No. 30574 (Amendment): R156-56. Utah Uniform Building Standard Act Rules.  

  • DAR File No.: 30574
    Filed: 10/11/2007, 03:50
    Received by: NL

    RULE ANALYSIS

    Purpose of the rule or reason for the change:

    The Division is proposing changes to the rule to adopt amendments to the building codes approved by the Uniform Building Code Commission after review by various subcommittees.

    Summary of the rule or change:

    Subsection R156-56-202(1) is a technical change to correct outdated statutory references. In Section R156-56-401, moved Daniels designation of DAN to correct column. Subsection R156-56-801(47) is a technical correction clarifying when alternative wind design procedures may be used. Subsections R156-56-801(58) and R156-56-820(4) are technical corrections to clarify the requirement that an engineer's recommendation for corrective action must be implemented when deficient conditions are found in certain buildings undergoing remodeling. Subsections R156-56-803(52) and (56) are additions to the rule which allow tested air admittance valves to be used in limited circumstances such as labs using a chemical waste and vent system. In Subsection R156-56-903(1), Salt Lake City has requested approval of a local amendment which allows gray water recycling in certain nonresidential buildings. Gray water recycling allows nonhazardous wastewater from limited sources such as laundries, showers, or baths to be used for flushing of toilets and urinals within the same building.

    State statutory or constitutional authorization for this rule:

    Section 58-56-1 and Subsections 58-1-106(1)(a), 58-1-202(1)(a), 58-56-4(2), and 58-56-6(2)(a)

    Anticipated cost or savings to:

    the state budget:

    The Division has determined that there should be no direct effect on the state budget as a result of the proposed amendments other than minimal costs to affected state agencies who need to reprint the rule once the proposed amendments are made effective.

    local governments:

    The division has determined that there should be no direct effect on local governments except as noted below. Any net effect will be minimal.

    small businesses and persons other than businesses:

    The division has determined the technical changes will not result in any significant impact on any party. It is unknown how many persons these proposed amendments will affect or the cost of implementation; therefore, it is impossible to determine an aggregate impact. The change to allow air admittance valves in certain applications will result in savings in certain types of buildings such as labs which handle chemicals. This results in a savings to construct redundant venting to outside air. It is impossible to estimate the savings per building or other number of building that this amendment would affect. The local amendment for Salt Lake City will allow for installation of gray water recycling in certain nonresidential buildings. Gray water recycling has not previously been allowed within Utah buildings and would be considered experimental at this time in Utah, although it has been successfully implemented in other jurisdictions such as Las Vegas. At this time the cost to add gray water recycling systems would be substantial and would likely cost substantially more than the cost of the water that it would save. However, as demand for water increases particularly in drier locations, methods of recycling water need to be explored. Codes and rules for how these types of recycling projects would be constructed and monitored have previously been adopted for potential use. This would be the first instance in Utah when those codes are adopted by a local jurisdiction. Existing rules already provide for added monitoring by the Utah Department of Environmental Quality and the Department of Health if such a system is constructed. The Salt Lake City local amendment may result in higher installation costs and ongoing maintenance costs for a limited number of persons but those persons would only voluntarily commit to the additional costs. No one is required to use a gray water recycling system under the code. But if they voluntarily choose to implement such a system, they are required to expend additional costs to assure the health and safety of such a system. It is impossible for the division to determine potential costs of such a system until it is actually designed.

    Compliance costs for affected persons:

    The Division has determined the technical changes will not result in any significant impact on any party. The change to allow air admittance valves in certain applications will result in savings in certain types of buildings such as labs which handle chemicals. This results in a savings to construct redundant venting to outside air. It is impossible to estimate the savings per building or other number of building that this amendment would affect. The local amendment for Salt Lake City will allow for installation of gray water recycling in certain nonresidential buildings. Gray water recycling has not previously been allowed within Utah buildings and would be considered experimental at this time in Utah, although it has been successfully implemented in other jurisdictions such as Las Vegas. At this time the cost to add gray water recycling systems would be substantial and would like cost substantially more than the cost of the water that it would save. However, as demand for water increases particularly in drier locations, methods of recycling water need to be explored. Codes and rules for how these types of recycling projects would be constructed and monitored have previously been adopted for potential use. This would be the first instance in Utah when those codes are adopted by a local jurisdiction. Existing rules already provide for added monitoring by the Utah Department of Environmental Quality and the Department of Health if such a system is constructed. The Salt Lake City local amendment may result in higher installation costs and ongoing maintenance costs for a limited number of persons but those persons would only voluntarily commit to the additional costs. No one is required to use a gray water recycling system under the code. But if they voluntarily choose to implement such a system, they are required to expend additional costs to assure the health and safety of such a system. It is impossible for the division to determine potential costs of such a system until it is actually designed.

    Comments by the department head on the fiscal impact the rule may have on businesses:

    This rule filing permits the use of tested air admittance valves in limited circumstances, which is expected to result in cost savings to the construction industry and owners of buildings. The filing also approves Salt Lake City's request for a local amendment permitting gray water recycling in nonresidential buildings, which is costly but optional. Finally, the rule filing makes various technical amendments which are not expected to result in any fiscal impact to businesses. Francine A. Giani, Executive Director

    The full text of this rule may be inspected, during regular business hours, at the Division of Administrative Rules, or at:

    Commerce
    Occupational and Professional Licensing
    HEBER M WELLS BLDG
    160 E 300 S
    SALT LAKE CITY UT 84111-2316

    Direct questions regarding this rule to:

    Dan S. Jones at the above address, by phone at 801-530-6720, by FAX at 801-530-6511, or by Internet E-mail at dansjones@utah.gov

    Interested persons may present their views on this rule by submitting written comments to the address above no later than 5:00 p.m. on:

    12/03/2007

    Interested persons may attend a public hearing regarding this rule:

    11/15/2007 at 9:00 AM, State Office Building (behind the Capitol), Room 4112, Salt Lake City, UT

    This rule may become effective on:

    12/10/2007

    Authorized by:

    F. David Stanley, Director

    RULE TEXT

    R156. Commerce, Occupational and Professional Licensing.

    R156-56. Utah Uniform Building Standard Act Rules.

    R156-56-202. Advisory Peer Committees Created - Membership - Duties.

    (1) There is created in accordance with Subsection 58-1-203[(6)](1)(f) and 58-56-5(10)([e]d), the following committees as advisory peer committees to the Uniform Building Codes Commission:

    (a) the Education Advisory Committee consisting of seven members;

    (b) the Plumbing and Health Advisory Committee consisting of nine members;

    (c) the Structural Advisory Committee consisting of seven members;

    (d) the Architectural Advisory Committee consisting of seven members;

    (e) the Fire Protection Advisory Committee consisting of five members;

    (i) This committee shall join together with the Fire Advisory and Code Analysis Committee of the Utah Fire Prevention Board to form the Unified Code Analysis Council.

    (ii) The Unified Code Analysis Council shall meet as directed by the Utah Fire Prevention Board or as directed by the Uniform Building Code Commission or as needed to review fire prevention and building code issues that require definitive and specific analysis.

    (iii) The Unified Code Analysis Council shall select one of its members to act in the position of chair and another to act as vice chair. The chair and vice chair shall serve for one year terms on a calendar year basis. Elections for chair and vice chair shall occur at the meeting conducted in the last quarter of the calendar year.

    (iv) The chair or vice chair shall report to the Utah Fire Prevention Board or Uniform Building Code Commission recommendations of the council with regard to the review of fire and building codes;

    (f) the Mechanical Advisory Committee consisting of seven members; and

    (g) the Electrical Advisory Committee consisting of seven members.

    (2) The committees shall be appointed and serve in accordance with Section R156-1-205. The membership of each committee shall be made up of individuals who have direct knowledge or involvement in the area of code involved in the title of that committee.

    (3) The duties and responsibilities of the committees shall include:

    (a) review of requests for amendments to the adopted codes as assigned to each committee by the division with the collaboration of the commission;

    (b) submission of recommendations concerning the requests for amendment; and

    (c) the Education Advisory Committee shall review and make recommendations regarding funding requests which are submitted, and review and make recommendations regarding budget, revenue and expenses of the education fund established pursuant to Subsection 58-56-9(4).

     

    R156-56-401. Standardized Building Permit Number.

    As provided in Section 58-56-18, beginning on January 1, 2007, any agency issuing a permit for construction within the state of Utah shall use the standardized building permit numbering which includes the following:

    (1) The permit number shall consist of 12 digits with the following components in the following order:

    (a) digits one, two and three shall be alphabetical characters identifying the compliance agency issuing the permit as specified in the table in Subsection (3);

    (b) digits four and five shall be numerical characters indicating the year of permit issuance;

    (c) digits six and seven shall be numerical characters indicating the month of permit issuance;

    (d) digits eight and nine shall be numerical characters indicating the day of the month on which the permit is issued; and

    (e) digits ten, eleven and twelve shall be numerical characters used to distinguish between permits issued by the agency on the same day.

    (2) When used in addition to a different permit numbering system, as provided for in Subsection 58-56-18(3)(b), the standardized building permit number shall be clearly identified and labeled as the "state permit number" or "Utah permit number".

    (3) The following table establishes the three digit alphabetical character for which the compliance agency shall be identified as provided in Subsection (1)(a):

     

    TABLE
    COMPLIANCE AGENCY PERMIT TABLE
    FOR STANDARDIZED BUILDING PERMIT
    THREE LETTER DESIGNATIONS


    Index:
    Column 1: City, town, or other compliance agency in
    which project is located
    Column 2: County in which the city, town, or other
    compliance agency is located
    Column 3: City, town or other compliance agency
    3 digit designation (Designation is shown for cities,
    towns, or other compliance agency which issue
    building permits. If no designation is shown, the
    building permits for the city, town, or other
    compliance agency are issued by the county, therefore
    the county three digit designation should be used)
    Column 4: County 3 digit designation


    1 2 3 4
    City, Town, County City, Town, County
    or other or other Designa-
    Compliance Agency Compliance tion
    Agency
    Designation
    Adamsville BEAVER BVR
    Alpine UTAH ALP
    Alta SALT LAKE ALT
    Altamont DUCHESNE DCH
    Alton KANE KAN
    Altonah DUCHESNE DCH
    Amalga CACHE CAC
    American Fork UTAH AFC
    Aneth SAN JUAN SJC
    Angle PIUTE PIU
    Annabella SEVIER SEV
    Antimony GARFIELD GRF
    Apple Valley WASHINGTON WSC
    Aragonite TOOELE TOC
    Aurora SEVIER SEV
    Austin SEVIER SEV
    Avon CACHE CAC
    Axtell SANPETE SPC
    Bacchus SALT LAKE SCO
    Ballard UINTAH BAL
    Bauer TOOELE TOC
    Bear River BOX ELDER BRC
    Beaver City BEAVER BEA
    BEAVER COUNTY BVR
    Beaver Dam BOX ELDER BEC
    Benjamin UTAH UTA
    Benson CACHE CAC
    Beryl IRON IRO
    Bicknell WAYNE WAY
    Big Water KANE BWM
    Birdseye UTAH UTA
    Black Rock MILLARD MIL
    Blanding SAN JUAN BLA
    Bloomington Hills WASHINGTON STG (part of St.
    George)
    Bloomington WASHINGTON STG (part of St.
    George)
    Blue Creek BOX ELDER BEC
    Bluebell DUCHESNE DCH
    Bluff SAN JUAN SJC
    Bluffdale SALT LAKE BLU
    Bonanza UINTAH UTC
    Boneta DUCHESNE DCH
    Bothwell BOX ELDER BEC
    Boulder GARFIELD GRF
    Bountiful DAVIS BOU
    BOX ELDER COUNTY BEC
    Brian Head IRON BHT
    Bridgeland DUCHESNE DCH
    Brigham BOX ELDER BRI
    Brighton SALT LAKE SCO
    Brookside WASHINGTON WSC
    Bryce GARFIELD GRF
    Bullfrog KANE KAN
    Burmester TOOELE TOC
    Burrville SEVIER SEV
    CACHE COUNTY CAC
    Cache Junction CACHE CAC
    Caineville WAYNE WAY
    Callao JUAB JUA
    Camp Williams UTAH UTA
    Cannonville GARFIELD GRF
    CARBON COUNTY CAR
    Carbonville CARBON CAR
    Castle Dale EMERY EMR
    Castle Rock SUMMIT SUM
    Castle Valley GRAND GRA
    Cedar City IRON CEC
    Cedar Creek BOX ELDER BEC
    Cedar Fort UTAH CFT
    Cedar Hills UTAH CDH
    Cedar Mountain TOOELE TOC
    Cedar Springs BOX ELDER BEC
    Cedar Valley UTAH UTA
    Cedarview DUCHESNE DCH
    Center Creek WASATCH WAC
    Centerfield SANPETE SPC
    Centerville DAVIS CEV
    Central SEVIER SEV
    Central WASHINGTON WSC
    Central Valley SEVIER SEV
    Charleston WASATCH CHA
    Chester SANPETE SPC
    Christinburg SANPETE SPC
    Christmas Meadows SUMMIT SUM
    Church Wells KANE KAN
    Circleville PIUTE CIR
    Cisco GRAND GRA
    Clarkston CACHE CAC
    Clawson EMERY EMR
    Clear Lake MILLARD MIL
    Clearcreek BOX ELDER BEC
    Clearcreek CARBON CAR
    Clearfield DAVIS CLE
    Cleveland EMERY EMR
    Clinton DAVIS CLI
    Clive TOOELE TOC
    Clover TOOELE RUV(became Rush
    Valley)
    Coalville SUMMIT COA
    College Ward CACHE CAC
    Collinston BOX ELDER BEC
    Colton UTAH UTA
    Copperton SALT LAKE SCO
    Corinne BOX ELDER COR
    Cornish CACHE CAC
    Cottonwood SALT LAKE SCO
    Cottonwood Heights SALT LAKE CHC
    Cove CACHE CAC
    Cove Fort MILLARD MIL
    Crescent SALT LAKE SCO
    Crescent Junction GRAND GRA
    Croyden MORGAN MRG
    DAGGETT COUNTY DAG
    Dameron Valley WASHINGTON WSC
    Daniels WASATCH DAN[ DAN]
    DAVIS COUNTY DAV
    Deer Creek WASATCH WAC
    Delle TOOELE TOC
    Delta MILLARD DEL
    Deseret MILLARD MIL
    Deseret Mound IRON IRO
    Devils Slide MORGAN MRG
    Deweyville BOX ELDER DEW
    Diamond Valley WASHINGTON WSC
    Div of Facilities
    Construction and Mgmt (statewide) FCM
    Dividend UTAH UTA
    Draper SALT LAKE DRA
    Draper City South UTAH UTA
    Duchesne City DUCHESNE DUC
    DUCHESNE COUNTY DCH
    Duck Creek KANE KAN
    Dugway (Federal) TOOELE XXX
    Dutch John DAGGETT DAG
    Eagle Mountain UTAH EMC
    East Carbon CARBON ECC
    East Green River GRAND GRA
    East Millcreek SALT LAKE SCO
    Eastland SAN JUAN SJC
    Echo SUMMIT SUM
    Eden WEBER WEB
    Elk Ridge UTAH ERC
    Elberta UTAH UTA
    Elmo EMERY EMR
    Elsinore SEVIER SEV
    Elwood BOX ELDER ELW
    Emery City EMERY EME
    EMERY COUNTY EMR
    Emory SUMMIT SUM
    Enoch IRON ENO
    Enterprise WASHINGTON ENT
    Ephraim SANPETE SPC
    Erda TOOELE TOC
    Escalante GARFIELD GRF
    Eskdale MILLARD MIL
    Etna BOX ELDER BEC
    Eureka JUAB EUR
    Fairfield UTAH UTA
    Fairmont SEVIER SEV
    Fairview SANPETE SPC
    Farmington DAVIS FAR
    Farr West WEBER FAW
    Faust TOOELE TOC
    Fayette SANPETE SPC
    Ferron EMERY EMR
    Fielding BOX ELDER FIE
    Fillmore MILLARD FIL
    Flowell MILLARD MIL
    Fort Duchesne UINTAH UTC
    Fountain Green SANPETE SPC
    Francis SUMMIT FRA
    Freedom SANPETE SPC
    Freeport Circle DAVIS DAV
    Fremont WAYNE WAY
    Fremont Junction SEVIER SEV
    Fruit Heights DAVIS FRU
    Fruitland DUCHESNE DCH
    Fry Canyon SAN JUAN SJC
    Gandy MILLARD MIL
    Garden City RICH GAR
    Garfield SALT LAKE SCO
    GARFIELD COUNTY GRF
    Garland BOX ELDER GRL
    Garrison MILLARD MIL
    Geneva UTAH GEV
    Genola UTAH GEN
    Glendale KANE KAN
    Glenwood SEVIER SEV
    Goldhill TOOELE TOC
    Goshen UTAH GOS
    Grafton WASHINGTON ROC (part of Rock-
    ville)
    GRAND COUNTY GRA
    Granite SALT LAKE SCO
    Grantsville TOOELE GTV
    Green River EMERY EMR
    Greenville BEAVER BVR
    Greenwich PIUTE PIU
    Greenwood MILLARD MIL
    Grouse Creek BOX ELDER BEC
    Grover WAYNE WAY
    Gunlock WASHINGTON WSC
    Gunnison SANPETE SPC
    Gusher UINTAH UTC
    Hailstone WASATCH WAC
    Halls Crossing SAN JUAN SJC
    Hamilton Fort IRON IRO
    Hamlin Valley IRON IRO
    Hanksville WAYNE WAY
    Hanna DUCHESNE DCH
    Harrisville WEBER HAR
    Hatch GARFIELD GRF
    Hatton MILLARD MIL
    Heber WASTACH HEB
    Helper CARBON CAR
    Henefer SUMMIT HEN
    Henrieville GARFIELD GRF
    Herriman SALT LAKE HER
    Hiawatha CARBON CAR
    Hideway Valley SANPETE SPC
    Highland UTAH HIG
    Hildale WASHINGTON HIL
    Hinckley MILLARD HIN
    Hite SAN JUAN SJC
    Holden MILLARD HOL
    Holladay SALT LAKE HOD
    Honeyville BOX ELDER HON
    Hooper WEBER HOO
    Hot Springs BOX ELDER BEC
    Hovenweep Mountain SAN JUAN SJC
    Howell BOX ELDER HPW
    Hoytsville SUMMIT SUM
    Huntington EMERY EMR
    Huntsville WEBER HTV
    Hurricane WASHINGTON HUR
    Hyde Park CACHE HPC
    Hyrum CACHE CAC
    Ibapah TOOELE TOC
    Indianola SANPETE SPC
    Ioka DUCHESNE DCH
    IRON COUNTY IRO
    Iron Springs IRON IRO
    Ivins WASHINGTON INI
    Jensen UINTAH UTC
    Jericho JUAB JUA
    Joseph SEVIER SEV
    JUAB COUNTY JUA
    Junction PIUTE JUN
    Kamas SUMMIT KAM
    Kanab KANE KNB
    Kanarraville IRON IRO
    KANE COUNTY KAN
    Kaneville WEBER WEC
    Kanosh MILLARD KNS
    Kayenta WASHINGTON INI (part of Ivins)
    Kaysville DAVIS KAY
    Kearns SALT LAKE SCO
    Keetley WASATCH WAC
    Kelton BOX ELDER BEC
    Kenilworth CARBON CAR
    Kingston PIUTE KIN
    Knolls TOOELE TOC
    Koosharem SEVIER SEV
    La Sal SAN JUAN SJC
    La Verkin WASHINGTON LAV
    Lake Powell SAN JUAN SJC
    Lakepoint TOOELE TOC
    Lakeshore UTAH UTA
    Lakeside BOX ELDER BEC
    Laketown RICH RIC
    Lakeview UTAH UTA
    Lapoint UINTAH UTC
    Lark SALT LAKE SCO
    Lawrence EMERY EMR
    Layton DAVIS LAY
    Leamington MILLARD LEA
    Leeds WASHINGTON LEE
    Leeton UINTAH UTC
    Lehi UTAH LEH
    Leland UTAH UTA
    Leota UINTAH UTC
    Levan JUAB LEV
    Lewiston CACHE LEW
    Liberty WEBER WEC
    Lincoln TOOELE TOC
    Lindon UTAH LIN
    Little Mountain WEBER WEC
    Littleton MORGAN MRG
    Loa WAYNE LOA
    Logan CACHE LOG
    Long Valley KANE KAN
    Losepa TOOELE TOC
    Low TOOELE TOC
    Lucin BOX ELDER BEC
    Lund IRON IRO
    Lyman WAYNE WAY
    Lynn BOX ELDER BEC
    Lynndyl MILLARD LYN
    Madsen BOX ELDER BEC
    Maeser UINTAH UTC
    Magna SALT LAKE SCO
    Mammoth JUAB JUA
    Manderfield BEAVER BVR
    Manila DAGGETT MNL
    Manti SANPETE SPC
    Mantua BOX ELDER MNT
    Mapleton UTAH MAP
    Marion SUMMIT SUM
    Marriott-Slaterville WEBER MSC
    Marysvale PIUTE MAR
    Mayfield SANPETE SPC
    Meadow MILLARD MEA
    Meadowville RICH RIC
    Mendon CACHE MEN
    Mexican Hat SAN JUAN SJC
    Middleton WASHINGTON STG (part of St.
    George)
    Midvale SALT LAKE MID
    Midway WASATCH MWC
    Milburn SANPETE SPC
    Milford BEAVER MLF
    Mill Fork UTAH UTA
    MILLARD COUNTY MIL
    Mills JUAB JUA
    Mills Junction TOOELE TOC
    Millville CACHE CAC
    Milton MORGAN MRG
    Minersville BEAVER BVR
    Moab GRAND MOA
    Modena IRON IRO
    Mohrland EMERY EMR
    Molen EMERY EMR
    Mona JUAB MON
    Monarch DUCHESNE DCH
    Monroe SEVIER SEV
    Montezuma Creek SAN JUAN SJC
    Monticello SAN JUAN MNC
    Monument Valley SAN JUAN SJC
    Moore EMERY EMR
    Morgan City MORGAN MOR
    MORGAN COUNTY MRG
    Moroni SANPETE SPC
    Mt Carmel KANE KAN
    Mt Emmons DUCHESNE DCH
    Mt Green MORGAN MRG
    Mt Home DUCHESNE DCH
    Mt Olympus SALT LAKE SCO
    Mt Pleasant SANPETE SPC
    Mt Sterling CACHE CAC
    Murray SALT LAKE MUR
    Myton DUCHESNE DCH
    Naples UINTAH NAP
    National CARBON CAR
    Navaho Lake DUCHESNE DCH
    Neola DUCHESNE DCH
    Nephi JUAB NEP
    New Harmony WASHINGTON WSC
    Newcastle IRON IRO
    Newton CACHE NEW
    Nibley CACHE NIB
    North Logan CACHE NLC
    North Ogden WEBER NOC
    North Salt Lake DAVIS NSL
    Oak City MILLARD OAK
    Oakley SUMMIT OKL
    Oasis MILLARD MIL
    Ogden WEBER OGD
    Ogden City School Dist WEBER OSD
    Ophir TOOELE OPH
    Orangeville EMERY ORA
    Orderville KANE KAN
    Orem UTAH ORE
    Orrey WAYNE WAY
    Ouray UINTAH UTC
    Palmyra UTAH UTA
    Panguitch GARFIELD GRF
    Paradise CACHE CAC
    Paragonah IRON IRO
    Park City SUMMIT PAC
    Park City East WASATCH WAC
    Park Valley BOX ELDER BEC
    Parowan IRON IRO
    Partoun JUAB JUA
    Payson UTAH PAY
    Penrose BOX ELDER BEC
    Peoa SUMMIT SUM
    Perry BOX ELDER PER
    Petersboro CACHE CAC
    Peterson MORGAN MRG
    Pickleville RICH RIC
    Pigeon Hollow Junction SANPETE SPC
    Pine Valley WASHINGTON WSC
    Pineview SUMMIT SUM
    Pinto WASHINGTON WSC
    Pintura WASHINGTON WSC
    PIUTE COUNTY PIU
    Plain City WEBER PLA
    Pleasant Grove UTAH PGC
    Pleasant View WEBER PVC
    Plymouth BOX ELDER PLY
    Portage BOX ELDER BEC
    Porterville MORGAN MRG
    Price CARBON PRI
    Promontory BOX ELDER BEC
    Providence CACHE PRV
    Provo UTAH PRO
    Provo Canyon UTAH UTA
    Randlett UINTAH UTC
    Randolph RICH RAN
    Redmond SEVIER RED
    Redmonton BOX ELDER BEC
    RICH COUNTY RIC
    Richfield SEVIER RCF
    Richmond CACHE CAC
    Richville MORGAN MRG
    River Heights CACHE CAC
    Riverdale WEBER RVD
    Riverside BOX ELDER BEC
    Riverton SALT LAKE RVT
    Rockville WASHINGTON ROC
    Rocky Ridge Town JUAB ROR
    Roosevelt DUCHESNE ROO
    Rosette BOX ELDER BEC
    Round Valley RICH RIC
    Roy WEBER ROY
    Rubys Inn GARFIELD GRF
    Rush Valley TOOELE RUV
    Sage Creek Junction RICH RIC
    Salem UTAH SLM
    Salina SEVIER SEV
    Salt Lake City SALT LAKE SLC
    SALT LAKE COUNTY SCO
    Salt Lake Suburban
    Sanitary District #1 SALT LAKE SSD
    Salt Springs TOOELE TOC
    Samak SUMMIT SUM
    SAN JUAN COUNTY SJC
    Sandy SALT LAKE SAN
    SANPETE COUNTY SPC
    Santa Clara WASHINGTON SAC
    Santaquin UTAH STQ
    Saratoga Springs UTAH SRT
    Scipio MILLARD SCI
    Scofield CARBON CAR
    Sevier SEVIER SEV
    SEVIER COUNTY SEV
    Shivwits (Federal) WASHINGTON YYY
    Sigurd SEVIER SEV
    Silver City JUAB JUA
    Silver Creek Junction SUMMIT SUM
    Silver Fork SALT LAKE SCO
    Silver Reef WASHINGTON LEE (part of Leeds)
    Smithfield CACHE SMI
    Snowbird SALT LAKE SCO
    Snowville BOX ELDER SNO
    Snyderville SUMMIT SUM
    Soldier Summit WASATCH WAC
    South Jordan SALT LAKE SOJ
    South Ogden WEBER SOO
    South Salt Lake SALT LAKE SSL
    South Weber DAVIS SWC
    Spanish Fork UTAH SFC
    Spring City SANPETE SPC
    Spring Glen CARBON CAR
    Spring Lake UTAH UTA
    Springdale WASHINGTON SPD
    Springville UTAH SPV
    St George WASHINGTON STG
    St John TOOELE RUV (became Rush
    Valley)
    Standrod BOX ELDER BEC
    Stansbury Park TOOELE TOC
    Sterling SANPETE SPC
    Stockmore DUCHESNE DCH
    Stockton TOOELE STO
    Stoddard MORGAN MRG
    Sugarville MILLARD MIL
    Summit IRON IRO
    SUMMIT COUNTY SUM
    Summit Park SUMMIT SUM
    Summit Point SAN JUAN SJC
    Sundance UTAH UTA
    Sunnyside CARBON CAR
    Sunset DAVIS SUN
    Sutherland MILLARD MIL
    Swan Creek TOOELE TOC
    Syracuse DAVIS SYR
    Tabiona DUCHESNE DCH
    Talmage DUCHESNE DCH
    Taylor WEBER WEC
    Taylorsville SALT LAKE TAY
    Teasdale WAYNE WAY
    Thatcher BOX ELDER THA
    Thistle UTAH UTA
    Thompson Springs GRAND GRA
    Ticaboo GARFIELD GRF
    Timpe TOOELE TOC
    Tintic JUAB JUA
    Tooele City TOOELE TOO
    TOOELE COUNTY TOC
    Toquerville WASHINGTON TOQ
    Torrey WAYNE WAY
    Tremonton BOX ELDER TRE
    Trenton CACHE CAC
    Tridell UINTAH UTC
    Tropic GARFIELD GRF
    Trout Creek JUAB JUA
    Tucker UTAH UTA
    Ucolo SAN JUAN SJC
    Uintah WEBER UIN
    UINTAH COUNTY UTC
    Upalco DUCHESNE DCH
    Upton SUMMIT SUM
    UTAH COUNTY UTA
    Uvada IRON IRO
    Venice SEVIER SEV
    Vernal UINTAH VER
    Vernon TOOELE TOC
    Veyo WASHINGTON WSC
    Vineyard UTAH VIN
    Virgin WASHINGTON VIR
    Wahsatch SUMMIT SUM
    Wales SANPETE SPC
    Wallsburg WASATCH WAC
    Wanship SUMMIT SUM
    Warren WEBER WEC
    WASATCH COUNTY WAC
    Washington City WASHINGTON WAS
    Washakie BOX ELDER BEC
    Washington Terrace WEBER WAT
    WASHINGTON COUNTY WSC
    WAYNE COUNTY WAY
    WEBER COUNTY WEC
    Webster Cove Junction CACHE CAC
    Wellington CARBON CAR
    Wellsville CACHE CAC
    Wendover TOOELE WEN
    West Bountiful DAVIS WEB
    West Haven WEBER WEH
    West Jordan SALT LAKE WEJ
    West Point DAVIS WEP
    West Valley SALT LAKE WVC
    West Warren WEBER WEC
    West Weber WEBER WEC
    Westwater GRAND GRA
    Whiterocks UINTAH UTC
    Widtsoe Junction GARFIELD GRF
    Wildwood UTAH UTA
    Willard BOX ELDER WIL
    Wilson WEBER WEC
    Wins WASHINGTON WSC
    Woodland Hills UTAH WHO
    Woodland SUMMIT SUM
    Woodruff RICH RIC
    Woodrow MILLARD MIL
    Woods Cross DAVIS WXC
    Woodside EMERY EMR
    Yost BOX ELDER BEC
    Young Ward CACHE CAC
    Zane IRON IRO

    R156-56-801. Statewide Amendments to the IBC.

    The following are adopted as amendments to the IBC to be applicable statewide:

    (1) All references to the ICC Electrical Code are deleted and replaced with the National Electrical Code adopted under Subsection R156-56-701(1)(b).

    (2) Section 101.4.1 is deleted and replaced with the following:

    101.4.1 Electrical. The provisions of the National Electrical Code (NEC) shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto.

    (3) Section 106.3.2 is deleted and replaced with the following:

    106.3.2 Previous approval. If a lawful permit has been issued and the construction of which has been pursued in good faith within 180 days after the effective date of the code and has not been abandoned, then the construction may be completed under the code in effect at the time of the issuance of the permit.

    (4) In Section 109, a new section is added as follows:

    109.3.5 Weather-resistive barrier and flashing. An inspection shall be made of the weather-resistive barrier as required by Section 1403.2 and flashing as required by Section 1405.3 to prevent water from entering the weather-resistant exterior wall envelope.

    The remaining sections will be renumbered as follows:

    109.3.6 Lath or gypsum board inspection

    109.3.7 Fire-resistant penetrations

    109.3.8 Energy efficiency inspections

    109.3.9 Other inspections

    109.3.10 Special inspections

    109.3.11 Final inspection.

    (5) Section 114.1 is deleted and replaced with the following:

    114.1 Authority. Whenever the building official finds any work regulated by this code being performed in a manner either contrary to the provisions of this code or other pertinent laws or ordinances or dangerous or unsafe, the building official is authorized to stop work.

    (6) In Section 202, the definition for Assisted Living Facility is deleted and replaced with the following:

    ASSISTED LIVING FACILITY. See Section 308.1.1.

    (7) Section 305.2 is deleted and replaced with the following:

    305.2 Day care. The building or structure, or portion thereof, for educational, supervision, child day care centers, or personal care services of more than four children shall be classified as a Group E occupancy. See Section 421 for special requirements for Group E child day care centers.

    Exception: Areas used for child day care purposes with a Residential Certificate, Family License or Family Group License may be located in a Group R-2 or R-3 occupancy as provided in Section 310.1 or shall comply with the International Residential Code in accordance with Section 101.2.

    Child day care centers providing care for more than 100 children 2 1/2 years or less of age shall be classified as Group I-4.

    (8) In Section 308 the following definitions are added:

    308.1.1 Definitions. The following words and terms shall, for the purposes of this section and as used elsewhere in this code, have the meanings shown herein.

    TYPE I ASSISTED LIVING FACILITY. A residential facility licensed by the Utah Department of Health that provides a protected living arrangement for ambulatory, non-restrained persons who are capable of achieving mobility sufficient to exit the facility without the assistance of another person.

    TYPE II ASSISTED LIVING FACILITY. A residential facility licensed by the Utah Department of Health that provides an array of coordinated supportive personal and health care services to residents who meet the definition of semi-independent.

    SEMI-INDEPENDENT. A person who is:

    A. Physically disabled but able to direct his or her own care; or

    B. Cognitively impaired or physically disabled but able to evacuate from the facility with the physical assistance of one person.

    RESIDENTIAL TREATMENT/SUPPORT ASSISTED LIVING FACILITY. A residential treatment/support assisted living facility which creates a group living environment for four or more residents licensed by the Utah Department of Human Services, and provides a protected living arrangement for ambulatory, non-restrained persons who are capable of achieving mobility sufficient to exit the facility without the physical assistance of another person.

    (9) Section 308.2 is deleted and replaced with the following:

    308.2 Group I-1. This occupancy shall include buildings, structures, or parts thereof housing more than 16 persons, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment that provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. This group shall include, but not be limited to, the following: residential board and care facilities, type I assisted living facilities, residential treatment/support assisted living facility, half-way houses, group homes, congregate care facilities, social rehabilitation facilities, alcohol and drug centers and convalescent facilities. A facility such as the above with five or fewer persons shall be classified as a Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2. A facility such as above, housing at least six and not more than 16 persons, shall be classified as a Group R-4.

    (10) Section 308.3 is deleted and replaced with the following:

    308.3 Group I-2. This occupancy shall include buildings and structures used for medical, surgical, psychiatric, nursing or custodial care on a 24-hour basis of more than three persons who are not capable of self-preservation. This group shall include, but not be limited to the following: hospitals, nursing homes (both intermediate care facilities and skilled nursing facilities), mental hospitals, detoxification facilities, ambulatory surgical centers with two or more operating rooms where care is less than 24 hours, outpatient medical care facilities for ambulatory patients (accommodating more than five such patients in each tenant space) which may render the patient incapable of unassisted self-preservation, and type II assisted living facilities. Type II assisted living facilities with five or fewer persons shall be classified as a Group R-4. Type II assisted living facilities as defined in 308.1.1 with at least six and not more than sixteen residents shall be classified as a Group I-1 facility.

    (11) Section 308.3.1 is deleted and replaced with the following:

    308.3.1 Child care facility. A child care facility that provides care on a 24 hour basis to more than four children 2 1/2 years of age or less shall be classified as Group I-2.

    (12) Section 308.5 is deleted and replaced with the following:

    308.5 Group I-4, day care facilities. This group shall include buildings and structures occupied by persons of any age who receive custodial care less than 24 hours by individuals other than parents or guardians, relatives by blood, marriage, or adoption, and in a place other than the home of the person cared for. A facility such as the above with four or fewer persons shall be classified as an R-3 or shall comply with the International Residential Code in accordance with Section 101.2. Places of worship during religious functions and Group E child day care centers are not included.

    (13) Section 308.5.2 is deleted and replaced with the following:

    308.5.2 Child care facility. A facility that provides supervision and personal care on less than a 24 hour basis for more than 100 children 2 1/2 years of age or less shall be classified as Group I-4.

    (14) Section 310.1 is deleted and replaced with the following:

    310.1 Residential Group "R". Residential Group R includes, among others, the use of a building or structure, or a portion thereof, for sleeping purposes when not classed as an Institutional Group I. Residential occupancies shall include the following:

    R-1: Residential occupancies where the occupants are primarily transient in nature (less than 30 days) including: Boarding Houses (transient) and congregate living facilities, Hotels (transient), and Motels (transient).

    Exception: Boarding houses and congregate living facilities accommodating 10 persons or less shall be classified as a Residential Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2.

    R-2: Residential occupancies containing sleeping units or more than two dwelling units where the occupants are primarily permanent in nature, including: Apartment Houses, Boarding houses (not transient) and congregate living facilities, Convents, Dormitories, Fraternities and Sororities, Monasteries, Vacation timeshare properties, Hotels (non transient), and Motels (non transient).

    Exception: Boarding houses and congregate living facilities accommodating 10 persons or less shall be classified as a Residential Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2.

    R-3: Residential occupancies where the occupants are primarily permanent in nature and not classified as R-1, R-2, R-4 or I and where buildings do not contain more than two dwelling units, as applicable in Section 101.2, or adult and child care facilities that provide accommodations for five or fewer persons of any age for less than 24 hours. Adult and child care facilities that are within a single family home are permitted to comply with the International Residential Code in accordance with Section 101.2. Areas used for day care purposes may be located in a residential dwelling unit under all of the following conditions:

    1. Compliance with the Utah Administrative Code, R710-8, Day Care Rules, as enacted under the authority of the Utah Fire Prevention Board.

    2. Use is approved by the State Department of Health, as enacted under the authority of the Utah Child Care Licensing Act, UCA, Sections 26-39-101 through 26-39-110, and in any of the following categories:

    a. Utah Administrative Code, R430-50, Residential Certificate Child Care Standards.

    b. Utah Administrative Code, R430-90, Licensed Family Child Care.

    3. Compliance with all zoning regulations of the local regulator.

    R-4: Residential occupancies shall include buildings arranged for occupancy as Residential Care/Assisted Living Facilities or Residential Treatment/Support Assisted Living Facilities including more than five but not more than 16 occupants, excluding staff.

    Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3 except as otherwise provided for in this code or shall comply with the International Residential Code in accordance with Section 101.2.

    (15) In Section 310.2 the definition for Residential Care/Assisted Living Facilities is deleted and replaced with the following:

    See Section 308.1.1.

    (16) A new section 421 is added as follows:

    Section 421 Group E Child Day Care Centers. Group E child day care centers shall comply with Section 421.

    421.1 Location at grade. Group E child day care centers shall be located at the level of exit discharge.

    Exception: Child day care spaces for children over the age of 24 months may be located on the second floor of buildings equipped with automatic fire protection throughout and an automatic fire alarm system.

    421.2 Egress. All Group E child day care spaces with an occupant load of more than 10 shall have a second means of egress. If the second means of egress is not an exit door leading directly to the exterior, the room shall have an emergency escape and rescue window complying with Section 1026.

    (17) In Section 707.14.1 Exception 4 is deleted.

    (18) In Section (F)902, the definition for record drawings is deleted and replaced with the following:

    (F)RECORD DRAWINGS. Drawings ("as builts") that document all aspects of a fire protection system as installed.

    (19) In Section (F)903.2.3 condition 2 is deleted and replaced with the following:

    2. Where a Group F-1 fire area is located more than three stories above the lowest level of fire department vehicle access; or

    (20) In Section (F)903.2.6 condition 2 is deleted and replaced with the following:

    2. Where a Group M fire area is located more than three stories above the lowest level of fire department vehicle access; or

    (21) Section (F)903.2.7 is deleted and replaced with the following:

    (F)903.2.7 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area.

    Exceptions:

    1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) constructed in accordance with the International Residential Code For One- and Two-Family Dwellings.

    2. Group R-4 fire areas not more than 4,500 gross square feet and not containing more than 16 residents, provided the building is equipped throughout with an approved fire alarm system that is interconnected and receives it primary power from the building wiring and a commercial power system.

    (22) In Section F903.2.8 condition 2 is deleted and replaced with the following:

    2. Where a Group S-1 fire area is located more than three stories above the lowest level of fire department vehicle access; or

    (23) Section (F)903.2.9 is deleted and replaced with the following:

    (F)903.2.9 Group S-2. An automatic sprinkler system shall be provided throughout buildings classified as parking garages in accordance with Section 406.2 or where located beneath other groups.

    Exception 1: Parking garages of less than 5,000 square feet (464 m2)accessory to Group R-3 occupancies.

    Exception 2: Open parking garages not located beneath other groups if one of the following conditions is met:

    a. Access is provided for fire fighting operations to within 150 feet (45,720 mm) of all portions of the parking garage as measured from the approved fire department vehicle access; or

    b. Class I standpipes are installed throughout the parking garage.

    (24) In Section (F)903.2.9.1 the last clause "where the fire area exceeds 5,000 square feet (464 m2)" is deleted.

    (25) Section (F)904.11 and Subsections (F)904.11.3, (F)904.11.3.1, (F)904.11.4 and (F)904.11.4.1 are deleted and replaced with the following:

    (F)904.11 Commercial cooking systems. The automatic fire-extinguishing system for commercial cooking systems shall be of a type recognized for protection of commercial cooking equipment and exhaust systems of the type and arrangement protected. Pre-engineered automatic extinguishing systems shall be tested in accordance with UL 300 and listed and labeled for the intended application. The system shall be installed in accordance with this code, its listing and the manufacturer's installation instructions. Automatic fire-extinguishing systems shall be installed in accordance with the referenced standard for wet-chemical extinguishing systems, NFPA 17A.

    Exception: Factory-built commercial cooking recirculating systems that are tested in accordance with UL 710B and listed, labeled and installed in accordance with Section 304.1 of the International Mechanical Code.

    (Subsections (F)904.11.1 and (F)904.11.2 remain unchanged.

    (26) Section (F)907.2.10 is deleted and replaced with the following:

    (F)907.2.10 Single- and multiple-station alarms. Listed single- and multiple-station smoke alarms complying with U.L. 217 shall be installed in accordance with the provision of this code and the household fire-warning equipment provision of NFPA 72. Listed single- and multiple-station carbon monoxide detectors shall comply with U.L. 2034 and shall be installed in accordance with the provisions of this code and NFPA 720.

    (F)907.2.10.1 Smoke alarms. Single- or multiple-station smoke alarms shall be installed in the locations described in Sections (F)907.2.10.1.1 through (F)907.2.10.1.3.

    (F)907.2.10.1.1 Group R-1. Single- or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1:

    1. In sleeping areas.

    2. In every room in the path of the means of egress from the sleeping area to the door leading from the sleeping unit.

    3. In each story within the sleeping unit, including basements. For sleeping units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.

    (F)907.2.10.1.2 Groups R-2, R-3, R-4 and I-1. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and I-1, regardless of occupant load at all of the following locations:

    1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.

    2. In each room used for sleeping purposes.

    3. In each story within a dwelling unit, including basements and cellars but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.

    (F)907.2.10.1.3 Group I-1. Single- or multiple-station smoke alarms shall be installed and maintained in sleeping areas in occupancies in Group I-1.

    Exception: Single- or multiple-station smoke alarms shall not be required where the building is equipped throughout with an automatic fire detection system in accordance with Section (F)907.2.6.

    (F)907.2.10.2 Carbon monoxide alarms. Carbon monoxide alarms shall be installed on each habitable level of a dwelling unit or sleeping unit in Groups R-2, R-3, R-4 and I-1 equipped with fuel burning appliances.

    (F)907.2.10.3. Power source. In new construction, required alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery backup. Alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection.

    Exception: Alarms are not required to be equipped with battery backup in Group R-1 where they are connected to an emergency electrical system.

    (F)907.2.10.4 Interconnection. Where more than one alarm is required to be installed with an individual dwelling unit in Group R-2, R-3, or R-4, or within an individual sleeping unit in Group R-1, the alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Approved combination smoke and carbon-monoxide detectors shall be permitted.

    (F)907.2.10.5 Acceptance testing. When the installation of the alarm devices is complete, each detector and interconnecting wiring for multiple-station alarm devices shall be tested in accordance with the household fire warning equipment provisions of NFPA 72 and NFPA 720, as applicable.

    (27) In Section 1007.3 a new exception 6 is added as follows:

    6. Areas of refuge are not required at exit stairways in buildings or facilities equipped throughout with an automatic fire sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2.

    (28) In Section 1007.4 the word "exception" is changed to "exception 1" and an exception 2 is added as follows:

    2. Elevators are not required to be accessed from an area of refuge or horizontal exit in buildings or facilities equipped throughout with an automatic fire sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2.

    (29) In Section 1008.1.8.3, a new subparagraph (5) is added as follows:

    (5) Doors in Group I-1 and I-2 occupancies, where the clinical needs of the patients require specialized security measures for their safety, approved access controlled egress may be installed when all the following are met:

    5.1 The controlled egress doors shall unlock upon activation of the automatic fire sprinkler system or automatic fire detection system.

    5.2 The facility staff can unlock the controlled egress doors by either sensor or keypad.

    5.3 The controlled egress doors shall unlock upon loss of power.

    (30) In Section 1009.3, Exception #4 is deleted and replaced with the following:

    4. In Group R-3 occupancies, within dwelling units in Group R-2 occupancies, and in Group U occupancies that are accessory to a Group R-3 occupancy, or accessory to individual dwelling units in Group R-2 occupancies, the maximum riser height shall be 8 inches (203 mm) and the minimum tread depth shall be 9 inches (229 mm). The minimum winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum winder tread depth shall be 6 inches (152 mm). A nosing not less than 0.75 inch (19.1 mm) but not more than 1.25 inches (32 mm) shall be provided on stairways with solid risers where the tread depth is less than 10 inches (254 mm).

    (31) In Section 1009.10 Exception 6 is added as follows:

    6. In occupancies in Group R-3, as applicable in Section 101.2 and in occupancies in Group U, which are accessory to an occupancy in Group R-3, as applicable in Section 101.2, handrails shall be provided on at least one side of stairways consisting of four or more risers.

    (32) Section 1012.3 is amended to include the following exception at the end of the section:

    Exception. Non-circular handrails serving an individual unit in a Group R-1, Group R-2 or Group R-3 occupancy with a perimeter greater than 6 1/4 inches (160 mm) shall provide a graspable finger recess area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest portion of the profile. This required depth shall continue for at least 3/8 inch (10 mm) to a level that is not less than 1 3/4 inches (45 mm) below the tallest portion of the profile. The minimum width of the handrail above the recess shall be 1 1/4 inches (32 mm) to a maximum of 2 3/4 inches (70 mm). Edges shall have a minimum radius of 0.01 inch (0.25 mm).

    (33) In Section 1013.2 Exception 3 is added as follows:

    3. For occupancies in Group R-3 and within individual dwelling units in occupancies in Group R-2, as applicable in Section 101.2, guards shall form a protective barrier not less than 36 inches (914 mm) in height.

    (34) In Section 1015.2.2 the following sentence is added at the end:

    Additional exits or exit access doorways shall be arranged a reasonable distance apart so that if one becomes blocked, the others will be available.

    (35) A new Section 1109.7.1 is added as follows:

    1109.7.1 Platform (wheelchair) lifts. All platform (wheelchair) lifts shall be capable of independent operation without a key.

    (36) In Section 1208.4 subparagraph 1 is deleted and replaced with the following:

    1. The unit shall have a living room of not less than 165 square feet (15.3 m2) of floor area. An additional 100 square feet (9.3 m2) of floor area shall be provided for each occupant of such unit in excess of two.

    (37) Section 1405.3 is deleted and replaced with the following:

    1405.3 Flashing. Flashing shall be installed in such a manner so as to prevent moisture from entering the wall or to redirect it to the exterior. Flashings shall be installed at the perimeters of exterior door and window assemblies, penetrations and terminations of exterior wall assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies and similar projections and at built-in gutters and similar locations where moisture could enter the wall. Flashing with projected flanges shall be installed on both sides and the ends of copings, under sills and continuously above projected trim. A flashing shall be installed at the intersection of the foundation to stucco, masonry, siding or brick veneer. The flashing shall be on an approved corrosion-resistant flashing with a 1/2" drip leg extending past exterior side of the foundation.

    (38) In Section 1605.2.1, the formula shown as "f2 = 0.2 for other roof configurations" is deleted and replaced with the following:

    f2 = 0.20 + .025(A-5) for other configurations where roof snow load exceeds 30 psf

    f2 = 0 for roof snow loads of 30 psf (1.44kN/m2) or less.

    Where A = Elevation above sea level at the location of the structure (ft/1000).

    (39) In Section 1605.3.1 and section 1605.3.2, Exception number 2 in each section is deleted and replaced with the following:

    2. Flat roof snow loads of 30 pounds per square foot (1.44 kNm2) or less need not be combined with seismic loads. Where flat roof snow loads exceed 30 pounds per square foot (1.44 kNm2), the snow loads may be reduced in accordance with the following in load combinations including both snow and seismic loads. Ws as calculated below, shall be combined with seismic loads.

    Ws = (0.20 + 0.025(A-5))Pf is greater than or equal to 0.20 Pf

    Where

    Ws = Weight of snow to be included in seismic calculations;

    A = Elevation above sea level at the location of the structure (ft/1000)

    Pf = Design roof snow load, psf

    For the purpose of this section, snow load shall be assumed uniform on the roof footprint without including the effects of drift or sliding. The Importance Factor, I, used in calculating Pf may be considered 1.0 for use in the formula for Ws.

    (40) In Table 1607.1 number 9 is deleted and replaced with the following:

     

    TABLE 1607.1 NUMBER 9

    Occupancy or Use                     Uniform    Concentrated
    (psf) (lbs)
    9. Decks, except residential Same as occupancy
    servedh
    9.1 Residential decks 60 psf

     

    (41) Section 1608.1 is deleted and replaced with the following:

    1608.1 General. Except as modified in section 1608.1.1, 1608.1.2, and 1608.1.3 design snow loads shall be determined in accordance with Section 7 of ASCE 7, but the design roof load shall not be less than that determined by Section 1607.

    (42) Section 1608.1.1 is added as follows:

    1608.1.1 Section 7.4.5 of Section 7 of ASCE 7 referenced in Section 1608.1 of the IBC is deleted and replaced with the following:

    Section 7.4.5 Ice Dams and Icicles Along Eaves. Where ground snow loads exceed 75 psf, eaves shall be capable of sustaining a uniformly distributed load of 2pf on all overhanging portions. No other loads except dead loads shall be present on the roof when this uniformly distributed load is applied. All building exits under down-slope eaves shall be protected from sliding snow and ice.

    (43) Section 1608.1.2 is added as follows:

    1608.1.2 Utah Snow Loads. The ground snow load, Pg, to be used in the determination of design snow loads for buildings and other structures shall be determined by using the following formula: Pg = (Po2 + S2(A-Ao)2)0.5 for A greater than Ao, and Pg = Po for A less than or equal to Ao.

    WHERE

    Pg = Ground snow load at a given elevation (psf)

    Po = Base ground snow load (psf) from Table No. 1608.1.2(a)

    S = Change in ground snow load with elevation (psf/100 ft.) From Table No. 1608.1.2(a)

    A = Elevation above sea level at the site (ft./1000)

    Ao = Base ground snow elevation from Table 1608.1.2(a) (ft./1000)

    The building official may round the roof snow load to the nearest 5 psf. The ground snow load, Pg, may be adjusted by the building official when a licensed engineer or architect submits data substantiating the adjustments. A record of such action together with the substantiating data shall be provided to the division for a permanent record.

    The building official may also directly adopt roof snow loads in accordance with Table 1608.1.2(b), provided the site is no more than 100 ft. higher than the listed elevation.

    Where the minimum roof live load in accordance with section 1607.11 is greater than the design roof snow load, such roof live load shall be used for design, however, it shall not be reduced to a load lower than the design roof snow load. Drifting need not be considered for roof snow loads less than 20 psf.

    (44) Table 1608.1.2(a) and Table 1608.1.2(b) are added as follows:

     

    TABLE NO. 1608.1.2(a)
    STATE OF UTAH - REGIONAL SNOW LOAD FACTORS

         COUNTY       Po     S     Ao

    Beaver 43 63 6.2
    Box Elder 43 63 5.2
    Cache 50 63 4.5
    Carbon 43 63 5.2
    Daggett 43 63 6.5
    Davis 43 63 4.5
    Duchesne 43 63 6.5
    Emery 43 63 6.0
    Garfield 43 63 6.0
    Grand 36 63 6.5
    Iron 43 63 5.8
    Juab 43 63 5.2
    Kane 36 63 5.7
    Millard 43 63 5.3
    Morgan 57 63 4.5
    Piute 43 63 6.2
    Rich 57 63 4.1
    Salt Lake 43 63 4.5
    San Juan 43 63 6.5
    Sanpete 43 63 5.2
    Sevier 43 63 6.0
    Summit 86 63 5.0
    Tooele 43 63 4.5
    Uintah 43 63 7.0
    Utah 43 63 4.5
    Wasatch 86 63 5.0
    Washington 29 63 6.0
    Wayne 36 63 6.5
    Weber 43 63 4.5

    TABLE NO. 1608.1.2(b)
    RECOMMENDED SNOW LOADS FOR SELECTED UTAH CITIES AND TOWNS(2)

                                      Roof Snow      Ground Snow
    Load (PSF) Load (PSF)

    Beaver County
    Beaver 5920 ft. 43 62
    Box Elder County
    Brigham City 4300 ft. 30 43
    Tremonton 4290 ft. 30 43
    Cache County
    Logan 4530 ft. 35 50
    Smithfield 4595 ft. 35 50
    Carbon County
    Price 5550 ft. 30 43
    Daggett County
    Manila 5377 ft. 30 43
    Davis County
    Bountiful 4300 ft. 30 43
    Farmington 4270 ft. 30 43
    Layton 4400 ft. 30 43
    Fruit Heights 4500 ft. 40 57
    Duchesne County
    Duchesne 5510 ft. 30 43
    Roosevelt 5104 ft. 30 43
    Emery County
    Castledale 5660 ft. 30 43
    Green River 4070 ft. 25 36
    Garfield County
    Panguitch 6600 ft. 30 43
    Grand County
    Moab 3965 ft. 25 36
    Iron County
    Cedar City 5831 ft. 30 43
    Juab County
    Nephi 5130 ft. 30 43
    Kane County
    Kanab 5000 ft. 25 36
    Millard County
    Millard 5000 ft. 30 43
    Delta 4623 ft. 30 43
    Morgan County
    Morgan 5064 ft. 40 57
    Piute County
    Piute 5996 ft. 30 43
    Rich County
    Woodruff 6315 ft. 40 57
    Salt Lake County
    Murray 4325 ft. 30 43
    Salt Lake City 4300 ft. 30 43
    Sandy 4500 ft. 30 43
    West Jordan 4375 ft. 30 43
    West Valley 4250 ft. 30 43
    San Juan County
    Blanding 6200 ft. 30 43
    Monticello 6820 ft. 35 50
    Sanpete County
    Fairview 6750 ft. 35 50
    Mt. Pleasant 5900 ft. 30 43
    Manti 5740 ft. 30 43
    Ephraim 5540 ft. 30 43
    Gunnison 5145 ft. 30 43
    Sevier County
    Salina 5130 ft. 30 43
    Richfield 5270 ft. 30 43
    Summit County
    Coalville 5600 ft. 60 86
    Kamas 6500 ft. 70 100
    Park City 6800 ft. 100 142
    Park City 8400 ft. 162 231
    Summit Park 7200 ft. 90 128
    Tooele County
    Tooele 5100 ft. 30 43
    Uintah County
    Vernal 5280 ft. 30 43
    Utah County
    American Fork 4500 ft. 30 43
    Orem 4650 ft. 30 43
    Pleasant Grove 5000 ft. 30 43
    Provo 5000 ft. 30 43
    Spanish Fork 4720 ft. 30 43
    Wasatch County
    Heber 5630 ft. 60 86
    Washington County
    Central 5209 ft. 25 36
    Dameron 4550 ft. 25 36
    Leeds 3460 ft. 20 29
    Rockville 3700 ft. 25 36
    Santa Clara 2850 ft. 15 (1) 21
    St. George 2750 ft. 15 (1) 21
    Wayne County
    Loa 7080 ft. 30 43
    Hanksville 4308 ft. 25 36
    Weber County
    North Ogden 4500 ft. 40 57
    Ogden 4350 ft. 30 43

    NOTES
    (1) The IBC requires a minimum live load - See 1607.11.2.
    (2) This table is informational only in that actual site
    elevations may vary. Table is only valid if site elevation is
    within 100 feet of the listed elevation.

     

    (45) Section 1608.1.3 is added as follows:

    1608.1.3 Thermal Factor. The value for the thermal factor, Ct, used in calculation of pf shall be determined from Table 7.3 in ASCE 7.

    Exception: Except for unheated structures, the value of Ct need not exceed 1.0 when ground snow load, Pg is calculated using Section 1608.1.2 as amended.

    (46) Section 1608.2 is deleted and replaced with the following:

    1608.2 Ground Snow Loads. The ground snow loads to be used in determining the design snow loads for roofs in states other than Utah are given in Figure 1608.2 for the contiguous United States and Table 1608.2 for Alaska. Site-specific case studies shall be made in areas designated CS in figure 1608.2. Ground snow loads for sites at elevations above the limits indicated in Figure 1608.2 and for all sites within the CS areas shall be approved. Ground snow load determination for such sites shall be based on an extreme value statistical analysis of data available in the vicinity of the site using a value with a 2-percent annual probability of being exceeded (50-year mean recurrence interval). Snow loads are zero for Hawaii, except in mountainous regions as approved by the building official.

    (47) In Section 1609.1.1 a new exception number 5 is added as follows:

    5. The wind design procedure as found in Section 1616 through 1624 of the 1997 Uniform Building Code may be used as an alternative wind design procedure for:

    (a) items 1 through 3 listed in Table 16-H of the 1997 Uniform Building Code provided that the building or component being designed meets the limits for the Simplified Method as defined in ASCE 6.4.1.1 and 6.4.1.2 of ASCE 7; or

    (b) items 4 through 7 listed in Table 16-H of the 1997 Uniform Building Code.

    The Importance Factor, I, shall be determined in accordance with Table 6-1 of ASCE 7.

    (48) Section 1613.7 is added as follows:

    1613.7 ASCE 12.7.2 and 12.14.18.1 of Section 12 of ASCE 7 referenced in Section 1613.1, Definition of W, Item 4 is deleted and replaced with the following:

    4. Where the flat roof snow load, Pf, exceeds 30 psf, the snow load included in seismic design shall be calculated, in accordance with the following formula: Ws = (0.20 + 0.025(A-5))Pf is greater than or equal to 0.20 Pf

    WHERE:

    Ws = Weight of snow to be included in seismic calculations;

    A = Elevation above sea level at the location of the structure (ft/1000)

    Pf = Design roof snow load, psf

    For the purposes of this section, snow load shall be assumed uniform on the roof footprint without including the effects of drift or sliding. The Importance Factor, I, used in calculating Pf may be considered 1.0 for use in the formula for Ws.

    (49) A new Section 1613.8 is added as follows:

    1613.8 ASCE 7, Section 13.5.6.2.2 paragraph (e) is modified to read as follows:

    (e) Penetrations shall have a sleeve or adapter through the ceiling tile to allow for free movement of at least 1 inch (25 mm) in all horizontal directions.

    Exceptions:

    1. Where rigid braces are used to limit lateral deflections.

    2. At fire sprinkler heads in frangible surfaces per NFPA 13.

    (50) Section 1805.5 is deleted and replaced with the following:

    1805.5 Foundation walls. Concrete and masonry foundation walls shall be designed in accordance with Chapter 19 or 21, respectively. Foundation walls that are laterally supported at the top and bottom and within the parameters of Tables 1805.5(1) through 1805.5(5) are permitted to be designed and constructed in accordance with Sections 1805.5.1 through 1805.5.5. Concrete foundation walls may also be constructed in accordance with Section 1805.5.8.

    (51) A new section 1805.5.8 is added as follows:

    1805.5.8 Empirical foundation design. Group R, Division 3 Occupancies three stories or less in height, and Group U Occupancies, which are constructed in accordance with Section 2308, or with other methods employing repetitive wood-frame construction or repetitive cold-formed steel structural member construction, shall be permitted to have concrete foundations constructed in accordance with Table 1805.5(6).

    (52) Table 1805.5(6) is added as follows:

    Table 1805.5(6), entitled "Empirical Foundation Walls, dated January 1, 2007, published by the Department of Commerce, Division of Occupational and Professional Licensing is hereby adopted and incorporated by reference. Table 1805.5(6) identifies foundation requirements for empirical walls.

    (53) A new section 2306.1.5 is added as follows:

    2306.1.5 Load duration factors. The allowable stress increase of 1.15 for snow load, shown in Table 2.3.2, Frequently Used Load Duration Factors, Cd, of the National Design Specifications, shall not be utilized at elevations above 5,000 feet (1524 M).

    (54) In Section 2308.6 the following exception is added:

    Exception: Where foundation plates or sills are bolted or anchored to the foundation with not less than 1/2 inch (12.7 mm) diameter steel bolts or approved anchors, embedded at least 7 inches (178 mm) into concrete or masonry and spaced not more than 32 inches (816 mm) apart, there shall be a minimum of two bolts or anchor straps per piece located not less than 4 inches (102 mm) from each end of each piece. A properly sized nut and washer shall be tightened on each bolt to the plate.

    (55) Section 2506.2.1 is deleted and replaced with the following:

    2506.2.1 Other materials. Metal suspension systems for acoustical and lay-in panel ceilings shall conform with ASTM C635 listed in Chapter 35 and Section 13.5.6 of ASCE 7-05, as amended in Section 1613.8, for installation in high seismic areas.

    (56) In Section 2902.1, the title for Table 2902.1 is deleted and replaced with the following and footnote e is added as follows: Table 2902.1, Minimum Number of Required Plumbing Facilitiesa, e.

    FOOTNOTE: e. When provided, in public toilet facilities there shall be an equal number of diaper changing facilities in male toilet rooms and female toilet rooms.

    (57) Section 3006.5 Shunt Trip, the following exception is added:

    Exception: Hydraulic elevators and roped hydraulic elevators with a rise of 50 feet or less.

    (58) A new section 3403.2.4 is added as follows:

    3403.2.4 Parapet bracing, wall anchors, and other appendages. Buildings constructed prior to 1975 shall have parapet bracing, wall anchors, and appendages such as cornices, spires, towers, tanks, signs, statuary, etc. evaluated by a licensed engineer when said building is undergoing reroofing, or alteration of or repair to said feature. Such parapet bracing, wall anchors, and appendages shall be evaluated in accordance with 75% of the seismic forces as specified in Section 1613. When allowed by the local building official, alternate methods of equivalent strength as referenced in Subsection R156-56-701(2) will be considered when accompanied by engineer sealed drawings, details and calculations. When found to be deficient because of design or deteriorated condition, the engineer's [shall prepare specific ]recommendations to anchor, brace, reinforce, or remove the deficient feature shall be implemented.

    EXCEPTIONS:

    1. Group R-3 and U occupancies.

    2. Unreinforced masonry parapets need not be braced according to the above stated provisions provided that the maximum height of an unreinforced masonry parapet above the level of the diaphragm tension anchors or above the parapet braces shall not exceed one and one-half times the thickness of the parapet wall. The parapet height may be a maximum of two and one-half times its thickness in other than Seismic Design Categories D, E, or F.

    (59) Section 3406.4 is deleted and replaced with the following:

    3406.4 Change in Occupancy. When a change in occupancy results in a structure being reclassified to a higher Occupancy Category (as defined in Table 1604.5), or when such change of occupancy results in a design occupant load increase of 100% or more, the structure shall conform to the seismic requirements for a new structure.

    Exceptions:

    1. Specific seismic detailing requirements of this code or ASCE 7 for a new structure shall not be required to be met where it can be shown that the level of performance and seismic safety is equivalent to that of a new structure. Such analysis shall consider the regularity, overstrength, redundancy and ductility of the structure within the context of the existing and retrofit (if any) detailing providing. Alternatively, the building official may allow the structure to be upgraded in accordance with referenced sections as found in Subsection R156-56-701(2).

    2. When a change of use results in a structure being reclassified from Occupancy Category I or II to Occupancy Category III and the structure is located in a seismic map area where SDS is less than 0.33, compliance with the seismic requirements of this code and ASCE 7 are not required.

    3. Where design occupant load increase is less than 25 occupants and the Occupancy Category does not change.

    (60) The exception in 3409.1 is deleted and replaced with the following:

    Exception: Type B dwelling or sleeping units required by section 1107 are not required to be provided in existing buildings and facilities, except when an existing occupancy is changed to R-2.

    (61) In Section 3409.4, number 7 is added as follows:

    7. When a change of occupancy in a building or portion of a building results in a Group R-2 occupancy as determined in section 1107.6.2, not less than 20 percent of the dwelling or sleeping units shall be Type B dwelling or sleeping units. These dwelling or sleeping units may be located on any floor of the building provided with an accessible route. Two percent, but not less than one, of the dwelling or sleeping units shall be Type A dwelling units.

    (62) The following referenced standard is added under NFPA in chapter 35:

     

    TABLE

                                                  Referenced in code
    Number Title Section number
    720-05 Recommended Practice for the 907.2.10, 907.2.10.5
    Installation of Household Carbon
    Monoxide (CO) Warning Equipment

     

    R156-56-803. Statewide Amendments to the IPC.

    The following are adopted as amendments to the IPC to be applicable statewide:

    (1) In Section 202, the definition for "Backflow Backpressure, Low Head" is deleted in its entirety.

    (2) In Section 202, the definition for "Backsiphonage" is deleted and replaced with the following:

    Backsiphonage. The backflow of potentially contaminated, polluted or used water into the potable water system as a result of the pressure in the potable water system falling below atmospheric pressure of the plumbing fixtures, pools, tanks or vats connected to the potable water distribution piping.

    (3) In Section 202, the following definition is added:

    Certified Backflow Preventer Assembly Tester. A person who has shown competence to test Backflow prevention assemblies to the satisfaction of the authority having jurisdiction under Subsection 19-4-104(4), Utah Code Ann. (1953), as amended.

    (4) In Section 202, the definition for "Cross Connection" is deleted and replaced with the following:

    Cross Connection. Any physical connection or potential connection or arrangement between two otherwise separate piping systems, one of which contains potable water and the other either water of unknown or questionable safety or steam, gas or chemical, whereby there exists the possibility for flow from one system to the other, with the direction of flow depending on the pressure differential between the two systems (see "Backflow").

    (5) In Section 202, the following definition is added:

    Heat Exchanger (Potable Water). A device to transfer heat between two physically separated fluids (liquid or steam), one of which is potable water.

    (6) In Section 202, the definition for "Potable Water" is deleted and replaced with the following:

    Potable Water. Water free from impurities present in amounts sufficient to cause disease or harmful physiological effects and conforming to the Titles 19-4 and 19-5, Utah Code Ann. (1953), as amended and the regulations of the public health authority having jurisdiction.

    (7) In Section 202, the following definition is added:

    S-Trap. A trap having its weir installed above the inlet of the vent connection.

    (8) In Section 202, the definition for "Water Heater" is deleted and replaced with the following:

    Water Heater. A closed vessel in which water is heated by the combustion of fuels or electricity and is withdrawn for use external to the system at pressures not exceeding 160 psig (1100 kPa (gage)), including the apparatus by which heat is generated, and all controls and devices necessary to prevent water temperatures from exceeding 210 degrees Fahrenheit (99 degrees Celsius).

    (9) Section 304.3 Meter Boxes is deleted.

    (10) Section 305.5 is deleted and replaced with the following:

    305.5 Pipes through or under footings or foundation walls. Any pipe that passes under or through a footing or through a foundation wall shall be protected against structural settlement.

    (11) Section 305.8 is deleted and replaced with the following:

    305.8 Protection against physical damage. In concealed locations where piping, other than cast-iron or galvanized steel, is installed through holes or notches in studs, joists, rafters or similar members less than 1 1/2 inches (38 mm) from the nearest edge of the member, the pipe shall be protected by shield plates. Protective shield plates shall be minimum of 1/16 inch-thick (1.6 mm) steel, shall cover the area of the pipe where the member is notched or bored, and shall be at least the thickness of the framing member penetrated.

    (12) Section 305.10 is added as follows:

    Section 305.10 Improper Connections. No drain, waste, or vent piping shall be drilled and tapped for the purpose of making connections.

    (13) Section 311.1 is deleted.

    (14) Section 312.9 is deleted in its entirety and replaced with the following:

    312.9 Backflow assembly testing. The premise owner or his designee shall have backflow prevention assemblies operation tested at the time of installation, repair and relocation and at least on an annual basis thereafter, or more frequently as required by the authority having jurisdiction. Testing shall be performed by a Certified Backflow Preventer Assembly Tester. The assemblies that are subject to this paragraph are the Spill Resistant Vacuum Breaker, the Pressure Vacuum Breaker Assembly, the Double Check Backflow Prevention Assembly, the Double Check Detector Assembly Backflow Preventer, the Reduced Pressure Principle Backflow Preventer, and Reduced Pressure Detector Assembly.

    (15) In Section 403.1 footnote e is added as follows:

    FOOTNOTE: e. When provided, in public toilet facilities there shall be an equal number of diaper changing facilities in male toilet rooms and female toilet rooms.

    (16) In Section 406.3, an exception is added as follows:

    Exception: Gravity discharge clothes washers, when properly trapped and vented, shall be allowed to be directly connected to the drainage system or indirectly discharge into a properly sized catch basin, trench drain, or other approved indirect waste receptor installed for the purpose of receiving such waste.

    (17) A new section 406.4 is added as follows:

    406.4 Automatic clothes washer metal safe pans. Metal safe pans, when installed under automatic clothes washers, shall only be allowed to receive the unintended discharge from a leaking appliance, valve, supply hose, or overflowing waste water from the clothes washer standpipe. Clothes washer metal safe pans shall not be used as indirect waste receptors to receive the discharge of waste water from any other equipment, appliance, appurtenance, drain pipe, etc. Each safe pan shall be provided with an approved trap seal primer, conforming to ASSE 1018 or 1044 or a deep seal trap. The sides of the safe pan shall be no less than 1 1/2" high and shall be soldered at the joints to provide a water tight seal.

    406.4.1 Safe pan outlet. The safe pan outlet shall be no less than 1 1/2" in diameter and shall be located in a visible and accessible location to facilitate cleaning and maintenance. The outlet shall be flush with the surface of the pan so as not to allow water retention within the pan.

    (18) Section 412.1 is deleted and replaced with the following:

    412.1 Approval. Floor drains shall be made of ABS, PVC, cast-iron, stainless steel, brass, or other approved materials that are listed for the use.

    (19) Section 412.5 is added as follows:

    412.5 Public toilet rooms. All public toilet rooms shall be equipped with at least one floor drain.

    (20) Section 418.1 is deleted and replaced with the following:

    418.1 Approval. Sinks shall conform to ANSI Z124.6, ASME A112.19.1M, ASME A112.19.2M, ASME A112.19.3M, ASME A112.19.4M, ASME A112.19.9M, CSA B45.1, CSA B45.2, CSA B45.3, CSA B45.4 or NSF 2.

    (21) Section 504.6.2 is deleted and replaced with the following:

    504.6.2 Material. Relief valve discharge piping shall be of those materials listed in Tables 605.4 and 605.5 and meet the requirements for Sections 605.4 and 605.5 or shall be tested, rated and approved for such use in accordance with ASME A112.4.1. Piping from safety pan drains shall meet the requirements of Section 804.1 and be constructed of those materials listed in Section 702.

    (22) Section 504.7.2 is deleted and replaced with the following:

    504.7.2 Pan drain termination. The pan drain shall extend full-size and terminate over a suitably located indirect waste receptor, floor drain or extend to the exterior of the building and terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. When permitted by the administrative authority, the pan drain may be directly connected to a soil stack, waste stack, or branch drain. The pan drain shall be individually trapped and vented as required in Section 907.1. The pan drain shall not be directly or indirectly connected to any vent. The trap shall be provided with a trap primer conforming to ASSE 1018 or ASSE 1044.

    (23) A new section 504.7.3 is added as follows:

    504.7.3 Pan Designation. A water heater pan shall be considered an emergency receptor designated to receive the discharge of water from the water heater only and shall not receive the discharge from any other fixtures, devises or equipment.

    (24) Section 602.3 is deleted and replaced with the following:

    602.3 Individual water supply. Where a potable public water supply is not available, individual sources of potable water supply shall be utilized provided that the source has been developed in accordance with Sections 73-3-1, 73-3-3, and 73-3-25, Utah Code Ann. (1953), as amended, as administered by the Department of Natural Resources, Division of Water Rights. In addition, the quality of the water shall be approved by the local health department having jurisdiction. The source shall supply sufficient quantity of water to comply with the requirements of this chapter.

    (25) Sections 602.3.1, 602.3.2, 602.3.3, 602.3.4, 602.3.5 and 602.3.5.1 are deleted in their entirety.

    (26) Section 604.4.1 is added as follows:

    604.4.1 Metering faucets. Self closing or metering faucets shall provide a flow of water for at least 15 seconds without the need to reactivate the faucet.

    (27) Section 606.5 is deleted and replaced with the following:

    606.5 Water pressure booster systems. Water pressure booster systems shall be provided as required by Section 606.5.1 through 606.5.11.

    (28) Section 606.5.11 is added as follows:

    606.5.11 Prohibited installation. In no case shall a booster pump be allowed that will lower the pressure in the public main to less than 20 psi.

    (29) In Section 608.1, the following sentence is added at the end of the paragraph:

    Connection without an air gap between potable water piping and sewer-connected waste shall not exist under any condition.

    (30) Table 608.1 is deleted and replaced with the following:

     

    TABLE 608.1
    General Methods of Protection

    Assembly     Degree     Application     Installation Criteria
    (applicable of
    standard) Hazard
    Air Gap High or Backsiphonage See Table 608.15.1
    (ASME A112.1.2) Low

    Reduced High or Backpressure or a. The bottom of each
    Pressure Low Backsiphonage RP assembly shall
    Principle Backflow 1/2" - 16" be a minimum of 12
    Preventer (AWWA inches above the
    C511, USC-FCCCHR, ground or floor.
    ASSE 1013 b. RP assemblies shall
    CSA CNA/CSA-B64.4) NOT be installed in
    and Reduced Pressure a pit.
    Detector Assembly c. The relief valve on
    (ASSE 1047, USC- each RP assembly
    FCCCHR) shall not be
    directly connected
    to any waste
    disposal line,
    including sanitary
    sewer, storm drains,
    or vents.
    d. The assembly shall
    be installed in a
    horizontal position
    only unless listed
    or approved for
    vertical
    installation.

    Double Check Low Backpressure or a. If installed in a
    Backflow Backsiphonage pit, the DC assembly
    Prevention 1/2" - 16" shall be installed
    Assembly with a minimum of
    (AWWA C510, 12 inches of
    USC-FCCCHR, clearance between
    ASSE 1015) all sides of the
    Double Check vault including
    Detector Assembly the floor and roof
    Backflow Preventer or ceiling with
    (ASSE 1048, adequate room for
    USC-FCCCHR) testing and
    maintenance.
    b. Shall be installed
    in a horizontal
    position unless
    listed or approved
    for vertical
    installation.

    Pressure High or Backsiphonage a. Shall not be
    Vacuum Low 1/2" - 2" installed in an
    Breaker area that could be
    Assembly subjected to
    (ASSE 1020, backpressure or
    USC-FCCCHR) back drainage
    conditions.
    b. Shall be installed
    a minimum of 12
    inches above all
    downstream piping
    and the highest
    point of use.
    c. Shall not be
    installed below
    ground or in a
    vault or pit.
    d. Shall be installed
    in a vertical
    position only.

    Spill High or Backsiphonage a. Shall not be
    Resistant Low 1/4" - 2" installed in an
    Vacuum area that could
    Breaker be subjected to
    (ASSE 1056, backpressure or
    USC-FCCCHR) back drainage
    conditions.
    b. Shall be installed
    a minimum of 12
    inches above all
    downstream piping
    and the highest
    point of use.
    c. Shall not be
    installed below
    ground or in a
    vault or pit.
    d. Shall be installed
    in a vertical
    position only.

    Atmospheric High or Backsiphonage a. Shall not be
    Vacuum Low installed in an
    Breaker area that could be
    (ASSE 1001 subjected to
    USC-FCCCHR, backpressure or back
    CSA CAN/CSA-B64.1.1 drainage conditions.
    b. Shall not be
    installed where it
    may be subjected to
    continuous pressure
    for more than 12
    consecutive hours
    at any time.
    c. Shall be installed
    a minimum of six
    inches above all
    downstream piping
    and the highest
    point of use.
    d. Shall be installed
    on the discharge
    (downstream) side
    of any valves.
    e. The AVB shall be
    installed in a
    vertical position
    only.

    General The assembly owner,
    Installation when necessary,
    Criteria shall provide
    devices or
    structures to
    facilitate testing,
    repair, and/or
    maintenance and to
    insure the safety
    of the backflow
    technician.
    Assemblies shall
    not be installed
    more than five feet
    off the floor unless
    a permanent platform
    is installed.

    The body of the
    assembly shall not
    be closer than 12
    inches to any wall,
    ceiling or
    incumbrance, and
    shall be accessible
    for testing, repair
    and/or maintenance.

    In cold climates,
    assemblies shall be
    protected from
    freezing by a means
    acceptable to the
    code official.

    Assemblies shall
    be maintained as
    an intact assembly.

     

    (31) Table 608.1.1 is added as follows:

     

    TABLE 608.1.1

    Specialty Backflow Devices for low hazard use only

    Device Degree of Application Applicable
    Hazard Standard

    Antisiphon-type Low Backsiphonage ASSE 1002
    Water Closet Flush CSA CAN/
    Tank Ball Cock CSA-B125

    Dual check valve Low Backsiphonage ASSE 1024
    Backflow Preventer or Backpressure
    1/4" - 1"

    Backflow Preventer Low Backsiphonage ASSE 1012
    with Intermediate Residential or Backpressure CSA CAN/
    Atmospheric Vent Boiler 1/4" - 3/4" CSA-B64.3

    Dual check valve Low Backsiphonage ASSE 1022
    type Backflow or Backpressure
    Preventer for 1/4" - 3/8"
    Carbonated Beverage
    Dispensers/Post
    Mix Type

    Hose-connection Low Backsiphonage ASSE 1011
    Vacuum Breaker 1/2", 3/4", 1" CSA CAN/
    CSA-B64.2

    Vacuum Breaker Low Backsiphonage ASSE 1019
    Wall Hydrants, 3/4", 1" CSA CAN/
    Frost-resistant, CSA-B64.2.2
    Automatic Draining
    Type

    Laboratory Faucet Low Backsiphonage ASSE 1035
    Backflow Preventer CSA CAN/
    CSA-B64.7

    Hose Connection Low Backsiphonage ASSE 1052
    Backflow Preventer 1/2" - 1"
    Installation Guidelines: The above specialty devices shall be
    installed in accordance with their listing and the manufacturer's
    instructions and the specific provisions of this chapter.

     

    (32) In Section 608.3.1, the following sentence is added at the end of the paragraph:

    All piping and hoses shall be installed below the atmospheric vacuum breaker.

    (33) Section 608.7 is deleted in its entirety.

    (34) In Section 608.8, the following sentence is added at the end of the paragraph:

    In addition each nonpotable water outlet shall be labeled with the words "CAUTION: UNSAFE WATER, DO NOT DRINK".

    (35) In Section 608.11, the following sentence is added at the end of the paragraph:

    The coating shall conform to NSF Standard 61 and application of the coating shall comply with the manufacturers instructions.

    (36) Section 608.13.3 is deleted and replaced with the following:

    608.13.3 Backflow preventer with intermediate atmospheric vent. Backflow preventers with intermediate atmospheric vents shall conform to ASSE 1012 or CAS CAN/CAS-B64.3. These devices shall be permitted to be installed on residential boilers only where subject to continuous pressure conditions. The relief opening shall discharge by air gap and shall be prevented from being submerged.

    (37) Section 608.13.4 is deleted in its entirety.

    (38) Section 608.13.9 is deleted in its entirety.

    (39) Section 608.15.3 is deleted and replaced with the following:

    608.15.3 Protection by a backflow preventer with intermediate atmospheric vent. Opening and outlets to residential boilers only shall be protected by a backflow preventer with an intermediate atmospheric vent.

    (40) Section 608.15.4 is deleted and replaced with the following:

    608.15.4 Protection by a vacuum breaker. Openings and outlets shall be protected by atmospheric-type or pressure-type vacuum breakers. The critical level of the atmospheric vacuum breaker shall be set a minimum of 6 inches (152 mm) above the flood level rim of the fixture or device. The critical level of the pressure vacuum breaker shall be set a minimum of 12 inches (304 mm) above the flood level rim of the fixture or device. Ball cocks shall be set in accordance with Section 425.3.1. Vacuum breakers shall not be installed under exhaust hoods or similar locations that will contain toxic fumes or vapors. Pipe-applied vacuum breakers shall be installed not less than 6 inches (152 mm) above the flood level rim of the fixture, receptor or device served. No valves shall be installed downstream of the atmospheric vacuum breaker.

    (41) Section 608.15.4.2 is deleted and replaced with the following:

    608.15.4.2 Hose connections. Sillcocks, hose bibbs, wall hydrants and other openings with a hose connection shall be protected by an atmospheric-type or pressure-type vacuum breaker or a permanently attached hose connection vacuum breaker. Add-on-type backflow prevention devices shall be non-removable. In climates where freezing temperatures occur, a listed self-draining frost proof hose bibb with an integral backflow preventer shall be used.

    (42) In Section 608.16.2, the first sentence of the paragraph is deleted and replaced as follows:

    608.16.2 Connections to boilers. The potable water supply to the residential boiler shall be equipped with a backflow preventer with an intermediate atmospheric vent complying with ASSE 1012 or CSA CAN/CSA B64.3.

    (43) Section 608.16.3 is deleted and replaced with the following:

    608.16.3 Heat exchangers. Heat exchangers shall be separated from potable water by double-wall construction. An air gap open to the atmosphere shall be provided between the two walls.

    Exceptions:

    1. Single wall heat exchangers shall be permitted when all of the following conditions are met:

    a. It utilizes a heat transfer medium of potable water or contains only substances which are recognized as safe by the United States Food and Drug Administration (FDA);

    b. The pressure of the heat transfer medium is maintained less than the normal minimum operating pressure of the potable water system; and

    c. The equipment is permanently labeled to indicate only additives recognized as safe by the FDA shall be used.

    2. Steam systems that comply with paragraph 1 above.

    3. Approved listed electrical drinking water coolers.

    (44) In Section 608.16.4.1, add the following exception:

    Exception: All class 1 and 2 systems containing chemical additives consisting of strictly glycerine (C.P. or U.S.P. 96.5 percent grade) or propylene glycol shall be protected against backflow with a double check valve assembly. Such systems shall include written certification of the chemical additives at the time of original installation and service or maintenance.

    (45) Section 608.16.7 is deleted and replaced with the following:

    608.16.7 Chemical dispensers. Where chemical dispensers connect to the water distribution system, the water supply system shall be protected against backflow in accordance with Section 608.13.1, Section 608.13.2, Section 608.13.5, Section 608.13.6 or Section 608.13.8.

    (46) Section 608.16.8 is deleted and replaced with the following:

    608.16.8 Portable cleaning equipment. Where the portable cleaning equipment connects to the water distribution system, the water supply system shall be protected against backflow in accordance with Section 608.13.1, Section 608.13.2 or Section 608.13.8.

    (47) Section 608.16.9 is deleted and replaced with the following:

    608.16.9 Dental pump equipment or water syringe. Where dental pumping equipment or water syringes connects to the water distribution system, the water supply system shall be protected against backflow in accordance with Section 608.13.1, Section 608.13.2, Section 608.13.5, Section 608.13.6 or Section 608.13.8.

    (48) Section 608.16.11 is added as follows:

    608.16.11 Automatic and coin operated car washes. The water supply to an automatic or coin operated car wash shall be protected in accordance with Section 608.13.1 or Section 608.13.2.

    (49) Section 608.17 is deleted in its entirety.

    (50) Section 701.2 is deleted and replaced with the following:

    701.2 Sewer required. Every building in which plumbing fixtures are installed and all premises having drainage piping shall be connected to a public sewer where the sewer is within 300 feet of the property line in accordance with Section 10-8-38, Utah Code Ann., (1953), as amended; or an approved private sewage disposal system in accordance with Rule R317-4, Utah Administrative Code, as administered by the Department of Environmental Quality, Division of Water Quality.

    (51) Section 802.3.2 is deleted in its entirety and replaced with the following:

    802.3.2 Open hub waste receptors. Waste receptors for clear water waste shall be permitted in the form of a hub or pipe extending not more than 1/2 inch above a water impervious floor and are not required to have a strainer.

    (52) Section 901.3 is deleted and replaced with the following:

    901.3 Chemical waste vent system. The vent system for a chemical waste system shall be independent of the sanitary vent system and shall terminate separately through the roof to the open air or to an air admittance valve provided at least one chemical waste vent in the system terminates separately through the roof to the open air.

    ([52]53) Section 904.1 is deleted and replaced with the following:

    904.1 Roof extensions. All open vent pipes that extend through a roof shall be terminated at least 12 inches (304.8 mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extension shall be run at least 7 feet (2134 mm) above the roof.

    ([53]54) In Section 904.6, the following sentence is added at the end of the paragraph:

    Vents extending through the wall shall terminate not less than 12 inches from the wall with an elbow pointing downward.

    ([54]55) In Section 905.4, the following sentence is added at the end of the paragraph:

    Horizontal dry vents below the flood level rim shall be permitted for floor drain and floor sink installations when installed in accordance with Sections 702.2, 905.2 and 905.3 and provided with a wall clean out.

    (56) In Section 917.8 the following exception is added:

    Exception: Air admittance valves shall be permitted in non-neutralized special waste systems provided that they conform to the requirements in Sections 901.3 and 702.5, are tested to ASTM F1412, and are certified by ANSI/ASSE.

    ([55]57) Section 1104.2 is deleted and replaced with the following:

    1104.2 Combining storm and sanitary drainage prohibited. The combining of sanitary and storm drainage systems is prohibited.

    ([56]58) Section 1108 is deleted in its entirety.

    ([57]59) The Referenced Standard NFPA 99c-02 in Chapter 13 is deleted and replaced with NFPA 99c-05.

    ([58]60) The Referenced Standard NSF-2003e in Chapter 13 is amended to add Section 608.11 to the list of Referenced in code section number.

    ([59]61) In Chapter 13, Referenced Standards, the following referenced standard is added:

     

    TABLE

    USC-     Foundation for Cross-Connection  Table 608.1
    FCCCHR Control and Hydraulic Research
    9th University of Southern California
    Edition Kaprielian Hall 300
    Manual Los Angeles CA 90089-2531
    of Cross
    Connection
    Control

     

    ([60]62) Appendix C of the IPC, Gray Water Recycling Systems as amended herein shall not be adopted by any local jurisdiction until such jurisdiction has requested Appendix C as amended to be adopted as a local amendment and such local amendment has been approved as a local amendment under these rules.

    ([61]63) In jurisdictions which have adopted Appendix C as amended as a local amendment as provided herein, Section 301.3 of the IPC is deleted and replaced with the following:

    301.3 Connection to the drainage system. All plumbing fixtures, drains, appurtenances and appliances used to receive or discharge liquid wastes or sewage shall be directly connected to the drainage system of the building or premises, in accordance with the requirements of this Code. This section shall not be construed to prevent indirect waste systems provided for in Chapter 8.

    Exception: Bathtubs, showers, lavatories, clothes washers and laundry sinks shall not be required to discharge to the sanitary drainage system where such fixtures discharge to a gray water recycling system meeting all the requirements as specified in Appendix C as amended by these rules.

    ([62]64) Appendix C is deleted and replaced with the following, to be effective only in jurisdictions which have adopted Appendix C as amended as a local amendment under these rules:

    Appendix C, Gray Water Recycling Systems, C101 Gray Water Recycling Systems

    C101.1 General, recycling gray water within a building. In R1, R2 and R4 occupancies and one- and two-family dwellings, gray water recycling systems are prohibited.

    In commercial occupancies, recycled gray water shall only be utilized for the flushing of water closets and urinals that are located in the same building as the gray water recycling system, provided the following conditions are met:

    1. Such systems comply with Sections C101.1 through C101.14 as amended by these rules.

    2. The commercial establishment demonstrates that it has and will have qualified staff to oversee the gray water recycling systems. Qualified staff is defined as level 3 waste water treatment plan operator as specified by the Department of Environmental Quality.

    3. Gray water recycling systems shall only receive non hazardous waste discharge of bathtubs, showers, lavatories, clothes washers and laundry sinks such as chemicals having a pH of 6.0 to 9.0, or non flammable or non combustible liquids, liquids without objectionable odors, non-highly pigmented liquids, or other liquids that will not interfere with the operation of the sewer treatment facilities.

    C101.2 Permit required. A permit for any gray water recycling system shall not be issued until complete plans prepared by a licensed engineer, with appropriate data satisfactory to the Code Official, have been submitted and approved. No changes or connections shall be made to either the gray water recycling system or the potable water system within any site containing a gray water recycling system, without prior approved by the Code Official. A permit may also be required by the local health department to monitor compliance with this appendix for system operator standards and record keeping.

    C101.3 Definition. The following term shall have the meaning shown herein.

    GRAY WATER. Waste water discharged from lavatories, bathtubs, showers, clothes washers and laundry sinks.

    C101.4 Installation. All drain, waste and vent piping associated with gray water recycling systems shall be installed in full compliance with this code.

    C101.5 Gray Water Reservoir. Gray water shall be collected in an approved reservoir construction of durable, nonabsorbent and corrosion-resistant materials. The reservoir shall be a closed and gas-tight vessel. Gas tight access openings shall be provided to allow inspection and cleaning of the reservoir interior. The holding capacity of the reservoir shall be a minimum of twice the volume of water required to meet the daily flushing requirements of the fixtures supplied by the gray water, but not less than 50 gallons (189 L). The reservoir shall be sized to limit the retention time of gray water to 72 hours maximum.

    C101.6 Filtration. Gray water entering the reservoir shall pass through an approved cartridge filter or other method approved by the Code Official.

    C101.7 Disinfection. Gray water shall be disinfected by an approved method that employs one or more disinfectants such as chlorine, iodine or ozone. A minimum of 1 ppm free residual chlorine shall be maintained in the gray water recycling system reservoir. Such disinfectant shall be automatically dispensed. An alarm shall be provided to shut down the gray water recycling system if disinfectant levels are not maintained at the required levels.

    C101.8 Makeup water. Potable water shall be supplied as a source of makeup water for the gray water recycling system. The potable water supply to any building with a gray water recycling system shall be protected against backflow by an RP backflow assembly installed in accordance with this code. There shall be full-open valve on the makeup water supply to the reservoir. The potable water supply to the gray water reservoir shall be protected by an air gap installed in accordance with this code.

    C101.9 Overflow. The reservoir shall be equipped with an overflow pipe of the same diameter as the influent pipe for the gray water. The overflow shall be directly connected to the sanitary drainage system.

    C101.10 Drain. A drain shall be located at the lowest point of the reservoir and shall be directly connected to the sanitary drainage system. The drain shall be the same diameter as the overflow pipe required by Section C101.9 and shall be provided with a full-open valve.

    C101.11 Vent required. The reservoir shall be provided with a vent sized in accordance with Chapter 9 based on the size of the reservoir influent pipe.

    C101.12 Coloring. The gray water shall be automatically dyed blue or green with a food grade vegetable dye before such water is supplied to the fixtures.

    C101.13 Identification. All gray water distribution piping and reservoirs shall be identified as containing non-potable water. Gray water recycling system piping shall be permanently colored purple or continuously wrapped with purple-colored Mylar tape. The tape or permanently colored piping shall be imprinted in black, upper case letters with the words "CAUTION: GRAY WATER, DO NOT DRINK."

    All equipment areas and rooms for gray water recycling system equipment shall have a sign posted in a conspicuous place with the following text: TO CONSERVE WATER, THIS BUILDING USES GRAY WATER TO FLUSH TOILETS AND URINALS, DO NOT CONNECT TO THE POTABLE WATER SYSTEM. The location of the signage shall be determined by the Code Official.

    C101.14 Removal from service. All gray water recycling systems that are removed from service shall have all connections to the reservoir capped and routed back to the building sewer. All gray water distribution lines shall be replaced with new materials.

    C201.1 Outside the building. Gray water reused outside the building shall comply with the requirements of the Department of Environmental Quality Rule R317.

     

    R156-56-820. Statewide Amendments to the IEBC.

    The following are adopted as amendments to the IEBC to be applicable statewide:

    (1) In Section 101.5 the exception is deleted.

    (2) Section R106.3.2 is deleted and replaced with the following:

    R106.3.2 Previous approval. If a lawful permit has been issued and the construction of which has been pursued in good faith within 180 days after the effective date of the code and has not been abandoned, then the construction may be completed under the code in effect at the time of the issuance of the permit.

    (3) In Section 202 the definition for existing buildings is deleted and replaced with the following:

    EXISTING BUILDING. A building lawfully erected prior to January 1, 2002, or one which is deemed a legal non-conforming building by the code official, and one which is not a dangerous building.

    (4) Section 606.2.2 is deleted and replaced with the following:

    602.2.2 Parapet bracing, wall anchors, and other appendages. Buildings constructed prior to 1975 shall have parapet bracing, wall anchors, and appendages such as cornices, spires, towers, tanks, signs, statuary, etc. evaluated by a licensed engineer when said building is undergoing reroofing, or alteration of or repair to said feature. Such parapet bracing, wall anchors, and appendages shall be evaluated in accordance with the reduced International Building Code level seismic forces as specified in IEBC Section 506.1.1.3 and design procedures of Section 506.1.1.1. When found to be deficient because of design or deteriorated condition, the engineer's [shall prepare specific ]recommendations to anchor, brace, reinforce, or remove the deficient feature shall be implemented.

    EXCEPTIONS:

    1. Group R-3 and U occupancies.

    2. Unreinforced masonry parapets need not be braced according to the above stated provisions provided that the maximum height of an unreinforced masonry parapet above the level of the diaphragm tension anchors or above the parapet braces shall not exceed one and one-half times the thickness of the parapet wall. The parapet height may be a maximum of two and one-half times its thickness in other than Seismic Design Categories D, E, or F.

    (5) Section 705.3.1.2 is deleted and replaced with the following:

    705.3.1.2 Fire escapes required. When more than one exit is required, an existing fire escape complying with Section 705.3.1.2.1 shall be accepted as providing one of the required means of egress.

    705.3.1.2.1 Fire escape access and details. Fire escapes shall comply with all of the following requirements:

    1. Occupants shall have unobstructed access to the fire escapes without having to pass through a room subject to locking.

    2. Access to an existing fire escape shall be through a door, except that windows shall be permitted to provide access from single dwelling units or sleeping units in Group R-1, R-2, and I-1 occupancies or to provide access from spaces having a maximum occupant load of 10 in other occupancy classifications.

    3. Existing fire escapes shall be permitted only where exterior stairs cannot be utilized because of lot lines limiting the stair size or because of the sidewalks, alleys, or roads at grade level.

    4. Openings within 10 feet (3048 mm) of fire escape stairs shall be protected by fire assemblies having minimum 3/4-hour fire-resistance ratings.

    Exception: Opening protection shall not be required in buildings equipped throughout with an approved automatic sprinkler system.

    5. In all buildings of Group E occupancy, up to and including the 12th grade, buildings of Group I occupancy, rooming houses, and childcare centers, ladders of any type are prohibited on fire escapes used as a required means of egress.

    (6) Section 906.1 is deleted and replaced with the following:

    906.1 General. Accessibility in portions of buildings undergoing a change of occupancy classification shall comply with Section 605 and 912.8.

    (7) Section 907.3.1 is deleted and replaced with the following:

    907.3.1 Compliance with the International Building Code. When a building or portion thereof is subject to a change of occupancy such that a change in the nature of the occupancy results in a higher seismic occupancy based on Table 1604.5 of the International Building Code; or where such change of occupancy results in a reclassification of a building to a higher hazard category as shown in Table 912.4; or where a change of a Group M occupancy to a Group A, ETM R-1, R-2, or R-4 occupancy with two-thirds or more of the floors involved in Level 3 alteration work; or when such change of occupancy results in a design occupant load increase of 100% or more, the building shall conform to the seismic requirements of the International Building Code for the new seismic use group.

    Exceptions 1-4 remain unchanged.

    5. Where the design occupant load increase is less than 25 occupants and the occupancy category does not change.

    (8) In Section 912.7.3 exception 2 is deleted.

    (9) In Section 912.8 number 7 is added as follows:

    7. When a change of occupancy in a building or portion of a building results in a Group R-2 occupancy, not less than 20 percent of the dwelling or sleeping units shall be Type B dwelling or sleeping units. These dwelling or sleeping units may be located on any floor of the building provided with an accessible route. Two percent, but not less than one unit, of the dwelling or sleeping units shall be Type A dwelling units.

     

    R156-56-903. Local Amendments to the IPC.

    The following are adopted as amendments to the IPC to be applicable to the following jurisdictions:

    (1) Salt Lake City

    Appendix C of the IPC as specified and amended in R156-56-803(62), (63) and (64).

    ([1]2) South Jordan

    (a) Section 312.9.2 is deleted and replaced with the following:

    312.9.2 Testing. Reduced pressure principle backflow preventer assemblies, double check-valve assemblies, pressure vacuum breaker assemblies, reduced pressure detector fire protection backflow prevention assemblies, double check detector fire protection backflow prevention assemblies, hose connection backflow preventers, and spill-proof vacuum breakers shall be tested at the time of installation, immediately after repairs or relocation and at least annually. The testing procedure shall be performed in accordance with one of the following standards: ASSE 5013, ASSE 5015, ASSE 5020, ASSE 5047, ASSE 5048, ASSE 5052, ASSE 5056, CSA B64.10 or CSA B64.10.1. Assemblies, other than the reduced pressure principle assembly, protecting lawn irrigation systems that fail the annual test shall be replaced with a reduced pressure principle assembly.

    (b) Section 608.16.5 is deleted and replaced with the following:

    608.16.5 Connections to lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by a reduced pressure principle backflow preventer.

     

    KEY: contractors, building codes, building inspection, licensing

    Date of Enactment or Last Substantive Amendment: [July 1, ]2007

    Notice of Continuation: March 29, 2007

    Authorizing, and Implemented or Interpreted Law: 58-1-106(1)(a); 58-1-202(1)(a); 58-56-1; 58-56-4(2); 58-56-6(2)(a); 58-56-18

     

Document Information

Effective Date:
12/10/2007
Publication Date:
11/01/2007
Filed Date:
10/11/2007
Agencies:
Commerce,Occupational and Professional Licensing
Rulemaking Authority:

Section 58-56-1 and Subsections 58-1-106(1)(a), 58-1-202(1)(a), 58-56-4(2), and 58-56-6(2)(a)

Authorized By:
F. David Stanley, Director
DAR File No.:
30574
Related Chapter/Rule NO.: (1)
R156-56. Utah Uniform Building Standard Act Rules.