal products), major group 35 (nonelectric machinery), major group 36 (electrical machinery), major group 37 (transportation equipment) major group 38 (miscellaneous instruments), and major group 39 (miscellaneous manufacturing industries).
(h) This regulation does not apply to:
(i) the surface coating of automobiles and light-duty trucks,
(ii) flat metal sheets and strips in the form of rolls or coils,
(iii) exterior of airplanes,
(iv) automobile refinishing,
(v) exterior of marine vessels,
(vi) customized top coating of automobiles and trucks if production is less than 35 vehicles per day,
(vii) a source whose potential VOC emissions are less than 10 tons/year. Potential emissions are based upon design capacity (or maximum production), and 8760 hours/year, before add-on controls. The potential emission level is determined on a plant-wide basis, summing all individual emission sources within the miscellaneous metal parts and products category.
(3) No owner or operator of a facility engaged in the surface coating of miscellaneous metal parts and products may cause, allow or permit discharge to the atmosphere of any [
volatile organic compounds]VOCs in excess of:(a) 0.52 kilograms per liter (4.3 pounds per gallon) of coating, excluding water and solvents exempt from the definition of [
volatile organic compound]VOC, delivered to a coating applicator that applies clear coating;(b) 0.42 kilograms per liter (3.5 pounds per gallon) of coating, excluding water and solvents exempt from the definition of [
volatile organic compound]VOC, delivered to a coating applicator in a coating application system that utilizes air or forced warm air at temperatures up to 90 degrees C (194 degrees F);(c) 0.42 kilograms per liter (3.5 pounds per gallon) of coating, excluding water and solvents exempt from the definition of [
volatile organic compound]VOC, delivered to a coating applicator that applies extreme performance coatings;(d) 0.36 kilograms per liter (3.0 pounds per gallon) of coating, excluding water and solvents exempt from the definition of [
volatile organic compound]VOC, delivered to a coating applicator for all other coating and coating application systems.(4) Equivalency calculations for coatings shall be performed in units of lbs. VOCs/gallon of solid rather than lbs. VOCs/gallon of coating when determining compliance. The equivalent emission limit for air dried items is 6.7 lbs. VOCs/gallon solids. The equivalent emission limit for clear-coated items is 10.3 lbs. VOCs/gallon solids. The equivalent emission limit for extreme performance coatings is 6.7 lbs. VOCs/gallon solids. The equivalent emission limit for other coatings and systems is 5.1 lbs. VOCs/gallon solids.
(5) If more than one emission limitation indicated in this section applies to a specific coating, then the least stringent emission limitation shall apply. All [
volatile organic compound]VOC emissions from solvent washing involved in a coating process shall be considered in the emission limitations set forth in R307-340-11(3), unless the solvent is directed into containers that prevent evaporation into the atmosphere.(6) The emission limitations set forth in (3) above shall be achieved by:
(a) The application of low solvent technology; or
(b) An incineration system that oxidizes a minimum of 90 percent of the non-methane [
volatile organic compounds]VOCs (VOCs measure[s]d as total combustible carbon) to carbon dioxide and water.(7) The design, operation, and efficiency of any capture system used in conjunction with (6)(b) above shall be certified in writing by the owner or operator and approved by the executive secretary.
R307-340-12. Graphic Arts.
(1) R307-340-12 applies to: packaging and publication rotogravure; packaging and publication flexographic; and specialty printing operations employing solvents containing ink and having plant-wide potential emissions of [
volatile organic compounds(]VOCs[)] equal to or greater than 90 megagrams/yr (100 tons/yr). Potential emissions shall be calculated based on uncontrolled emissions operating at design capacity or at maximum production for 8760 hours/year. (Solvent shall include that used for dilution of ink and for equipment cleaning.) Machines that have both coating units (application of a uniform layer of material across the entire width of a web) and printing units (formation of words, designs and pictures) shall be considered as performing a printing operation. This rule does not apply to offset lithography or letter press printing that do not use [volatile organic compounds]VOCs.(2) No owner or operator of a packaging and publication rotogravure; packaging and publication flexographic, and specialty printing operations employing solvent containing ink may operate, cause, or allow or permit the operation of a facility unless:
(a) The volatile fraction of ink, as it is applied to the substrate, contains 25.0 percent by volume or less of organic solvent and 75.0 percent by volume or more of water; or
(b) The ink as it is applies to the substrate, less water, contains 60.0 percent by volume or more nonvolatile material; or
(c) The owner or operator installs and operates;
(i) A carbon adsorption system that reduces the volatile organic emissions from the capture system by a minimum of 90.0 percent by weight; or
(ii) An incineration system that oxidizes a minimum of 90.0 percent of the non-methane [
volatile organic compounds (]VOCs measured as total combustible carbon) to carbon dioxide and water.(3) A capture system must be used in conjunction with the emission control systems indicated in this section. The design and operation of a capture system must be consistent with good engineering practices and shall be required to provide for an overall reduction in [
volatile organic compound]VOC emissions of at least:(a) 75.0 percent where a publication rotogravure process is employed;
(b) 65.0 percent where a packaging rotogravure process is employed; or
(c) 60.0 percent where a flexographic printing process is employed.
R307-340-13. Exemptions.
The requirements of R307-340-3 through 10 shall not apply to the following:
(1) sources whose emissions of [
volatile organic compounds]VOCs are not more than 6.8 kilograms (15 pounds) in any 24 hour period, nor more than 1.4 kilograms (3 pounds) in any one (1) hour provided the emission rates are certified. These cutoffs apply to the emissions level on a plant-wide basis, and are determined by summing emissions from all coating operations within the same regulated category;(2) sources used exclusively for chemical or physical analysis or determination of product quality and commercial acceptance provided;
(a) the operation of the source is not an integral part of the production process; and
(b) the emissions from the source do not exceed 363 kilograms (800 pounds) in any one calendar month. These cutoffs apply to the emissions level on a plant-wide basis, and are determined by summing emissions from all coating operations within the same regulated category.
. . . . . . .
R307-340-15. Testing and Monitoring.
(1) Upon request by the executive secretary, the owner or operator of a [
volatile organic compound]VOC source required to comply with R307-340 shall demonstrate compliance by the method of this section or an alternative method approved by the executive secretary.(2) Test procedures to determine compliance with R307-340 must be approved by the executive secretary and must utilize one of the following methods or an alternative method approved by the executive secretary or equivalent method.
(a) For surface coatings: EPA Reference Method 24 of 40 CFR Part 60
(b) For add-on control equipment: EPA Reference Methods 1 through 4, 18 and 25, of the 40 CFR Part 60;
(c) EPA 340/1-86-016 "A Guide for Surface Coating Calculations;" and
(d) EPA 450/3-84-019 "Procedures for Certifying Quantity of [
Volatile organic Compounds]VOCs Emitted by Paint, Ink and Other Coatings."(3) All tests shall be made by, or under the direction of, a person qualified by training or experience, or both, in the field of air pollution testing. The executive secretary will evaluate test data submitted.
(4) A person proposing to conduct a [
volatile organic compound]VOC emissions test shall notify the executive secretary of the intent to test not less than 30 days before the proposed initiation of the test. The notification shall contain the information required by, and be in a format approved by, the executive secretary.(5) If add-on control equipment is used, continuous monitors of the following parameters shall be installed, periodically calibrated, and operated at all times that the associated control equipment is operating:
(a) Exhaust gas temperatures of all incinerators;
(b) Temperature rise across a catalytic incinerator bed;
(c) Breakthrough of VOCs on a carbon adsorption unit; and
(d) Any other continuous monitoring or recording device required by the executive secretary.
(6) The executive secretary may accept, instead of the testing required in R307-340-15, a certification by the manufacturer of the composition of the coatings if supported by actual batch formulation records. The owner or operator of a VOC source required to comply with R307-340 must obtain certification from the coating manufacturers that the test methods used for determination of the VOC content meet the requirements specified in (2) above. The owner or operator shall make this certification readily available to the Division of Air Quality to allow the results to be used in the daily compliance calculations specified in R307-340-4(5).
(7) The performance of add-on control equipment shall be demonstrated with the required test methods of (2) above at equipment start up and after any major modification to the control equipment. Baseline operating parameters shall be established during the satisfactory (i.e. in-compliance) operation of the control equipment, including operation during all anticipated ranges of process throughput. During subsequent process operation, the owner or operator shall maintain the operating conditions of the add-on controls as close to these baseline conditions as possible. If serious operational problems with an add-on control system are indicated by the daily monitoring required by R307-340-4(2)(d), (such problems may be indicated by changes from baseline conditions), repeat performance tests shall be performed by the owner or operator, and may be required by the executive secretary, as necessary.
(8) To determine compliance with the applicable standards in R307-340, samples shall be taken from the coating as freshly delivered to the reservoir of the coating applicator. All VOC emissions from solvent washing involved in a coating process shall be considered in determining compliance with an emission limit, unless the source owner or operator documents that the VOCs from solvent washing are collected and disposed of in a manner that prevents their evaporation into the atmosphere.
. . . . . . .
KEY: air pollution, emission controls, surface coating, ozone
Date of Enactment or Last Substantive Amendment: [
2006]2007Notice of Continuation: August 5, 2003
Authorizing, and Implemented or Interpreted Law: 19-2-104(1)(a)
Document Information
- Effective Date:
- 3/6/2007
- Publication Date:
- 02/01/2007
- Filed Date:
- 01/12/2007
- Agencies:
- Environmental Quality,Air Quality
- Rulemaking Authority:
Subsection 19-2-104(1)(a)
- Authorized By:
- M. Cheryl Heying, Planning Branch Manager
- DAR File No.:
- 29009
- Related Chapter/Rule NO.: (1)
- R307-340. Davis and Salt Lake Counties and Ozone Nonattainment Areas: Surface Coating Processes.