No. 32001 (Amendment): R156-56. Utah Uniform Building Standard Act Rules  

  • DAR File No.: 32001
    Filed: 10/06/2008, 07:51
    Received by: NL

    RULE ANALYSIS

    Purpose of the rule or reason for the change:

    The Division is proposing changes to the rule to adopt amendments to the building codes approved by the Uniform Building Code Commission after review by various subcommittees.

    Summary of the rule or change:

    In Section R156-56-401, adds a three-digit alphabetical character for Apple Valley since they are now issuing their own building permits instead of having Washington County issue them. In Subsection R156-56-801(18), a current state amendment which requires elevator lobbies in certain buildings is being deleted. Deleting the current amendment to the International Building Code (IBC) will give a building owner the option to design and build a building that is between four and seven floors high without an elevator lobby provided all other requirements are met. The remaining subsections in this section have been renumbered.

    State statutory or constitutional authorization for this rule:

    Sections 58-56-1 and 58-56-19, and Subsections 58-1-106(1)(a), 58-5-202(1)(a), 58-56-4(2), and 58-56-6(2)(a)

    Anticipated cost or savings to:

    the state budget:

    The Division has determined that there should be no direct effect on the state budget as a result of the proposed amendments. However, there may be an indirect effect on the state budget when the state is involved in construction projects that meet the criteria and it could result in potential savings.

    local governments:

    The Division has determined that there should be no direct effect on local governments as a result of the proposed amendments. However, there may be an indirect effect on local governments when a local government is involved in construction projects that meet the criteria and it could result in potential savings.

    small businesses and persons other than businesses:

    Adding the three-digit alphabetical character for Apple Valley for a standardized building permit will not affect the cost to any party. It just reflects which local compliance agency is issuing the building permit. There is a potential cost savings to affected parties, which may include a small business, who would choose to design and build a building without an elevator lobby. It is impossible for the Division to determine an aggregate impact because of the variable number of persons this would affect and the variable savings that each builder may experience.

    Compliance costs for affected persons:

    The Division does not anticipate any additional costs to affected parties as a result of these proposed amendments. There may be savings of up to several thousands of dollars for persons who design and build buildings between four and seven floors in height. It is impossible for the Division to estimate the number of persons who may be affected by these proposed amendments.

    Comments by the department head on the fiscal impact the rule may have on businesses:

    The fiscal impact to businesses anticipated from this rule filing is a savings to builders who no longer would be required to include an elevator lobby in buildings with four to seven stories. The amount of the savings depends on the building at issue. Francine A. Giani, Executive Director

    The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:

    Commerce
    Occupational and Professional Licensing
    HEBER M WELLS BLDG
    160 E 300 S
    SALT LAKE CITY UT 84111-2316

    Direct questions regarding this rule to:

    Dan S. Jones at the above address, by phone at 801-530-6720, by FAX at 801-530-6511, or by Internet E-mail at dansjones@utah.gov

    Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

    12/01/2008

    Interested persons may attend a public hearing regarding this rule:

    11/17/2008 at 9:00 AM, State Office Building, 450 N State St, Room 4112, Salt Lake City, UT

    This rule may become effective on:

    12/08/2008

    Authorized by:

    F. David Stanley, Director

    RULE TEXT

    R156. Commerce, Occupational and Professional Licensing.

    R156-56. Utah Uniform Building Standard Act Rules.

    R156-56-401. Standardized Building Permit Number.

    As provided in Section 58-56-19, beginning on January 1, 2007, any agency issuing a permit for construction within the state of Utah shall use the standardized building permit numbering which includes the following:

    (1) The permit number shall consist of 12 digits with the following components in the following order:

    (a) digits one, two and three shall be alphabetical characters identifying the compliance agency issuing the permit as specified in the table in Subsection (3);

    (b) digits four and five shall be numerical characters indicating the year of permit issuance;

    (c) digits six and seven shall be numerical characters indicating the month of permit issuance;

    (d) digits eight and nine shall be numerical characters indicating the day of the month on which the permit is issued; and

    (e) digits ten, eleven and twelve shall be numerical characters used to distinguish between permits issued by the agency on the same day.

    (2) When used in addition to a different permit numbering system, as provided for in Subsection 58-56-19(3)(b), the standardized building permit number shall be clearly identified and labeled as the "state permit number" or "Utah permit number".

    (3) The following table establishes the three digit alphabetical character for which the compliance agency shall be identified as provided in Subsection (1)(a):

     

    TABLE
    COMPLIANCE AGENCY PERMIT TABLE
    FOR STANDARDIZED BUILDING PERMIT
    THREE LETTER DESIGNATIONS


    Index:
    Column 1: City, town, or other compliance agency in
    which project is located
    Column 2: County in which the city, town, or other
    compliance agency is located
    Column 3: City, town or other compliance agency
    3 digit designation (Designation is shown for cities,
    towns, or other compliance agency which issue
    building permits. If no designation is shown, the
    building permits for the city, town, or other
    compliance agency are issued by the county, therefore
    the county three digit designation should be used)
    Column 4: County 3 digit designation


    1 2 3 4
    City, Town, County City, Town, County[or]
    or other or other Designa-
    Compliance Agency Compliance tion
    Agency
    Designation
    Adamsville BEAVER BVR
    Alpine UTAH ALP
    Alta SALT LAKE ALT
    Altamont DUCHESNE DCH
    Alton KANE KAN
    Altonah DUCHESNE DCH
    Amalga CACHE CAC
    American Fork UTAH AFC
    Aneth SAN JUAN SJC
    Angle PIUTE PIU
    Annabella SEVIER SEV
    Antimony GARFIELD GRF
    Apple Valley WASHINGTON AVC[ WSC]
    Aragonite TOOELE TOC
    Aurora SEVIER SEV
    Austin SEVIER SEV
    Avon CACHE CAC
    Axtell SANPETE SPC
    Bacchus SALT LAKE SCO
    Ballard UINTAH BAL
    Bauer TOOELE TOC
    Bear River BOX ELDER BRC
    Beaver City BEAVER BEA
    BEAVER COUNTY BVR
    Beaver Dam BOX ELDER BEC
    Benjamin UTAH UTA
    Benson CACHE CAC
    Beryl IRON IRO
    Bicknell WAYNE WAY
    Big Water KANE BWM
    Birdseye UTAH UTA
    Black Rock MILLARD MIL
    Blanding SAN JUAN BLA
    Bloomington Hills WASHINGTON STG (part of St.
    George)
    Bloomington WASHINGTON STG (part of St.
    George)
    Blue Creek BOX ELDER BEC
    Bluebell DUCHESNE DCH
    Bluff SAN JUAN SJC
    Bluffdale SALT LAKE BLU
    Bonanza UINTAH UTC
    Boneta DUCHESNE DCH
    Bothwell BOX ELDER BEC
    Boulder GARFIELD GRF
    Bountiful DAVIS BOU
    BOX ELDER COUNTY BEC
    Brian Head IRON BHT
    Bridgeland DUCHESNE DCH
    Brigham BOX ELDER BRI
    Brighton SALT LAKE SCO
    Brookside WASHINGTON WSC
    Bryce GARFIELD GRF
    Bullfrog KANE KAN
    Burmester TOOELE TOC
    Burrville SEVIER SEV
    CACHE COUNTY CAC
    Cache Junction CACHE CAC
    Caineville WAYNE WAY
    Callao JUAB JUA
    Camp Williams UTAH UTA
    Cannonville GARFIELD GRF
    CARBON COUNTY CAR
    Carbonville CARBON CAR
    Castle Dale EMERY EMR
    Castle Rock SUMMIT SUM
    Castle Valley GRAND GRA
    Cedar City IRON CEC
    Cedar Creek BOX ELDER BEC
    Cedar Fort UTAH CFT
    Cedar Hills UTAH CDH
    Cedar Mountain TOOELE TOC
    Cedar Springs BOX ELDER BEC
    Cedar Valley UTAH UTA
    Cedarview DUCHESNE DCH
    Center Creek WASATCH WAC
    Centerfield SANPETE SPC
    Centerville DAVIS CEV
    Central SEVIER SEV
    Central WASHINGTON WSC
    Central Valley SEVIER SEV
    Charleston WASATCH CHA
    Chester SANPETE SPC
    Christinburg SANPETE SPC
    Christmas Meadows SUMMIT SUM
    Church Wells KANE KAN
    Circleville PIUTE CIR
    Cisco GRAND GRA
    Clarkston CACHE CAC
    Clawson EMERY EMR
    Clear Lake MILLARD MIL
    Clearcreek BOX ELDER BEC
    Clearcreek CARBON CAR
    Clearfield DAVIS CLE
    Cleveland EMERY EMR
    Clinton DAVIS CLI
    Clive TOOELE TOC
    Clover TOOELE RUV(became Rush
    Valley)
    Coalville SUMMIT COA
    College Ward CACHE CAC
    Collinston BOX ELDER BEC
    Colton UTAH UTA
    Copperton SALT LAKE SCO
    Corinne BOX ELDER COR
    Cornish CACHE CAC
    Cottonwood SALT LAKE SCO
    Cottonwood Heights SALT LAKE CHC
    Cove CACHE CAC
    Cove Fort MILLARD MIL
    Crescent SALT LAKE SCO
    Crescent Junction GRAND GRA
    Croyden MORGAN MRG
    DAGGETT COUNTY DAG
    Dameron Valley WASHINGTON WSC
    Daniels WASATCH DAN
    DAVIS COUNTY DAV
    Deer Creek WASATCH WAC
    Delle TOOELE TOC
    Delta MILLARD DEL
    Deseret MILLARD MIL
    Deseret Mound IRON IRO
    Devils Slide MORGAN MRG
    Deweyville BOX ELDER DEW
    Diamond Valley WASHINGTON WSC
    Div of Facilities
    Construction and Mgmt (statewide) FCM
    Dividend UTAH UTA
    Draper SALT LAKE DRA
    Draper City South UTAH UTA
    Duchesne City DUCHESNE DUC
    DUCHESNE COUNTY DCH
    Duck Creek KANE KAN
    Dugway (Federal) TOOELE XXX
    Dutch John DAGGETT DAG
    Eagle Mountain UTAH EMC
    East Carbon CARBON ECC
    East Green River GRAND GRA
    East Millcreek SALT LAKE SCO
    Eastland SAN JUAN SJC
    Echo SUMMIT SUM
    Eden WEBER WEB
    Elk Ridge UTAH ERC
    Elberta UTAH UTA
    Elmo EMERY EMR
    Elsinore SEVIER SEV
    Elwood BOX ELDER ELW
    Emery City EMERY EME
    EMERY COUNTY EMR
    Emory SUMMIT SUM
    Enoch IRON ENO
    Enterprise WASHINGTON ENT
    Ephraim SANPETE SPC
    Erda TOOELE TOC
    Escalante GARFIELD GRF
    Eskdale MILLARD MIL
    Etna BOX ELDER BEC
    Eureka JUAB EUR
    Fairfield UTAH UTA
    Fairmont SEVIER SEV
    Fairview SANPETE SPC
    Farmington DAVIS FAR
    Farr West WEBER FAW
    Faust TOOELE TOC
    Fayette SANPETE SPC
    Ferron EMERY EMR
    Fielding BOX ELDER FIE
    Fillmore MILLARD FIL
    Flowell MILLARD MIL
    Fort Duchesne UINTAH UTC
    Fountain Green SANPETE SPC
    Francis SUMMIT FRA
    Freedom SANPETE SPC
    Freeport Circle DAVIS DAV
    Fremont WAYNE WAY
    Fremont Junction SEVIER SEV
    Fruit Heights DAVIS FRU
    Fruitland DUCHESNE DCH
    Fry Canyon SAN JUAN SJC
    Gandy MILLARD MIL
    Garden City RICH GAR
    Garfield SALT LAKE SCO
    GARFIELD COUNTY GRF
    Garland BOX ELDER GRL
    Garrison MILLARD MIL
    Geneva UTAH GEV
    Genola UTAH GEN
    Glendale KANE KAN
    Glenwood SEVIER SEV
    Goldhill TOOELE TOC
    Goshen UTAH GOS
    Grafton WASHINGTON ROC (part of Rock-
    ville)
    GRAND COUNTY GRA
    Granite SALT LAKE SCO
    Grantsville TOOELE GTV
    Green River EMERY EMR
    Greenville BEAVER BVR
    Greenwich PIUTE PIU
    Greenwood MILLARD MIL
    Grouse Creek BOX ELDER BEC
    Grover WAYNE WAY
    Gunlock WASHINGTON WSC
    Gunnison SANPETE SPC
    Gusher UINTAH UTC
    Hailstone WASATCH WAC
    Halls Crossing SAN JUAN SJC
    Hamilton Fort IRON IRO
    Hamlin Valley IRON IRO
    Hanksville WAYNE WAY
    Hanna DUCHESNE DCH
    Harrisville WEBER HAR
    Hatch GARFIELD GRF
    Hatton MILLARD MIL
    Heber WASTACH HEB
    Helper CARBON CAR
    Henefer SUMMIT HEN
    Henrieville GARFIELD GRF
    Herriman SALT LAKE HER
    Hiawatha CARBON CAR
    Hideway Valley SANPETE SPC
    Highland UTAH HIG
    Hildale WASHINGTON HIL
    Hinckley MILLARD HIN
    Hite SAN JUAN SJC
    Holden MILLARD HOL
    Holladay SALT LAKE HOD
    Honeyville BOX ELDER HON
    Hooper WEBER HOO
    Hot Springs BOX ELDER BEC
    Hovenweep Mountain SAN JUAN SJC
    Howell BOX ELDER HPW
    Hoytsville SUMMIT SUM
    Huntington EMERY EMR
    Huntsville WEBER HTV
    Hurricane WASHINGTON HUR
    Hyde Park CACHE HPC
    Hyrum CACHE CAC
    Ibapah TOOELE TOC
    Indianola SANPETE SPC
    Ioka DUCHESNE DCH
    IRON COUNTY IRO
    Iron Springs IRON IRO
    Ivins WASHINGTON INI
    Jensen UINTAH UTC
    Jericho JUAB JUA
    Joseph SEVIER SEV
    JUAB COUNTY JUA
    Junction PIUTE JUN
    Kamas SUMMIT KAM
    Kanab KANE KNB
    Kanarraville IRON IRO
    KANE COUNTY KAN
    Kaneville WEBER WEC
    Kanosh MILLARD KNS
    Kayenta WASHINGTON INI (part of Ivins)
    Kaysville DAVIS KAY
    Kearns SALT LAKE SCO
    Keetley WASATCH WAC
    Kelton BOX ELDER BEC
    Kenilworth CARBON CAR
    Kingston PIUTE KIN
    Knolls TOOELE TOC
    Koosharem SEVIER SEV
    La Sal SAN JUAN SJC
    La Verkin WASHINGTON LAV
    Lake Powell SAN JUAN SJC
    Lakepoint TOOELE TOC
    Lakeshore UTAH UTA
    Lakeside BOX ELDER BEC
    Laketown RICH RIC
    Lakeview UTAH UTA
    Lapoint UINTAH UTC
    Lark SALT LAKE SCO
    Lawrence EMERY EMR
    Layton DAVIS LAY
    Leamington MILLARD LEA
    Leeds WASHINGTON LEE
    Leeton UINTAH UTC
    Lehi UTAH LEH
    Leland UTAH UTA
    Leota UINTAH UTC
    Levan JUAB LEV
    Lewiston CACHE LEW
    Liberty WEBER WEC
    Lincoln TOOELE TOC
    Lindon UTAH LIN
    Little Mountain WEBER WEC
    Littleton MORGAN MRG
    Loa WAYNE LOA
    Logan CACHE LOG
    Long Valley KANE KAN
    Losepa TOOELE TOC
    Low TOOELE TOC
    Lucin BOX ELDER BEC
    Lund IRON IRO
    Lyman WAYNE WAY
    Lynn BOX ELDER BEC
    Lynndyl MILLARD LYN
    Madsen BOX ELDER BEC
    Maeser UINTAH UTC
    Magna SALT LAKE SCO
    Mammoth JUAB JUA
    Manderfield BEAVER BVR
    Manila DAGGETT MNL
    Manti SANPETE SPC
    Mantua BOX ELDER MNT
    Mapleton UTAH MAP
    Marion SUMMIT SUM
    Marriott-Slaterville WEBER MSC
    Marysvale PIUTE MAR
    Mayfield SANPETE SPC
    Meadow MILLARD MEA
    Meadowville RICH RIC
    Mendon CACHE MEN
    Mexican Hat SAN JUAN SJC
    Middleton WASHINGTON STG (part of St.
    George)
    Midvale SALT LAKE MID
    Midway WASATCH MWC
    Milburn SANPETE SPC
    Milford BEAVER MLF
    Mill Fork UTAH UTA
    MILLARD COUNTY MIL
    Mills JUAB JUA
    Mills Junction TOOELE TOC
    Millville CACHE CAC
    Milton MORGAN MRG
    Minersville BEAVER BVR
    Moab GRAND MOA
    Modena IRON IRO
    Mohrland EMERY EMR
    Molen EMERY EMR
    Mona JUAB MON
    Monarch DUCHESNE DCH
    Monroe SEVIER SEV
    Montezuma Creek SAN JUAN SJC
    Monticello SAN JUAN MNC
    Monument Valley SAN JUAN SJC
    Moore EMERY EMR
    Morgan City MORGAN MOR
    MORGAN COUNTY MRG
    Moroni SANPETE SPC
    Mt Carmel KANE KAN
    Mt Emmons DUCHESNE DCH
    Mt Green MORGAN MRG
    Mt Home DUCHESNE DCH
    Mt Olympus SALT LAKE SCO
    Mt Pleasant SANPETE SPC
    Mt Sterling CACHE CAC
    Murray SALT LAKE MUR
    Myton DUCHESNE DCH
    Naples UINTAH NAP
    National CARBON CAR
    Navaho Lake DUCHESNE DCH
    Neola DUCHESNE DCH
    Nephi JUAB NEP
    New Harmony WASHINGTON WSC
    Newcastle IRON IRO
    Newton CACHE NEW
    Nibley CACHE NIB
    North Logan CACHE NLC
    North Ogden WEBER NOC
    North Salt Lake DAVIS NSL
    Oak City MILLARD OAK
    Oakley SUMMIT OKL
    Oasis MILLARD MIL
    Ogden WEBER OGD
    Ogden City School Dist WEBER OSD
    Ophir TOOELE OPH
    Orangeville EMERY ORA
    Orderville KANE KAN
    Orem UTAH ORE
    Orrey WAYNE WAY
    Ouray UINTAH UTC
    Palmyra UTAH UTA
    Panguitch GARFIELD GRF
    Paradise CACHE CAC
    Paragonah IRON IRO
    Park City SUMMIT PAC
    Park City East WASATCH WAC
    Park Valley BOX ELDER BEC
    Parowan IRON IRO
    Partoun JUAB JUA
    Payson UTAH PAY
    Penrose BOX ELDER BEC
    Peoa SUMMIT SUM
    Perry BOX ELDER PER
    Petersboro CACHE CAC
    Peterson MORGAN MRG
    Pickleville RICH RIC
    Pigeon Hollow Junction SANPETE SPC
    Pine Valley WASHINGTON WSC
    Pineview SUMMIT SUM
    Pinto WASHINGTON WSC
    Pintura WASHINGTON WSC
    PIUTE COUNTY PIU
    Plain City WEBER PLA
    Pleasant Grove UTAH PGC
    Pleasant View WEBER PVC
    Plymouth BOX ELDER PLY
    Portage BOX ELDER BEC
    Porterville MORGAN MRG
    Price CARBON PRI
    Promontory BOX ELDER BEC
    Providence CACHE PRV
    Provo UTAH PRO
    Provo Canyon UTAH UTA
    Randlett UINTAH UTC
    Randolph RICH RAN
    Redmond SEVIER RED
    Redmonton BOX ELDER BEC
    RICH COUNTY RIC
    Richfield SEVIER RCF
    Richmond CACHE CAC
    Richville MORGAN MRG
    River Heights CACHE CAC
    Riverdale WEBER RVD
    Riverside BOX ELDER BEC
    Riverton SALT LAKE RVT
    Rockville WASHINGTON ROC
    Rocky Ridge Town JUAB ROR
    Roosevelt DUCHESNE ROO
    Rosette BOX ELDER BEC
    Round Valley RICH RIC
    Roy WEBER ROY
    Rubys Inn GARFIELD GRF
    Rush Valley TOOELE RUV
    Sage Creek Junction RICH RIC
    Salem UTAH SLM
    Salina SEVIER SEV
    Salt Lake City SALT LAKE SLC
    SALT LAKE COUNTY SCO
    Salt Lake Suburban
    Sanitary District #1 SALT LAKE SSD
    Salt Springs TOOELE TOC
    Samak SUMMIT SUM
    SAN JUAN COUNTY SJC
    Sandy SALT LAKE SAN
    SANPETE COUNTY SPC
    Santa Clara WASHINGTON SAC
    Santaquin UTAH STQ
    Saratoga Springs UTAH SRT
    Scipio MILLARD SCI
    Scofield CARBON CAR
    Sevier SEVIER SEV
    SEVIER COUNTY SEV
    Shivwits (Federal) WASHINGTON YYY
    Sigurd SEVIER SEV
    Silver City JUAB JUA
    Silver Creek Junction SUMMIT SUM
    Silver Fork SALT LAKE SCO
    Silver Reef WASHINGTON LEE (part of Leeds)
    Smithfield CACHE SMI
    Snowbird SALT LAKE SCO
    Snowville BOX ELDER SNO
    Snyderville SUMMIT SUM
    Soldier Summit WASATCH WAC
    South Jordan SALT LAKE SOJ
    South Ogden WEBER SOO
    South Salt Lake SALT LAKE SSL
    South Weber DAVIS SWC
    Spanish Fork UTAH SFC
    Spring City SANPETE SPC
    Spring Glen CARBON CAR
    Spring Lake UTAH UTA
    Springdale WASHINGTON SPD
    Springville UTAH SPV
    St George WASHINGTON STG
    St John TOOELE RUV (became Rush
    Valley)
    Standrod BOX ELDER BEC
    Stansbury Park TOOELE TOC
    Sterling SANPETE SPC
    Stockmore DUCHESNE DCH
    Stockton TOOELE STO
    Stoddard MORGAN MRG
    Sugarville MILLARD MIL
    Summit IRON IRO
    SUMMIT COUNTY SUM
    Summit Park SUMMIT SUM
    Summit Point SAN JUAN SJC
    Sundance UTAH UTA
    Sunnyside CARBON CAR
    Sunset DAVIS SUN
    Sutherland MILLARD MIL
    Swan Creek TOOELE TOC
    Syracuse DAVIS SYR
    Tabiona DUCHESNE DCH
    Talmage DUCHESNE DCH
    Taylor WEBER WEC
    Taylorsville SALT LAKE TAY
    Teasdale WAYNE WAY
    Thatcher BOX ELDER THA
    Thistle UTAH UTA
    Thompson Springs GRAND GRA
    Ticaboo GARFIELD GRF
    Timpe TOOELE TOC
    Tintic JUAB JUA
    Tooele City TOOELE TOO
    TOOELE COUNTY TOC
    Toquerville WASHINGTON TOQ
    Torrey WAYNE WAY
    Tremonton BOX ELDER TRE
    Trenton CACHE CAC
    Tridell UINTAH UTC
    Tropic GARFIELD GRF
    Trout Creek JUAB JUA
    Tucker UTAH UTA
    Ucolo SAN JUAN SJC
    Uintah WEBER UIN
    UINTAH COUNTY UTC
    Upalco DUCHESNE DCH
    Upton SUMMIT SUM
    UTAH COUNTY UTA
    Uvada IRON IRO
    Venice SEVIER SEV
    Vernal UINTAH VER
    Vernon TOOELE TOC
    Veyo WASHINGTON WSC
    Vineyard UTAH VIN
    Virgin WASHINGTON VIR
    Wahsatch SUMMIT SUM
    Wales SANPETE SPC
    Wallsburg WASATCH WAC
    Wanship SUMMIT SUM
    Warren WEBER WEC
    WASATCH COUNTY WAC
    Washington City WASHINGTON WAS
    Washakie BOX ELDER BEC
    Washington Terrace WEBER WAT
    WASHINGTON COUNTY WSC
    WAYNE COUNTY WAY
    WEBER COUNTY WEC
    Webster Cove Junction CACHE CAC
    Wellington CARBON CAR
    Wellsville CACHE CAC
    Wendover TOOELE WEN
    West Bountiful DAVIS WEB
    West Haven WEBER WEH
    West Jordan SALT LAKE WEJ
    West Point DAVIS WEP
    West Valley SALT LAKE WVC
    West Warren WEBER WEC
    West Weber WEBER WEC
    Westwater GRAND GRA
    Whiterocks UINTAH UTC
    Widtsoe Junction GARFIELD GRF
    Wildwood UTAH UTA
    Willard BOX ELDER WIL
    Wilson WEBER WEC
    Wins WASHINGTON WSC
    Woodland Hills UTAH WHO
    Woodland SUMMIT SUM
    Woodruff RICH RIC
    Woodrow MILLARD MIL
    Woods Cross DAVIS WXC
    Woodside EMERY EMR
    Yost BOX ELDER BEC
    Young Ward CACHE CAC
    Zane IRON IRO

     

    R156-56-801. Statewide Amendments to the IBC.

    The following are adopted as amendments to the IBC to be applicable statewide:

    (1) All references to the ICC Electrical Code are deleted and replaced with the National Electrical Code adopted under Subsection R156-56-701(1)(b).

    (2) Section 101.4.1 is deleted and replaced with the following:

    101.4.1 Electrical. The provisions of the National Electrical Code (NEC) shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto.

    (3) Section 106.3.2 is deleted and replaced with the following:

    106.3.2 Previous approval. If a lawful permit has been issued and the construction of which has been pursued in good faith within 180 days after the effective date of the code and has not been abandoned, then the construction may be completed under the code in effect at the time of the issuance of the permit.

    (4) In Section 109, a new section is added as follows:

    109.3.5 Weather-resistive barrier and flashing. An inspection shall be made of the weather-resistive barrier as required by Section 1403.2 and flashing as required by Section 1405.3 to prevent water from entering the weather-resistant exterior wall envelope.

    The remaining sections will be renumbered as follows:

    109.3.6 Lath or gypsum board inspection

    109.3.7 Fire-resistant penetrations

    109.3.8 Energy efficiency inspections

    109.3.9 Other inspections

    109.3.10 Special inspections

    109.3.11 Final inspection.

    (5) Section 114.1 is deleted and replaced with the following:

    114.1 Authority. Whenever the building official finds any work regulated by this code being performed in a manner either contrary to the provisions of this code or other pertinent laws or ordinances or dangerous or unsafe, the building official is authorized to stop work.

    (6) In Section 202, the definition for Assisted Living Facility is deleted and replaced with the following:

    ASSISTED LIVING FACILITY. See Section 308.1.1.

    (7) Section 305.2 is deleted and replaced with the following:

    305.2 Day care. The building or structure, or portion thereof, for educational, supervision, child day care centers, or personal care services of more than four children shall be classified as a Group E occupancy. See Section 421 for special requirements for Group E child day care centers.

    Exception: Areas used for child day care purposes with a Residential Certificate, Family License or Family Group License may be located in a Group R-2 or R-3 occupancy as provided in Section 310.1 or shall comply with the International Residential Code in accordance with Section 101.2.

    Child day care centers providing care for more than 100 children 2 1/2 years or less of age shall be classified as Group I-4.

    (8) In Section 308 the following definitions are added:

    308.1.1 Definitions. The following words and terms shall, for the purposes of this section and as used elsewhere in this code, have the meanings shown herein.

    TYPE I ASSISTED LIVING FACILITY. A residential facility licensed by the Utah Department of Health that provides a protected living arrangement for ambulatory, non-restrained persons who are capable of achieving mobility sufficient to exit the facility without the assistance of another person.

    TYPE II ASSISTED LIVING FACILITY. A residential facility licensed by the Utah Department of Health that provides an array of coordinated supportive personal and health care services to residents who meet the definition of semi-independent.

    SEMI-INDEPENDENT. A person who is:

    A. Physically disabled but able to direct his or her own care; or

    B. Cognitively impaired or physically disabled but able to evacuate from the facility with the physical assistance of one person.

    RESIDENTIAL TREATMENT/SUPPORT ASSISTED LIVING FACILITY. A residential treatment/support assisted living facility which creates a group living environment for four or more residents licensed by the Utah Department of Human Services, and provides a protected living arrangement for ambulatory, non-restrained persons who are capable of achieving mobility sufficient to exit the facility without the physical assistance of another person.

    (9) Section 308.2 is deleted and replaced with the following:

    308.2 Group I-1. This occupancy shall include buildings, structures, or parts thereof housing more than 16 persons, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment that provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. This group shall include, but not be limited to, the following: residential board and care facilities, type I assisted living facilities, residential treatment/support assisted living facility, half-way houses, group homes, congregate care facilities, social rehabilitation facilities, alcohol and drug centers and convalescent facilities. A facility such as the above with five or fewer persons shall be classified as a Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2. A facility such as above, housing at least six and not more than 16 persons, shall be classified as a Group R-4.

    (10) Section 308.3 is deleted and replaced with the following:

    308.3 Group I-2. This occupancy shall include buildings and structures used for medical, surgical, psychiatric, nursing or custodial care on a 24-hour basis of more than three persons who are not capable of self-preservation. This group shall include, but not be limited to the following: hospitals, nursing homes (both intermediate care facilities and skilled nursing facilities), mental hospitals, detoxification facilities, ambulatory surgical centers with two or more operating rooms where care is less than 24 hours, outpatient medical care facilities for ambulatory patients (accommodating more than five such patients in each tenant space) which may render the patient incapable of unassisted self-preservation, and type II assisted living facilities. Type II assisted living facilities with five or fewer persons shall be classified as a Group R-4. Type II assisted living facilities as defined in 308.1.1 with at least six and not more than sixteen residents shall be classified as a Group I-1 facility.

    (11) Section 308.3.1 is deleted and replaced with the following:

    308.3.1 Child care facility. A child care facility that provides care on a 24 hour basis to more than four children 2 1/2 years of age or less shall be classified as Group I-2.

    (12) Section 308.5 is deleted and replaced with the following:

    308.5 Group I-4, day care facilities. This group shall include buildings and structures occupied by persons of any age who receive custodial care less than 24 hours by individuals other than parents or guardians, relatives by blood, marriage, or adoption, and in a place other than the home of the person cared for. A facility such as the above with four or fewer persons shall be classified as an R-3 or shall comply with the International Residential Code in accordance with Section 101.2. Places of worship during religious functions and Group E child day care centers are not included.

    (13) Section 308.5.2 is deleted and replaced with the following:

    308.5.2 Child care facility. A facility that provides supervision and personal care on less than a 24 hour basis for more than 100 children 2 1/2 years of age or less shall be classified as Group I-4.

    (14) Section 310.1 is deleted and replaced with the following:

    310.1 Residential Group "R". Residential Group R includes, among others, the use of a building or structure, or a portion thereof, for sleeping purposes when not classed as an Institutional Group I. Residential occupancies shall include the following:

    R-1: Residential occupancies where the occupants are primarily transient in nature (less than 30 days) including: Boarding Houses (transient) and congregate living facilities, Hotels (transient), and Motels (transient).

    Exception: Boarding houses and congregate living facilities accommodating 10 persons or less shall be classified as a Residential Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2.

    R-2: Residential occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent in nature, including: Apartment Houses, Boarding houses (not transient) and congregate living facilities, Convents, Dormitories, Fraternities and Sororities, Monasteries, Vacation timeshare properties, Hotels (non transient), and Motels (non transient).

    Exception: Boarding houses and congregate living facilities accommodating 10 persons or less shall be classified as a Residential Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2.

    R-3: Residential occupancies where the occupants are primarily permanent in nature and not classified as R-1, R-2, R-4 or I and where buildings do not contain more than two dwelling units, as applicable in Section 101.2, or adult and child care facilities that provide accommodations for five or fewer persons of any age for less than 24 hours. Adult and child care facilities that are within a single family home are permitted to comply with the International Residential Code in accordance with Section 101.2. Areas used for day care purposes may be located in a residential dwelling unit under all of the following conditions:

    1. Compliance with the Utah Administrative Code, R710-8, Day Care Rules, as enacted under the authority of the Utah Fire Prevention Board.

    2. Use is approved by the State Department of Health, as enacted under the authority of the Utah Child Care Licensing Act, UCA, Sections 26-39-101 through 26-39-110, and in any of the following categories:

    a. Utah Administrative Code, R430-50, Residential Certificate Child Care Standards.

    b. Utah Administrative Code, R430-90, Licensed Family Child Care.

    3. Compliance with all zoning regulations of the local regulator.

    R-4: Residential occupancies shall include buildings arranged for occupancy as Residential Care/Assisted Living Facilities or Residential Treatment/Support Assisted Living Facilities including more than five but not more than 16 occupants, excluding staff.

    Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3 except as otherwise provided for in this code or shall comply with the International Residential Code in accordance with Section 101.2.

    (15) In Section 310.2 the definition for Residential Care/Assisted Living Facilities is deleted and replaced with the following:

    See Section 308.1.1.

    (16) A new section 421 is added as follows:

    Section 421 Group E Child Day Care Centers. Group E child day care centers shall comply with Section 421.

    421.1 Location at grade. Group E child day care centers shall be located at the level of exit discharge.

    Exception: Child day care spaces for children over the age of 24 months may be located on the second floor of buildings equipped with automatic fire protection throughout and an automatic fire alarm system.

    421.2 Egress. All Group E child day care spaces with an occupant load of more than 10 shall have a second means of egress. If the second means of egress is not an exit door leading directly to the exterior, the room shall have an emergency escape and rescue window complying with Section 1026.

    (17) In Section 504.2 a new section is added as follows:

    504.2.1 Notwithstanding the exceptions to Section 504.2, Group I-2 Assisted Living Facilities shall be allowed to be two stories of Type V-A construction when all of the following apply:

    1. All secured units are located at the level of exit discharge in compliance with Section 1008.1.8.3 as amended;

    2. The total combined area of both stories shall not exceed the total allowable area for a one-story building; and

    3. All other provisions that apply in Section 407 have been provided.[

    (18) In Section 707.14.1 Exception 4 is deleted.]

    ([19]18) In Section (F)902, the definition for record drawings is deleted and replaced with the following:

    (F)RECORD DRAWINGS. Drawings ("as builts") that document all aspects of a fire protection system as installed.

    ([20]19) In Section (F)903.2.3 condition 2 is deleted and replaced with the following:

    2. Where a Group F-1 fire area is located more than three stories above the lowest level of fire department vehicle access; or

    ([21]20) In Section (F)903.2.6 condition 2 is deleted and replaced with the following:

    2. Where a Group M fire area is located more than three stories above the lowest level of fire department vehicle access; or

    ([22]21) Section (F)903.2.7 is deleted and replaced with the following:

    (F)903.2.7 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area.

    Exceptions:

    1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) constructed in accordance with the International Residential Code For One- and Two-Family Dwellings.

    2. Group R-4 fire areas not more than 4,500 gross square feet and not containing more than 16 residents, provided the building is equipped throughout with an approved fire alarm system that is interconnected and receives it primary power from the building wiring and a commercial power system.

    ([23]22) In Section F903.2.8 condition 2 is deleted and replaced with the following:

    2. Where a Group S-1 fire area is located more than three stories above the lowest level of fire department vehicle access; or

    ([24]23) Section (F)903.2.9 is deleted and replaced with the following:

    (F)903.2.9 Group S-2. An automatic sprinkler system shall be provided throughout buildings classified as parking garages in accordance with Section 406.2 or where located beneath other groups.

    Exception 1: Parking garages of less than 5,000 square feet (464 m2)accessory to Group R-3 occupancies.

    Exception 2: Open parking garages not located beneath other groups if one of the following conditions is met:

    a. Access is provided for fire fighting operations to within 150 feet (45,720 mm) of all portions of the parking garage as measured from the approved fire department vehicle access; or

    b. Class I standpipes are installed throughout the parking garage.

    ([25]24) In Section (F)903.2.9.1 the last clause "where the fire area exceeds 5,000 square feet (464 m2)" is deleted.

    ([26]25) Section (F)904.11 and Subsections (F)904.11.3, (F)904.11.3.1, (F)904.11.4 and (F)904.11.4.1 are deleted and replaced with the following:

    (F)904.11 Commercial cooking systems. The automatic fire-extinguishing system for commercial cooking systems shall be of a type recognized for protection of commercial cooking equipment and exhaust systems of the type and arrangement protected. Pre-engineered automatic extinguishing systems shall be tested in accordance with UL 300 and listed and labeled for the intended application. The system shall be installed in accordance with this code, its listing and the manufacturer's installation instructions. Automatic fire-extinguishing systems shall be installed in accordance with the referenced standard for wet-chemical extinguishing systems, NFPA 17A.

    Exception: Factory-built commercial cooking recirculating systems that are tested in accordance with UL 710B and listed, labeled and installed in accordance with Section 304.1 of the International Mechanical Code.

    (Subsections (F)904.11.1 and (F)904.11.2 remain unchanged.

    ([27]26) Section (F)907.2.10 is deleted and replaced with the following:

    (F)907.2.10 Single- and multiple-station alarms. Listed single- and multiple-station smoke alarms complying with U.L. 217 shall be installed in accordance with the provision of this code and the household fire-warning equipment provision of NFPA 72. Listed single- and multiple-station carbon monoxide detectors shall comply with U.L. 2034 and shall be installed in accordance with the provisions of this code and NFPA 720.

    (F)907.2.10.1 Smoke alarms. Single- or multiple-station smoke alarms shall be installed in the locations described in Sections (F)907.2.10.1.1 through (F)907.2.10.1.3.

    (F)907.2.10.1.1 Group R-1. Single- or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1:

    1. In sleeping areas.

    2. In every room in the path of the means of egress from the sleeping area to the door leading from the sleeping unit.

    3. In each story within the sleeping unit, including basements. For sleeping units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.

    (F)907.2.10.1.2 Groups R-2, R-3, R-4 and I-1. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and I-1, regardless of occupant load at all of the following locations:

    1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.

    2. In each room used for sleeping purposes.

    3. In each story within a dwelling unit, including basements and cellars but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.

    (F)907.2.10.1.3 Group I-1. Single- or multiple-station smoke alarms shall be installed and maintained in sleeping areas in occupancies in Group I-1.

    Exception: Single- or multiple-station smoke alarms shall not be required where the building is equipped throughout with an automatic fire detection system in accordance with Section (F)907.2.6.

    (F)907.2.10.2 Carbon monoxide alarms. Carbon monoxide alarms shall be installed on each habitable level of a dwelling unit or sleeping unit in Groups R-2, R-3, R-4 and I-1 equipped with fuel burning appliances.

    (F)907.2.10.3. Power source. In new construction, required alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery backup. Alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection.

    Exception: Alarms are not required to be equipped with battery backup in Group R-1 where they are connected to an emergency electrical system.

    (F)907.2.10.4 Interconnection. Where more than one alarm is required to be installed with an individual dwelling unit in Group R-2, R-3, or R-4, or within an individual sleeping unit in Group R-1, the alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Approved combination smoke and carbon-monoxide detectors shall be permitted.

    (F)907.2.10.5 Acceptance testing. When the installation of the alarm devices is complete, each detector and interconnecting wiring for multiple-station alarm devices shall be tested in accordance with the household fire warning equipment provisions of NFPA 72 and NFPA 720, as applicable.

    ([28]27) In Section 1007.3 a new exception 6 is added as follows:

    6. Areas of refuge are not required at exit stairways in buildings or facilities equipped throughout with an automatic fire sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2.

    ([29]28) In Section 1007.4 the word "exception" is changed to "exception 1" and an exception 2 is added as follows:

    2. Elevators are not required to be accessed from an area of refuge or horizontal exit in buildings or facilities equipped throughout with an automatic fire sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2.

    ([30]29) In Section 1008.1.8.3, a new subparagraph (5) is added as follows:

    (5) Doors in Group I-1 and I-2 occupancies, where the clinical needs of the patients require specialized security measures for their safety, approved access controlled egress may be installed when all the following are met:

    5.1 The controlled egress doors shall unlock upon activation of the automatic fire sprinkler system or automatic fire detection system.

    5.2 The facility staff can unlock the controlled egress doors by either sensor or keypad.

    5.3 The controlled egress doors shall unlock upon loss of power.

    ([31]30) In Section 1009.3, Exception #4 is deleted and replaced with the following:

    4. In Group R-3 occupancies, within dwelling units in Group R-2 occupancies, and in Group U occupancies that are accessory to a Group R-3 occupancy, or accessory to individual dwelling units in Group R-2 occupancies, the maximum riser height shall be 8 inches (203 mm) and the minimum tread depth shall be 9 inches (229 mm). The minimum winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum winder tread depth shall be 6 inches (152 mm). A nosing not less than 0.75 inch (19.1 mm) but not more than 1.25 inches (32 mm) shall be provided on stairways with solid risers where the tread depth is less than 10 inches (254 mm).

    ([32]31) In Section 1009.10 Exception 6 is added as follows:

    6. In occupancies in Group R-3, as applicable in Section 101.2 and in occupancies in Group U, which are accessory to an occupancy in Group R-3, as applicable in Section 101.2, handrails shall be provided on at least one side of stairways consisting of four or more risers.

    ([33]32) Section 1012.3 is amended to include the following exception at the end of the section:

    Exception. Non-circular handrails serving an individual unit in a Group R-1, Group R-2 or Group R-3 occupancy with a perimeter greater than 6 1/4 inches (160 mm) shall provide a graspable finger recess area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest portion of the profile. This required depth shall continue for at least 3/8 inch (10 mm) to a level that is not less than 1 3/4 inches (45 mm) below the tallest portion of the profile. The minimum width of the handrail above the recess shall be 1 1/4 inches (32 mm) to a maximum of 2 3/4 inches (70 mm). Edges shall have a minimum radius of 0.01 inch (0.25 mm).

    ([34]33) In Section 1013.2 Exception 3 is added as follows:

    3. For occupancies in Group R-3 and within individual dwelling units in occupancies in Group R-2, as applicable in Section 101.2, guards shall form a protective barrier not less than 36 inches (914 mm) in height.

    ([35]34) In Section 1015.2.2 the following sentence is added at the end:

    Additional exits or exit access doorways shall be arranged a reasonable distance apart so that if one becomes blocked, the others will be available.

    ([36]35) A new Section 1109.7.1 is added as follows:

    1109.7.1 Platform (wheelchair) lifts. All platform (wheelchair) lifts shall be capable of independent operation without a key.

    ([37]36) In Section 1208.4 subparagraph 1 is deleted and replaced with the following:

    1. The unit shall have a living room of not less than 165 square feet (15.3 m2) of floor area. An additional 100 square feet (9.3 m2) of floor area shall be provided for each occupant of such unit in excess of two.

    ([38]37) Section 1405.3 is deleted and replaced with the following:

    1405.3 Flashing. Flashing shall be installed in such a manner so as to prevent moisture from entering the wall or to redirect it to the exterior. Flashings shall be installed at the perimeters of exterior door and window assemblies, penetrations and terminations of exterior wall assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies and similar projections and at built-in gutters and similar locations where moisture could enter the wall. Flashing with projected flanges shall be installed on both sides and the ends of copings, under sills and continuously above projected trim. A flashing shall be installed at the intersection of the foundation to stucco, masonry, siding or brick veneer. The flashing shall be on an approved corrosion-resistant flashing with a 1/2" drip leg extending past exterior side of the foundation.

    ([39]38) In Section 1605.2.1, the formula shown as "f2 = 0.2 for other roof configurations" is deleted and replaced with the following:

    f2 = 0.20 + .025(A-5) for other configurations where roof snow load exceeds 30 psf

    f2 = 0 for roof snow loads of 30 psf (1.44kN/m2) or less.

    Where A = Elevation above sea level at the location of the structure (ft/1000).

    ([40]39) In Section 1605.3.1 and section 1605.3.2, Exception number 2 in each section is deleted and replaced with the following:

    2. Flat roof snow loads of 30 pounds per square foot (1.44 kNm2) or less need not be combined with seismic loads. Where flat roof snow loads exceed 30 pounds per square foot (1.44 kNm2), the snow loads may be reduced in accordance with the following in load combinations including both snow and seismic loads. Ws as calculated below, shall be combined with seismic loads.

    Ws = (0.20 + 0.025(A-5))Pf is greater than or equal to 0.20 Pf

    Where

    Ws = Weight of snow to be included in seismic calculations;

    A = Elevation above sea level at the location of the structure (ft/1000)

    Pf = Design roof snow load, psf

    For the purpose of this section, snow load shall be assumed uniform on the roof footprint without including the effects of drift or sliding. The Importance Factor, I, used in calculating Pf may be considered 1.0 for use in the formula for Ws.

    ([41]40) In Table 1607.1 number 9 is deleted and replaced with the following:

     

    TABLE 1607.1 NUMBER 9

    Occupancy or Use                     Uniform    Concentrated
    (psf) (lbs)
    9. Decks, except residential Same as occupancy
    servedh
    9.1 Residential decks 60 psf

     

    ([42]41) Section 1608.1 is deleted and replaced with the following:

    1608.1 General. Except as modified in section 1608.1.1, 1608.1.2, and 1608.1.3 design snow loads shall be determined in accordance with Section 7 of ASCE 7, but the design roof load shall not be less than that determined by Section 1607.

    ([43]42) Section 1608.1.1 is added as follows:

    1608.1.1 Section 7.4.5 of Section 7 of ASCE 7 referenced in Section 1608.1 of the IBC is deleted and replaced with the following:

    Section 7.4.5 Ice Dams and Icicles Along Eaves. Where ground snow loads exceed 75 psf, eaves shall be capable of sustaining a uniformly distributed load of 2pf on all overhanging portions. No other loads except dead loads shall be present on the roof when this uniformly distributed load is applied. All building exits under down-slope eaves shall be protected from sliding snow and ice.

    ([44]43) Section 1608.1.2 is added as follows:

    1608.1.2 Utah Snow Loads. The ground snow load, Pg, to be used in the determination of design snow loads for buildings and other structures shall be determined by using the following formula: Pg = (Po2 + S2(A-Ao)2)0.5 for A greater than Ao, and Pg = Po for A less than or equal to Ao.

    WHERE

    Pg = Ground snow load at a given elevation (psf)

    Po = Base ground snow load (psf) from Table No. 1608.1.2(a)

    S = Change in ground snow load with elevation (psf/100 ft.) From Table No. 1608.1.2(a)

    A = Elevation above sea level at the site (ft./1000)

    Ao = Base ground snow elevation from Table 1608.1.2(a) (ft./1000)

    The building official may round the roof snow load to the nearest 5 psf. The ground snow load, Pg, may be adjusted by the building official when a licensed engineer or architect submits data substantiating the adjustments. A record of such action together with the substantiating data shall be provided to the division for a permanent record.

    The building official may also directly adopt roof snow loads in accordance with Table 1608.1.2(b), provided the site is no more than 100 ft. higher than the listed elevation.

    Where the minimum roof live load in accordance with section 1607.11 is greater than the design roof snow load, such roof live load shall be used for design, however, it shall not be reduced to a load lower than the design roof snow load. Drifting need not be considered for roof snow loads less than 20 psf.

    ([45]44) Table 1608.1.2(a) and Table 1608.1.2(b) are added as follows:

     

    TABLE NO. 1608.1.2(a)
    STATE OF UTAH - REGIONAL SNOW LOAD FACTORS


    COUNTY Po S Ao

    Beaver 43 63 6.2
    Box Elder 43 63 5.2
    Cache 50 63 4.5
    Carbon 43 63 5.2
    Daggett 43 63 6.5
    Davis 43 63 4.5
    Duchesne 43 63 6.5
    Emery 43 63 6.0
    Garfield 43 63 6.0
    Grand 36 63 6.5
    Iron 43 63 5.8
    Juab 43 63 5.2
    Kane 36 63 5.7
    Millard 43 63 5.3
    Morgan 57 63 4.5
    Piute 43 63 6.2
    Rich 57 63 4.1
    Salt Lake 43 63 4.5
    San Juan 43 63 6.5
    Sanpete 43 63 5.2
    Sevier 43 63 6.0
    Summit 86 63 5.0
    Tooele 43 63 4.5
    Uintah 43 63 7.0
    Utah 43 63 4.5
    Wasatch 86 63 5.0
    Washington 29 63 6.0
    Wayne 36 63 6.5
    Weber 43 63 4.5

     

    TABLE NO. 1608.1.2(b)
    RECOMMENDED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS(2)


    Roof Snow Ground Snow
    Load (PSF) Load (PSF)

    Beaver County
    Beaver 5920 ft. 43 62
    Box Elder County
    Brigham City 4300 ft. 30 43
    Tremonton 4290 ft. 30 43
    Cache County
    Logan 4530 ft. 35 50
    Smithfield 4595 ft. 35 50
    Carbon County
    Price 5550 ft. 30 43
    Daggett County
    Manila 5377 ft. 30 43
    Davis County
    Bountiful 4300 ft. 30 43
    Farmington 4270 ft. 30 43
    Layton 4400 ft. 30 43
    Fruit Heights 4500 ft. 40 57
    Duchesne County
    Duchesne 5510 ft. 30 43
    Roosevelt 5104 ft. 30 43
    Emery County
    Castledale 5660 ft. 30 43
    Green River 4070 ft. 25 36
    Garfield County
    Panguitch 6600 ft. 30 43
    Grand County
    Moab 3965 ft. 25 36
    Iron County
    Cedar City 5831 ft. 30 43
    Juab County
    Nephi 5130 ft. 30 43
    Kane County
    Kanab 5000 ft. 25 36
    Millard County
    Millard 5000 ft. 30 43
    Delta 4623 ft. 30 43
    Morgan County
    Morgan 5064 ft. 40 57
    Piute County
    Piute 5996 ft. 30 43
    Rich County
    Woodruff 6315 ft. 40 57
    Salt Lake County
    Murray 4325 ft. 30 43
    Salt Lake City 4300 ft. 30 43
    Sandy 4500 ft. 30 43
    West Jordan 4375 ft. 30 43
    West Valley 4250 ft. 30 43
    San Juan County
    Blanding 6200 ft. 30 43
    Monticello 6820 ft. 35 50
    Sanpete County
    Fairview 6750 ft. 35 50
    Mt. Pleasant 5900 ft. 30 43
    Manti 5740 ft. 30 43
    Ephraim 5540 ft. 30 43
    Gunnison 5145 ft. 30 43
    Sevier County
    Salina 5130 ft. 30 43
    Richfield 5270 ft. 30 43
    Summit County
    Coalville 5600 ft. 60 86
    Kamas 6500 ft. 70 100
    Park City 6800 ft. 100 142
    Park City 8400 ft. 162 231
    Summit Park 7200 ft. 90 128
    Tooele County
    Tooele 5100 ft. 30 43
    Uintah County
    Vernal 5280 ft. 30 43
    Utah County
    American Fork 4500 ft. 30 43
    Orem 4650 ft. 30 43
    Pleasant Grove 5000 ft. 30 43
    Provo 5000 ft. 30 43
    Spanish Fork 4720 ft. 30 43
    Wasatch County
    Heber 5630 ft. 60 86
    Washington County
    Central 5209 ft. 25 36
    Dameron 4550 ft. 25 36
    Leeds 3460 ft. 20 29
    Rockville 3700 ft. 25 36
    Santa Clara 2850 ft. 15 (1) 21
    St. George 2750 ft. 15 (1) 21
    Wayne County
    Loa 7080 ft. 30 43
    Hanksville 4308 ft. 25 36
    Weber County
    North Ogden 4500 ft. 40 57
    Ogden 4350 ft. 30 43

    NOTES
    (1) The IBC requires a minimum live load - See 1607.11.2.
    (2) This table is informational only in that actual site
    elevations may vary. Table is only valid if site elevation is
    within 100 feet of the listed elevation.

     

    ([46]45) Section 1608.1.3 is added as follows:

    1608.1.3 Thermal Factor. The value for the thermal factor, Ct, used in calculation of pf shall be determined from Table 7.3 in ASCE 7.

    Exception: Except for unheated structures, the value of Ct need not exceed 1.0 when ground snow load, Pg is calculated using Section 1608.1.2 as amended.

    ([47]46) Section 1608.2 is deleted and replaced with the following:

    1608.2 Ground Snow Loads. The ground snow loads to be used in determining the design snow loads for roofs in states other than Utah are given in Figure 1608.2 for the contiguous United States and Table 1608.2 for Alaska. Site-specific case studies shall be made in areas designated CS in figure 1608.2. Ground snow loads for sites at elevations above the limits indicated in Figure 1608.2 and for all sites within the CS areas shall be approved. Ground snow load determination for such sites shall be based on an extreme value statistical analysis of data available in the vicinity of the site using a value with a 2-percent annual probability of being exceeded (50-year mean recurrence interval). Snow loads are zero for Hawaii, except in mountainous regions as approved by the building official.

    ([48]47) In Section 1609.1.1 a new exception number 5 is added as follows:

    5. The wind design procedure as found in Section 1616 through 1624 of the 1997 Uniform Building Code may be used as an alternative wind design procedure for:

    (a) items 1 through 3 listed in Table 16-H of the 1997 Uniform Building Code provided that the building or component being designed meets the limits for the Simplified Method as defined in ASCE 6.4.1.1 and 6.4.1.2 of ASCE 7; or

    (b) items 4 through 7 listed in Table 16-H of the 1997 Uniform Building Code.

    The Importance Factor, I, shall be determined in accordance with Table 6-1 of ASCE 7.

    ([49]48) Section 1613.7 is added as follows:

    1613.7 ASCE 12.7.2 and 12.14.18.1 of Section 12 of ASCE 7 referenced in Section 1613.1, Definition of W, Item 4 is deleted and replaced with the following:

    4. Where the flat roof snow load, Pf, exceeds 30 psf, the snow load included in seismic design shall be calculated, in accordance with the following formula: Ws = (0.20 + 0.025(A-5))Pf is greater than or equal to 0.20 Pf

    WHERE:

    Ws = Weight of snow to be included in seismic calculations;

    A = Elevation above sea level at the location of the structure (ft/1000)

    Pf = Design roof snow load, psf

    For the purposes of this section, snow load shall be assumed uniform on the roof footprint without including the effects of drift or sliding. The Importance Factor, I, used in calculating Pf may be considered 1.0 for use in the formula for Ws.

    ([50]49) A new Section 1613.8 is added as follows:

    1613.8 ASCE 7, Section 13.5.6.2.2 paragraph (e) is modified to read as follows:

    (e) Penetrations shall have a sleeve or adapter through the ceiling tile to allow for free movement of at least 1 inch (25 mm) in all horizontal directions.

    Exceptions:

    1. Where rigid braces are used to limit lateral deflections.

    2. At fire sprinkler heads in frangible surfaces per NFPA 13.

    ([51]50) Section 1805.5 is deleted and replaced with the following:

    1805.5 Foundation walls. Concrete and masonry foundation walls shall be designed in accordance with Chapter 19 or 21, respectively. Foundation walls that are laterally supported at the top and bottom and within the parameters of Tables 1805.5(1) through 1805.5(5) are permitted to be designed and constructed in accordance with Sections 1805.5.1 through 1805.5.5. Concrete foundation walls may also be constructed in accordance with Section 1805.5.8.

    ([52]51) A new section 1805.5.8 is added as follows:

    1805.5.8 Empirical foundation design. Group R, Division 3 Occupancies three stories or less in height, and Group U Occupancies, which are constructed in accordance with Section 2308, or with other methods employing repetitive wood-frame construction or repetitive cold-formed steel structural member construction, shall be permitted to have concrete foundations constructed in accordance with Table 1805.5(6).

    ([53]52) Table 1805.5(6) is added as follows:

    Table 1805.5(6), entitled "Empirical Foundation Walls, dated January 1, 2007, published by the Department of Commerce, Division of Occupational and Professional Licensing is hereby adopted and incorporated by reference. Table 1805.5(6) identifies foundation requirements for empirical walls.

    ([54]53) A new section 2306.1.5 is added as follows:

    2306.1.5 Load duration factors. The allowable stress increase of 1.15 for snow load, shown in Table 2.3.2, Frequently Used Load Duration Factors, Cd, of the National Design Specifications, shall not be utilized at elevations above 5,000 feet (1524 M).

    ([55]54) In Section 2308.6 the following exception is added:

    Exception: Where foundation plates or sills are bolted or anchored to the foundation with not less than 1/2 inch (12.7 mm) diameter steel bolts or approved anchors, embedded at least 7 inches (178 mm) into concrete or masonry and spaced not more than 32 inches (816 mm) apart, there shall be a minimum of two bolts or anchor straps per piece located not less than 4 inches (102 mm) from each end of each piece. A properly sized nut and washer shall be tightened on each bolt to the plate.

    ([56]55) Section 2506.2.1 is deleted and replaced with the following:

    2506.2.1 Other materials. Metal suspension systems for acoustical and lay-in panel ceilings shall conform with ASTM C635 listed in Chapter 35 and Section 13.5.6 of ASCE 7-05, as amended in Section 1613.8, for installation in high seismic areas.

    ([57]56) In Section 2902.1, the title for Table 2902.1 is deleted and replaced with the following and footnote e is added as follows: Table 2902.1, Minimum Number of Required Plumbing Facilitiesa, e.

    FOOTNOTE: e. When provided, in public toilet facilities there shall be an equal number of diaper changing facilities in male toilet rooms and female toilet rooms.

    ([58]57) Section 3006.5 Shunt Trip, the following exception is added:

    Exception: Hydraulic elevators and roped hydraulic elevators with a rise of 50 feet or less.

    ([59]58) A new section 3403.2.4 is added as follows:

    3403.2.4 Parapet bracing, wall anchors, and other appendages. Buildings constructed prior to 1975 shall have parapet bracing, wall anchors, and appendages such as cornices, spires, towers, tanks, signs, statuary, etc. evaluated by a licensed engineer when said building is undergoing reroofing, or alteration of or repair to said feature. Such parapet bracing, wall anchors, and appendages shall be evaluated in accordance with 75% of the seismic forces as specified in Section 1613. When allowed by the local building official, alternate methods of equivalent strength as referenced in Subsection R156-56-701(2) will be considered when accompanied by engineer sealed drawings, details and calculations. When found to be deficient because of design or deteriorated condition, the engineer's recommendations to anchor, brace, reinforce, or remove the deficient feature shall be implemented.

    EXCEPTIONS:

    1. Group R-3 and U occupancies.

    2. Unreinforced masonry parapets need not be braced according to the above stated provisions provided that the maximum height of an unreinforced masonry parapet above the level of the diaphragm tension anchors or above the parapet braces shall not exceed one and one-half times the thickness of the parapet wall. The parapet height may be a maximum of two and one-half times its thickness in other than Seismic Design Categories D, E, or F.

    ([60]59) Section 3406.4 is deleted and replaced with the following:

    3406.4 Change in Occupancy. When a change in occupancy results in a structure being reclassified to a higher Occupancy Category (as defined in Table 1604.5), or when such change of occupancy results in a design occupant load increase of 100% or more, the structure shall conform to the seismic requirements for a new structure.

    Exceptions:

    1. Specific seismic detailing requirements of this code or ASCE 7 for a new structure shall not be required to be met where it can be shown that the level of performance and seismic safety is equivalent to that of a new structure. Such analysis shall consider the regularity, overstrength, redundancy and ductility of the structure within the context of the existing and retrofit (if any) detailing providing. Alternatively, the building official may allow the structure to be upgraded in accordance with referenced sections as found in Subsection R156-56-701(2).

    2. When a change of use results in a structure being reclassified from Occupancy Category I or II to Occupancy Category III and the structure is located in a seismic map area where SDS is less than 0.33, compliance with the seismic requirements of this code and ASCE 7 are not required.

    3. Where design occupant load increase is less than 25 occupants and the Occupancy Category does not change.

    ([61]60) The exception in 3409.1 is deleted and replaced with the following:

    Exception: Type B dwelling or sleeping units required by section 1107 are not required to be provided in existing buildings and facilities, except when an existing occupancy is changed to R-2.

    ([62]61) In Section 3409.4, number 7 is added as follows:

    7. When a change of occupancy in a building or portion of a building results in a Group R-2 occupancy as determined in section 1107.6.2, not less than 20 percent of the dwelling or sleeping units shall be Type B dwelling or sleeping units. These dwelling or sleeping units may be located on any floor of the building provided with an accessible route. Two percent, but not less than one, of the dwelling or sleeping units shall be Type A dwelling units.

    ([63]62) The following referenced standard is added under NFPA in chapter 35:

     

    TABLE

                                                  Referenced in code
    Number Title Section number
    720-05 Recommended Practice for the 907.2.10, 907.2.10.5
    Installation of Household Carbon
    Monoxide (CO) Warning Equipment

     

    KEY: contractors, building codes, building inspections, licensing

    Date of Enactment or Last Substantive Amendment: [July 1, ]2008

    Notice of Continuation: March 29, 2007

    Authorizing, and Implemented or Interpreted Law: 58-1-106(1)(a); 58-1-202(1)(a); 58-56-1; 58-56-4(2); 58-56-6(2)(a); 58-56-18; 58-56-19

     

Document Information

Effective Date:
12/8/2008
Publication Date:
11/01/2008
Filed Date:
10/06/2008
Agencies:
Commerce,Occupational and Professional Licensing
Rulemaking Authority:

Sections 58-56-1 and 58-56-19, and Subsections 58-1-106(1)(a), 58-5-202(1)(a), 58-56-4(2), and 58-56-6(2)(a)

Authorized By:
F. David Stanley, Director
DAR File No.:
32001
Related Chapter/Rule NO.: (1)
R156-56. Utah Uniform Building Standard Act Rules.